Parameter Design and Stability Analysis of Double-Loop Control for High-speed EMU 4QS-Converter

Double-grid-frequency fluctuation exists in DC-link voltage of EMU 4QS-converter whose grid-side current contains much ripple of equivalent switching frequency. RC circuit filters and digital filters were usually employed for signal conditioning of voltage and current. However, improper filter param...

Full description

Saved in:
Bibliographic Details
Main Authors: Yue WANG, Gang FU, Jingyu HU, Yun PENG, Zhixue ZHANG
Format: Article
Language:zho
Published: Editorial Department of Electric Drive for Locomotives 2020-03-01
Series:机车电传动
Subjects:
Online Access:http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128x.2020.02.006
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849728739862118400
author Yue WANG
Gang FU
Jingyu HU
Yun PENG
Zhixue ZHANG
author_facet Yue WANG
Gang FU
Jingyu HU
Yun PENG
Zhixue ZHANG
author_sort Yue WANG
collection DOAJ
description Double-grid-frequency fluctuation exists in DC-link voltage of EMU 4QS-converter whose grid-side current contains much ripple of equivalent switching frequency. RC circuit filters and digital filters were usually employed for signal conditioning of voltage and current. However, improper filter parameter will lead to unstable control. In order to improve control stability of 400 km/h high-speed EMU, firstly, the parameter design principle of DC-link voltage and current double-loop control for a 4QS-converter was introduced. Secondly, the effects of voltage and current signal conditioning filters on the stability of the double-loop control were analyzed, and the necessary conditions of system stable were revealed. Finally, simulation results based on 400 km/h high-speed EMU verifiedied the correctness and effectiveness of the theoretical analysis.
format Article
id doaj-art-e95694900f124c5ea317743797fe65b8
institution DOAJ
issn 1000-128X
language zho
publishDate 2020-03-01
publisher Editorial Department of Electric Drive for Locomotives
record_format Article
series 机车电传动
spelling doaj-art-e95694900f124c5ea317743797fe65b82025-08-20T03:09:27ZzhoEditorial Department of Electric Drive for Locomotives机车电传动1000-128X2020-03-012630,6620921465Parameter Design and Stability Analysis of Double-Loop Control for High-speed EMU 4QS-ConverterYue WANGGang FUJingyu HUYun PENGZhixue ZHANGDouble-grid-frequency fluctuation exists in DC-link voltage of EMU 4QS-converter whose grid-side current contains much ripple of equivalent switching frequency. RC circuit filters and digital filters were usually employed for signal conditioning of voltage and current. However, improper filter parameter will lead to unstable control. In order to improve control stability of 400 km/h high-speed EMU, firstly, the parameter design principle of DC-link voltage and current double-loop control for a 4QS-converter was introduced. Secondly, the effects of voltage and current signal conditioning filters on the stability of the double-loop control were analyzed, and the necessary conditions of system stable were revealed. Finally, simulation results based on 400 km/h high-speed EMU verifiedied the correctness and effectiveness of the theoretical analysis.http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128x.2020.02.006high-speed EMU4QS-converterdouble-loop controlparameter designfilter time constantintegral time constantstability analysissimulation
spellingShingle Yue WANG
Gang FU
Jingyu HU
Yun PENG
Zhixue ZHANG
Parameter Design and Stability Analysis of Double-Loop Control for High-speed EMU 4QS-Converter
机车电传动
high-speed EMU
4QS-converter
double-loop control
parameter design
filter time constant
integral time constant
stability analysis
simulation
title Parameter Design and Stability Analysis of Double-Loop Control for High-speed EMU 4QS-Converter
title_full Parameter Design and Stability Analysis of Double-Loop Control for High-speed EMU 4QS-Converter
title_fullStr Parameter Design and Stability Analysis of Double-Loop Control for High-speed EMU 4QS-Converter
title_full_unstemmed Parameter Design and Stability Analysis of Double-Loop Control for High-speed EMU 4QS-Converter
title_short Parameter Design and Stability Analysis of Double-Loop Control for High-speed EMU 4QS-Converter
title_sort parameter design and stability analysis of double loop control for high speed emu 4qs converter
topic high-speed EMU
4QS-converter
double-loop control
parameter design
filter time constant
integral time constant
stability analysis
simulation
url http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128x.2020.02.006
work_keys_str_mv AT yuewang parameterdesignandstabilityanalysisofdoubleloopcontrolforhighspeedemu4qsconverter
AT gangfu parameterdesignandstabilityanalysisofdoubleloopcontrolforhighspeedemu4qsconverter
AT jingyuhu parameterdesignandstabilityanalysisofdoubleloopcontrolforhighspeedemu4qsconverter
AT yunpeng parameterdesignandstabilityanalysisofdoubleloopcontrolforhighspeedemu4qsconverter
AT zhixuezhang parameterdesignandstabilityanalysisofdoubleloopcontrolforhighspeedemu4qsconverter