Metrological analysis of laser active control devices of details dimensions using corundum tips

The article is devoted to calculation of measurement error of contact of active control devices (ACD) of product dimensions using artificially created corundum tips. It is shown that most of it is determined by the temperature error that occurs due to its thermal expansion of the tip when heated...

Full description

Saved in:
Bibliographic Details
Main Authors: E. V. Leun, V. I. Leun, A. E. Shahanov
Format: Article
Language:English
Published: Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education 2018-04-01
Series:Омский научный вестник
Subjects:
Online Access:https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/2%20(158)/98-104%20%D0%9B%D0%B5%D1%83%D0%BD%20%D0%95.%20%D0%92.,%20%D0%9B%D0%B5%D1%83%D0%BD%20%D0%92.%20%D0%98.,%20%D0%A8%D0%B0%D1%85%D0%B0%D0%BD%D0%BE%D0%B2%20%D0%90.%20%D0%95..pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832573659682701312
author E. V. Leun
V. I. Leun
A. E. Shahanov
author_facet E. V. Leun
V. I. Leun
A. E. Shahanov
author_sort E. V. Leun
collection DOAJ
description The article is devoted to calculation of measurement error of contact of active control devices (ACD) of product dimensions using artificially created corundum tips. It is shown that most of it is determined by the temperature error that occurs due to its thermal expansion of the tip when heated as a result of mechanical contact with the detail. The calculations are based on the formation in the tip of the route of the input and reflected optical flows at an angle to its front surface providing a complete internal reflection in the contact area with the detail. The calculation of measurement error is made when creating a reference channel in the laser interferometer, fixing the displacement of the back side of the tip from its thermal expansion. A significant reduction of measurement error for this case is shown.
format Article
id doaj-art-eb812e80817e4f9f952f7596f565808d
institution Kabale University
issn 1813-8225
2541-7541
language English
publishDate 2018-04-01
publisher Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
record_format Article
series Омский научный вестник
spelling doaj-art-eb812e80817e4f9f952f7596f565808d2025-02-02T03:33:56ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412018-04-012 (158)9810410.25206/1813-8225-2018-158-98-104Metrological analysis of laser active control devices of details dimensions using corundum tipsE. V. Leun0V. I. Leun1A. E. Shahanov2Lavochkin AssociationOmsk State Technical UniversityLavochkin AssociationThe article is devoted to calculation of measurement error of contact of active control devices (ACD) of product dimensions using artificially created corundum tips. It is shown that most of it is determined by the temperature error that occurs due to its thermal expansion of the tip when heated as a result of mechanical contact with the detail. The calculations are based on the formation in the tip of the route of the input and reflected optical flows at an angle to its front surface providing a complete internal reflection in the contact area with the detail. The calculation of measurement error is made when creating a reference channel in the laser interferometer, fixing the displacement of the back side of the tip from its thermal expansion. A significant reduction of measurement error for this case is shown.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/2%20(158)/98-104%20%D0%9B%D0%B5%D1%83%D0%BD%20%D0%95.%20%D0%92.,%20%D0%9B%D0%B5%D1%83%D0%BD%20%D0%92.%20%D0%98.,%20%D0%A8%D0%B0%D1%85%D0%B0%D0%BD%D0%BE%D0%B2%20%D0%90.%20%D0%95..pdfactive control devicecorundum tipthermal expansion of the tipthe tip wearmeasurement errorlaser interferometer
spellingShingle E. V. Leun
V. I. Leun
A. E. Shahanov
Metrological analysis of laser active control devices of details dimensions using corundum tips
Омский научный вестник
active control device
corundum tip
thermal expansion of the tip
the tip wear
measurement error
laser interferometer
title Metrological analysis of laser active control devices of details dimensions using corundum tips
title_full Metrological analysis of laser active control devices of details dimensions using corundum tips
title_fullStr Metrological analysis of laser active control devices of details dimensions using corundum tips
title_full_unstemmed Metrological analysis of laser active control devices of details dimensions using corundum tips
title_short Metrological analysis of laser active control devices of details dimensions using corundum tips
title_sort metrological analysis of laser active control devices of details dimensions using corundum tips
topic active control device
corundum tip
thermal expansion of the tip
the tip wear
measurement error
laser interferometer
url https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/2%20(158)/98-104%20%D0%9B%D0%B5%D1%83%D0%BD%20%D0%95.%20%D0%92.,%20%D0%9B%D0%B5%D1%83%D0%BD%20%D0%92.%20%D0%98.,%20%D0%A8%D0%B0%D1%85%D0%B0%D0%BD%D0%BE%D0%B2%20%D0%90.%20%D0%95..pdf
work_keys_str_mv AT evleun metrologicalanalysisoflaseractivecontroldevicesofdetailsdimensionsusingcorundumtips
AT vileun metrologicalanalysisoflaseractivecontroldevicesofdetailsdimensionsusingcorundumtips
AT aeshahanov metrologicalanalysisoflaseractivecontroldevicesofdetailsdimensionsusingcorundumtips