ANALYSIS AND VALIDATION OF DETECTION METHOD FOR ETHYLENE AND DIETHYLENE GLYCOL CONTAMINANTS IN SYRUP USING GCMS (GAS CHROMATOGRAPHY-MASS SPECTROMETER)

Ethylene glycol (EG) and diethylene glycol (DEG) are hazardous compounds if ingested by the human body. Testing conducted by the Indonesian National Agency of Drug and Food Control (BPM) identified contamination of EG and DEG in glycerin and propylene glycol, which are utilized as solubility enhanc...