A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed Depot
As an importance strategy to finance the transport infrastructure investment, transit-oriented development (TOD) for railway depot is rapidly growing in China. However, railway-induced noise emerged as the leading environmental nuisance triggering one of the most common public complaints. In order t...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2022-01-01
|
Series: | Advances in Civil Engineering |
Online Access: | http://dx.doi.org/10.1155/2022/3173567 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832554869212315648 |
---|---|
author | Qiang Liu Zhongxu Kang Hougui Zhang Ruixiang Song Ge Li |
author_facet | Qiang Liu Zhongxu Kang Hougui Zhang Ruixiang Song Ge Li |
author_sort | Qiang Liu |
collection | DOAJ |
description | As an importance strategy to finance the transport infrastructure investment, transit-oriented development (TOD) for railway depot is rapidly growing in China. However, railway-induced noise emerged as the leading environmental nuisance triggering one of the most common public complaints. In order to discuss the influence of railway-induced noise on the neighbourhood residents in a TOD developed depot, a special case study is provided in this study. Measurement campaigns were conducted for responding to the complaints, and noise map was calculated for finding out a noise control solution. Based on the recommendation awakening threshold value of 42 dB (A) summarized from the Night Noise Guidelines for Europe (WHO, 2009), the measurement results confirmed that the neighbourhood residents were indeed suffering from the instantaneous railway noise, and the sleep disturbance correlated indicator LAmax was more than 56 dB (A) at outside of buildings. Furthermore, calculation results indicated that the lower office buildings became mirrors which reflected the noise across over the cover structure to the higher stories of residents’ buildings. At the ends, a kind of dissipative splitter muffler was proposed as a potential solution, and its performance was also simulated. |
format | Article |
id | doaj-art-eb368c7e387f44b3825a245a8c82179a |
institution | Kabale University |
issn | 1687-8094 |
language | English |
publishDate | 2022-01-01 |
publisher | Wiley |
record_format | Article |
series | Advances in Civil Engineering |
spelling | doaj-art-eb368c7e387f44b3825a245a8c82179a2025-02-03T05:50:17ZengWileyAdvances in Civil Engineering1687-80942022-01-01202210.1155/2022/3173567A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed DepotQiang Liu0Zhongxu Kang1Hougui Zhang2Ruixiang Song3Ge Li4Institute of Urban Safety and Environment ScienceInstitute of Urban Safety and Environment ScienceInstitute of Urban Safety and Environment ScienceInstitute of Urban Safety and Environment ScienceInstitute of Urban Safety and Environment ScienceAs an importance strategy to finance the transport infrastructure investment, transit-oriented development (TOD) for railway depot is rapidly growing in China. However, railway-induced noise emerged as the leading environmental nuisance triggering one of the most common public complaints. In order to discuss the influence of railway-induced noise on the neighbourhood residents in a TOD developed depot, a special case study is provided in this study. Measurement campaigns were conducted for responding to the complaints, and noise map was calculated for finding out a noise control solution. Based on the recommendation awakening threshold value of 42 dB (A) summarized from the Night Noise Guidelines for Europe (WHO, 2009), the measurement results confirmed that the neighbourhood residents were indeed suffering from the instantaneous railway noise, and the sleep disturbance correlated indicator LAmax was more than 56 dB (A) at outside of buildings. Furthermore, calculation results indicated that the lower office buildings became mirrors which reflected the noise across over the cover structure to the higher stories of residents’ buildings. At the ends, a kind of dissipative splitter muffler was proposed as a potential solution, and its performance was also simulated.http://dx.doi.org/10.1155/2022/3173567 |
spellingShingle | Qiang Liu Zhongxu Kang Hougui Zhang Ruixiang Song Ge Li A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed Depot Advances in Civil Engineering |
title | A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed Depot |
title_full | A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed Depot |
title_fullStr | A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed Depot |
title_full_unstemmed | A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed Depot |
title_short | A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed Depot |
title_sort | case study on annoyance noise caused by metro railway at a tod developed depot |
url | http://dx.doi.org/10.1155/2022/3173567 |
work_keys_str_mv | AT qiangliu acasestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot AT zhongxukang acasestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot AT houguizhang acasestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot AT ruixiangsong acasestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot AT geli acasestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot AT qiangliu casestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot AT zhongxukang casestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot AT houguizhang casestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot AT ruixiangsong casestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot AT geli casestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot |