Comparison of positive expiratory pressure device versus non-invasive ventilation on outcomes in acute exacerbation of chronic obstructive pulmonary disease in the emergency department

Abstract Background Acute exacerbations of chronic obstructive pulmonary disease (COPD) are among the most common reasons for emergency department visits. In patients who develop hypercapnic respiratory failure, non-invasive mechanical ventilation (NIV) is generally the preferred treatment. However,...

Full description

Saved in:
Bibliographic Details
Main Authors: Emine Sarcan, Ahmet Burak Erdem, Merve Yazla, Şerife Büşra Uysal, Elif Çelikel
Format: Article
Language:English
Published: BMC 2025-07-01
Series:BMC Emergency Medicine
Subjects:
Online Access:https://doi.org/10.1186/s12873-025-01267-z
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849402937296551936
author Emine Sarcan
Ahmet Burak Erdem
Merve Yazla
Şerife Büşra Uysal
Elif Çelikel
author_facet Emine Sarcan
Ahmet Burak Erdem
Merve Yazla
Şerife Büşra Uysal
Elif Çelikel
author_sort Emine Sarcan
collection DOAJ
description Abstract Background Acute exacerbations of chronic obstructive pulmonary disease (COPD) are among the most common reasons for emergency department visits. In patients who develop hypercapnic respiratory failure, non-invasive mechanical ventilation (NIV) is generally the preferred treatment. However, in overcrowded emergency departments, the number of mechanical ventilation devices may be insufficient. In such situations, positive expiratory pressure (PEP) devices can be utilized. This study aims to evaluate the clinical efficacy of the PEP device (EzPAP®) compared to NIV for the management of exacerbations of COPD in the emergency department. Methods This prospective, randomized controlled study was conducted on 103 patients who presented to the emergency department with exacerbations of COPD and acute hypercapnic respiratory failure between November 2023 and April 2024. Patients were divided into two groups: EzPAP® (E) and NIV (N). Spirometric parameters, arterial blood gas values, hospital admission rates, and 30-day mortality rates were compared before and after treatment in both groups. Results A total of 103 patients were included in the study (N: 49, E: 54). In Group N, no statistically significant increase was observed in FEV₁ and FVC after treatment (p = 0.120). A statistically significant increase in FEV₁ and FVC was detected in the EzPAP group (p < 0.001). An increase in oxygen saturation and an improvement in PaCO₂ and lactate levels were observed in both groups (p < 0.001). The difference in blood gas values before and after treatment (delta = Δ) was not statistically significant between the two groups. However, ΔFEV₁ and ΔFVC were significantly higher in the EzPAP group compared to the NIV group (p = 0.007, p = 0.022). The hospital admission rate was higher in the NIV group than in the EzPAP® group (p = 0.04). Conclusion EzPAP® may be a suitable option for use in overcrowded emergency departments, as it demonstrates efficacy comparable to NIV in the management of exacerbations in COPD. Additionally, it can also be considered as a treatment alternative in situations where the number of mechanical ventilation devices for NIV is insufficient, such as during a pandemic. Trial registration ClinicalTrials Number: NCT06561464 Registration Date: 07/08/2024.
format Article
id doaj-art-e94c4a8d03b04b2c954ce497b1055d9c
institution Kabale University
issn 1471-227X
language English
publishDate 2025-07-01
publisher BMC
record_format Article
series BMC Emergency Medicine
spelling doaj-art-e94c4a8d03b04b2c954ce497b1055d9c2025-08-20T03:37:23ZengBMCBMC Emergency Medicine1471-227X2025-07-0125111010.1186/s12873-025-01267-zComparison of positive expiratory pressure device versus non-invasive ventilation on outcomes in acute exacerbation of chronic obstructive pulmonary disease in the emergency departmentEmine Sarcan0Ahmet Burak Erdem1Merve Yazla2Şerife Büşra Uysal3Elif Çelikel4Department of Emergency Medicine, Ministry of Health Ankara Etlik City HospitalDepartment of Emergency Medicine, Ministry of Health Ankara Etlik City HospitalDepartment of Emergency Medicine, Ministry of Health Ankara Etlik City HospitalDepartment of Emergency Medicine, Ministry of Health Ankara Etlik City HospitalDepartment of Emergency Medicine, Ministry of Health Ankara Etlik City HospitalAbstract Background Acute exacerbations of chronic obstructive pulmonary disease (COPD) are among the most common reasons for emergency department visits. In patients who develop hypercapnic respiratory failure, non-invasive mechanical ventilation (NIV) is generally the preferred treatment. However, in overcrowded emergency departments, the number of mechanical ventilation devices may be insufficient. In such situations, positive expiratory pressure (PEP) devices can be utilized. This study aims to evaluate the clinical efficacy of the PEP device (EzPAP®) compared to NIV for the management of exacerbations of COPD in the emergency department. Methods This prospective, randomized controlled study was conducted on 103 patients who presented to the emergency department with exacerbations of COPD and acute hypercapnic respiratory failure between November 2023 and April 2024. Patients were divided into two groups: EzPAP® (E) and NIV (N). Spirometric parameters, arterial blood gas values, hospital admission rates, and 30-day mortality rates were compared before and after treatment in both groups. Results A total of 103 patients were included in the study (N: 49, E: 54). In Group N, no statistically significant increase was observed in FEV₁ and FVC after treatment (p = 0.120). A statistically significant increase in FEV₁ and FVC was detected in the EzPAP group (p < 0.001). An increase in oxygen saturation and an improvement in PaCO₂ and lactate levels were observed in both groups (p < 0.001). The difference in blood gas values before and after treatment (delta = Δ) was not statistically significant between the two groups. However, ΔFEV₁ and ΔFVC were significantly higher in the EzPAP group compared to the NIV group (p = 0.007, p = 0.022). The hospital admission rate was higher in the NIV group than in the EzPAP® group (p = 0.04). Conclusion EzPAP® may be a suitable option for use in overcrowded emergency departments, as it demonstrates efficacy comparable to NIV in the management of exacerbations in COPD. Additionally, it can also be considered as a treatment alternative in situations where the number of mechanical ventilation devices for NIV is insufficient, such as during a pandemic. Trial registration ClinicalTrials Number: NCT06561464 Registration Date: 07/08/2024.https://doi.org/10.1186/s12873-025-01267-zChronic obstructive pulmonary diseaseNon-invasive ventilationEzPAP®Hypercapnic respiratory failure
spellingShingle Emine Sarcan
Ahmet Burak Erdem
Merve Yazla
Şerife Büşra Uysal
Elif Çelikel
Comparison of positive expiratory pressure device versus non-invasive ventilation on outcomes in acute exacerbation of chronic obstructive pulmonary disease in the emergency department
BMC Emergency Medicine
Chronic obstructive pulmonary disease
Non-invasive ventilation
EzPAP®
Hypercapnic respiratory failure
title Comparison of positive expiratory pressure device versus non-invasive ventilation on outcomes in acute exacerbation of chronic obstructive pulmonary disease in the emergency department
title_full Comparison of positive expiratory pressure device versus non-invasive ventilation on outcomes in acute exacerbation of chronic obstructive pulmonary disease in the emergency department
title_fullStr Comparison of positive expiratory pressure device versus non-invasive ventilation on outcomes in acute exacerbation of chronic obstructive pulmonary disease in the emergency department
title_full_unstemmed Comparison of positive expiratory pressure device versus non-invasive ventilation on outcomes in acute exacerbation of chronic obstructive pulmonary disease in the emergency department
title_short Comparison of positive expiratory pressure device versus non-invasive ventilation on outcomes in acute exacerbation of chronic obstructive pulmonary disease in the emergency department
title_sort comparison of positive expiratory pressure device versus non invasive ventilation on outcomes in acute exacerbation of chronic obstructive pulmonary disease in the emergency department
topic Chronic obstructive pulmonary disease
Non-invasive ventilation
EzPAP®
Hypercapnic respiratory failure
url https://doi.org/10.1186/s12873-025-01267-z
work_keys_str_mv AT eminesarcan comparisonofpositiveexpiratorypressuredeviceversusnoninvasiveventilationonoutcomesinacuteexacerbationofchronicobstructivepulmonarydiseaseintheemergencydepartment
AT ahmetburakerdem comparisonofpositiveexpiratorypressuredeviceversusnoninvasiveventilationonoutcomesinacuteexacerbationofchronicobstructivepulmonarydiseaseintheemergencydepartment
AT merveyazla comparisonofpositiveexpiratorypressuredeviceversusnoninvasiveventilationonoutcomesinacuteexacerbationofchronicobstructivepulmonarydiseaseintheemergencydepartment
AT serifebusrauysal comparisonofpositiveexpiratorypressuredeviceversusnoninvasiveventilationonoutcomesinacuteexacerbationofchronicobstructivepulmonarydiseaseintheemergencydepartment
AT elifcelikel comparisonofpositiveexpiratorypressuredeviceversusnoninvasiveventilationonoutcomesinacuteexacerbationofchronicobstructivepulmonarydiseaseintheemergencydepartment