A Case Report of Implant Fracture of Extensively Porous-Coated, Distally Fixated Cementless Long Stem: Detailed Course of Stem Bending Development

We report the fracture of a cementless long stem in a distally fixated, extensively porous-coated femoral prosthesis used for revisional total hip arthroplasty (THA) 9 years previously in a 48-year-old woman, measuring 58 kg in weight and 155 cm in height. Following resolution of an infection 7 year...

Full description

Saved in:
Bibliographic Details
Main Author: Tomohiro Mimura
Format: Article
Language:English
Published: Wiley 2015-01-01
Series:Case Reports in Orthopedics
Online Access:http://dx.doi.org/10.1155/2015/895214
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850164653489913856
author Tomohiro Mimura
author_facet Tomohiro Mimura
author_sort Tomohiro Mimura
collection DOAJ
description We report the fracture of a cementless long stem in a distally fixated, extensively porous-coated femoral prosthesis used for revisional total hip arthroplasty (THA) 9 years previously in a 48-year-old woman, measuring 58 kg in weight and 155 cm in height. Following resolution of an infection 7 years after the revisional THA, a series of posterior dislocations occurred up until 7 months before sudden stem fracture. Extensive radiographic imaging evidence indicated a gradual progression of bending in the stem, and scanning electron microscope energy dispersive X-ray spectroscopy revealed oxygen in the medial and lateral sections, suspecting in vivo corrosion. We retrospectively examined the detailed course of stem bending development prior to stem fracture. The stem bending immediately after the revisional THA, at the first dislocation, and immediately before the stem fracture was 0°, 1.9°, and 5.2°, respectively. We consider that the cyclic loading with poor proximal bone support, distal fixation, and small diameter were the potential risk of this implant fracture. However, the course of stem bending development suggested that repeated operations and several dislocations might have aggravated the implant fatigue in the present case.
format Article
id doaj-art-e8cf460450bc4961a61d0a83dd75d644
institution OA Journals
issn 2090-6749
2090-6757
language English
publishDate 2015-01-01
publisher Wiley
record_format Article
series Case Reports in Orthopedics
spelling doaj-art-e8cf460450bc4961a61d0a83dd75d6442025-08-20T02:21:57ZengWileyCase Reports in Orthopedics2090-67492090-67572015-01-01201510.1155/2015/895214895214A Case Report of Implant Fracture of Extensively Porous-Coated, Distally Fixated Cementless Long Stem: Detailed Course of Stem Bending DevelopmentTomohiro Mimura0Department of Orthopedics Surgery, Shiga University of Medical Science, Shiga 520-2192, JapanWe report the fracture of a cementless long stem in a distally fixated, extensively porous-coated femoral prosthesis used for revisional total hip arthroplasty (THA) 9 years previously in a 48-year-old woman, measuring 58 kg in weight and 155 cm in height. Following resolution of an infection 7 years after the revisional THA, a series of posterior dislocations occurred up until 7 months before sudden stem fracture. Extensive radiographic imaging evidence indicated a gradual progression of bending in the stem, and scanning electron microscope energy dispersive X-ray spectroscopy revealed oxygen in the medial and lateral sections, suspecting in vivo corrosion. We retrospectively examined the detailed course of stem bending development prior to stem fracture. The stem bending immediately after the revisional THA, at the first dislocation, and immediately before the stem fracture was 0°, 1.9°, and 5.2°, respectively. We consider that the cyclic loading with poor proximal bone support, distal fixation, and small diameter were the potential risk of this implant fracture. However, the course of stem bending development suggested that repeated operations and several dislocations might have aggravated the implant fatigue in the present case.http://dx.doi.org/10.1155/2015/895214
spellingShingle Tomohiro Mimura
A Case Report of Implant Fracture of Extensively Porous-Coated, Distally Fixated Cementless Long Stem: Detailed Course of Stem Bending Development
Case Reports in Orthopedics
title A Case Report of Implant Fracture of Extensively Porous-Coated, Distally Fixated Cementless Long Stem: Detailed Course of Stem Bending Development
title_full A Case Report of Implant Fracture of Extensively Porous-Coated, Distally Fixated Cementless Long Stem: Detailed Course of Stem Bending Development
title_fullStr A Case Report of Implant Fracture of Extensively Porous-Coated, Distally Fixated Cementless Long Stem: Detailed Course of Stem Bending Development
title_full_unstemmed A Case Report of Implant Fracture of Extensively Porous-Coated, Distally Fixated Cementless Long Stem: Detailed Course of Stem Bending Development
title_short A Case Report of Implant Fracture of Extensively Porous-Coated, Distally Fixated Cementless Long Stem: Detailed Course of Stem Bending Development
title_sort case report of implant fracture of extensively porous coated distally fixated cementless long stem detailed course of stem bending development
url http://dx.doi.org/10.1155/2015/895214
work_keys_str_mv AT tomohiromimura acasereportofimplantfractureofextensivelyporouscoateddistallyfixatedcementlesslongstemdetailedcourseofstembendingdevelopment
AT tomohiromimura casereportofimplantfractureofextensivelyporouscoateddistallyfixatedcementlesslongstemdetailedcourseofstembendingdevelopment