Achievement of 15-Minute Adaptive PCR Benchmark with 1370 nm Laser Heating

In low-resource and point-of-care settings, traditional PCR often faces challenges of poor sample preparation, adverse environmental conditions, and long assay times. We have previously described a laboratory-based instrument to achieve “adaptive” PCR, a PCR thermocycling control system that replace...

Full description

Saved in:
Bibliographic Details
Main Authors: Nicholas Spurlock, Rosana Alfaro, William E. Gabella, Kunal Chugh, Megan E. Pask, Franz Baudenbacher, Frederick R. Haselton
Format: Article
Language:English
Published: MDPI AG 2025-04-01
Series:Biosensors
Subjects:
Online Access:https://www.mdpi.com/2079-6374/15/4/258
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850183236242636800
author Nicholas Spurlock
Rosana Alfaro
William E. Gabella
Kunal Chugh
Megan E. Pask
Franz Baudenbacher
Frederick R. Haselton
author_facet Nicholas Spurlock
Rosana Alfaro
William E. Gabella
Kunal Chugh
Megan E. Pask
Franz Baudenbacher
Frederick R. Haselton
author_sort Nicholas Spurlock
collection DOAJ
description In low-resource and point-of-care settings, traditional PCR often faces challenges of poor sample preparation, adverse environmental conditions, and long assay times. We have previously described a laboratory-based instrument to achieve “adaptive” PCR, a PCR thermocycling control system that replaces preset cycling times and temperatures with the optical monitoring of added L-DNA stereoisomers matching the sequences of the reaction primers and target. These L-DNA biosensors directly monitor DNA hybridization, compensating for ambient environmental conditions and poor sample preparation. This report describes instrument simplifications and a comparative evaluation of both direct photothermal and plasmonic laser heating to reduce the assay time to 15 min. Instrument performance was assessed using a split sample design to compare reaction performances of 1370 and 808 nm adaptive PCR heating modalities to a standard PCR instrument. Both the novel 1370 nm direct heating and the 808 nm plasmonic method achieved target amplification similar to the traditional PCR system within 15 min. However, a major disadvantage of 808 nm heating was nanorod optical interference that reduced the fluorescence signal from PCR probes and optical cycling components. Further characterization of the 1370 nm direct heating method found comparable limits of detection of 10<sup>0</sup> copies/µL and reaction efficiencies of approximately 2 for both the 1370 nm system and the traditional PCR instrument. These results suggest that a field-deployable PCR instrument design incorporating both adaptive optical control and 1370 nm laser heating can achieve 15 min sample assay times without sacrificing analytical sensitivity.
format Article
id doaj-art-e8c8f8e2fa954699a4f4905aeb6f062e
institution OA Journals
issn 2079-6374
language English
publishDate 2025-04-01
publisher MDPI AG
record_format Article
series Biosensors
spelling doaj-art-e8c8f8e2fa954699a4f4905aeb6f062e2025-08-20T02:17:25ZengMDPI AGBiosensors2079-63742025-04-0115425810.3390/bios15040258Achievement of 15-Minute Adaptive PCR Benchmark with 1370 nm Laser HeatingNicholas Spurlock0Rosana Alfaro1William E. Gabella2Kunal Chugh3Megan E. Pask4Franz Baudenbacher5Frederick R. Haselton6Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USADepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USADepartment of Physics and Astronomy, Vanderbilt University, Nashville, TN 37235, USADepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USADepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USADepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USADepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USAIn low-resource and point-of-care settings, traditional PCR often faces challenges of poor sample preparation, adverse environmental conditions, and long assay times. We have previously described a laboratory-based instrument to achieve “adaptive” PCR, a PCR thermocycling control system that replaces preset cycling times and temperatures with the optical monitoring of added L-DNA stereoisomers matching the sequences of the reaction primers and target. These L-DNA biosensors directly monitor DNA hybridization, compensating for ambient environmental conditions and poor sample preparation. This report describes instrument simplifications and a comparative evaluation of both direct photothermal and plasmonic laser heating to reduce the assay time to 15 min. Instrument performance was assessed using a split sample design to compare reaction performances of 1370 and 808 nm adaptive PCR heating modalities to a standard PCR instrument. Both the novel 1370 nm direct heating and the 808 nm plasmonic method achieved target amplification similar to the traditional PCR system within 15 min. However, a major disadvantage of 808 nm heating was nanorod optical interference that reduced the fluorescence signal from PCR probes and optical cycling components. Further characterization of the 1370 nm direct heating method found comparable limits of detection of 10<sup>0</sup> copies/µL and reaction efficiencies of approximately 2 for both the 1370 nm system and the traditional PCR instrument. These results suggest that a field-deployable PCR instrument design incorporating both adaptive optical control and 1370 nm laser heating can achieve 15 min sample assay times without sacrificing analytical sensitivity.https://www.mdpi.com/2079-6374/15/4/258point of caremolecular diagnosticsrapid PCRphotothermal heatingadaptive PCRplasmonics
spellingShingle Nicholas Spurlock
Rosana Alfaro
William E. Gabella
Kunal Chugh
Megan E. Pask
Franz Baudenbacher
Frederick R. Haselton
Achievement of 15-Minute Adaptive PCR Benchmark with 1370 nm Laser Heating
Biosensors
point of care
molecular diagnostics
rapid PCR
photothermal heating
adaptive PCR
plasmonics
title Achievement of 15-Minute Adaptive PCR Benchmark with 1370 nm Laser Heating
title_full Achievement of 15-Minute Adaptive PCR Benchmark with 1370 nm Laser Heating
title_fullStr Achievement of 15-Minute Adaptive PCR Benchmark with 1370 nm Laser Heating
title_full_unstemmed Achievement of 15-Minute Adaptive PCR Benchmark with 1370 nm Laser Heating
title_short Achievement of 15-Minute Adaptive PCR Benchmark with 1370 nm Laser Heating
title_sort achievement of 15 minute adaptive pcr benchmark with 1370 nm laser heating
topic point of care
molecular diagnostics
rapid PCR
photothermal heating
adaptive PCR
plasmonics
url https://www.mdpi.com/2079-6374/15/4/258
work_keys_str_mv AT nicholasspurlock achievementof15minuteadaptivepcrbenchmarkwith1370nmlaserheating
AT rosanaalfaro achievementof15minuteadaptivepcrbenchmarkwith1370nmlaserheating
AT williamegabella achievementof15minuteadaptivepcrbenchmarkwith1370nmlaserheating
AT kunalchugh achievementof15minuteadaptivepcrbenchmarkwith1370nmlaserheating
AT meganepask achievementof15minuteadaptivepcrbenchmarkwith1370nmlaserheating
AT franzbaudenbacher achievementof15minuteadaptivepcrbenchmarkwith1370nmlaserheating
AT frederickrhaselton achievementof15minuteadaptivepcrbenchmarkwith1370nmlaserheating