A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed Depot

As an importance strategy to finance the transport infrastructure investment, transit-oriented development (TOD) for railway depot is rapidly growing in China. However, railway-induced noise emerged as the leading environmental nuisance triggering one of the most common public complaints. In order t...

Full description

Saved in:
Bibliographic Details
Main Authors: Qiang Liu, Zhongxu Kang, Hougui Zhang, Ruixiang Song, Ge Li
Format: Article
Language:English
Published: Wiley 2022-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2022/3173567
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832554869212315648
author Qiang Liu
Zhongxu Kang
Hougui Zhang
Ruixiang Song
Ge Li
author_facet Qiang Liu
Zhongxu Kang
Hougui Zhang
Ruixiang Song
Ge Li
author_sort Qiang Liu
collection DOAJ
description As an importance strategy to finance the transport infrastructure investment, transit-oriented development (TOD) for railway depot is rapidly growing in China. However, railway-induced noise emerged as the leading environmental nuisance triggering one of the most common public complaints. In order to discuss the influence of railway-induced noise on the neighbourhood residents in a TOD developed depot, a special case study is provided in this study. Measurement campaigns were conducted for responding to the complaints, and noise map was calculated for finding out a noise control solution. Based on the recommendation awakening threshold value of 42 dB (A) summarized from the Night Noise Guidelines for Europe (WHO, 2009), the measurement results confirmed that the neighbourhood residents were indeed suffering from the instantaneous railway noise, and the sleep disturbance correlated indicator LAmax was more than 56 dB (A) at outside of buildings. Furthermore, calculation results indicated that the lower office buildings became mirrors which reflected the noise across over the cover structure to the higher stories of residents’ buildings. At the ends, a kind of dissipative splitter muffler was proposed as a potential solution, and its performance was also simulated.
format Article
id doaj-art-eb368c7e387f44b3825a245a8c82179a
institution Kabale University
issn 1687-8094
language English
publishDate 2022-01-01
publisher Wiley
record_format Article
series Advances in Civil Engineering
spelling doaj-art-eb368c7e387f44b3825a245a8c82179a2025-02-03T05:50:17ZengWileyAdvances in Civil Engineering1687-80942022-01-01202210.1155/2022/3173567A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed DepotQiang Liu0Zhongxu Kang1Hougui Zhang2Ruixiang Song3Ge Li4Institute of Urban Safety and Environment ScienceInstitute of Urban Safety and Environment ScienceInstitute of Urban Safety and Environment ScienceInstitute of Urban Safety and Environment ScienceInstitute of Urban Safety and Environment ScienceAs an importance strategy to finance the transport infrastructure investment, transit-oriented development (TOD) for railway depot is rapidly growing in China. However, railway-induced noise emerged as the leading environmental nuisance triggering one of the most common public complaints. In order to discuss the influence of railway-induced noise on the neighbourhood residents in a TOD developed depot, a special case study is provided in this study. Measurement campaigns were conducted for responding to the complaints, and noise map was calculated for finding out a noise control solution. Based on the recommendation awakening threshold value of 42 dB (A) summarized from the Night Noise Guidelines for Europe (WHO, 2009), the measurement results confirmed that the neighbourhood residents were indeed suffering from the instantaneous railway noise, and the sleep disturbance correlated indicator LAmax was more than 56 dB (A) at outside of buildings. Furthermore, calculation results indicated that the lower office buildings became mirrors which reflected the noise across over the cover structure to the higher stories of residents’ buildings. At the ends, a kind of dissipative splitter muffler was proposed as a potential solution, and its performance was also simulated.http://dx.doi.org/10.1155/2022/3173567
spellingShingle Qiang Liu
Zhongxu Kang
Hougui Zhang
Ruixiang Song
Ge Li
A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed Depot
Advances in Civil Engineering
title A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed Depot
title_full A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed Depot
title_fullStr A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed Depot
title_full_unstemmed A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed Depot
title_short A Case Study on Annoyance Noise Caused by Metro Railway at a TOD Developed Depot
title_sort case study on annoyance noise caused by metro railway at a tod developed depot
url http://dx.doi.org/10.1155/2022/3173567
work_keys_str_mv AT qiangliu acasestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot
AT zhongxukang acasestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot
AT houguizhang acasestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot
AT ruixiangsong acasestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot
AT geli acasestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot
AT qiangliu casestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot
AT zhongxukang casestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot
AT houguizhang casestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot
AT ruixiangsong casestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot
AT geli casestudyonannoyancenoisecausedbymetrorailwayatatoddevelopeddepot