Optimization of excess energy storage from an islanding micro-hydropower system as an alternative to dump loads

Abstract Energy needs in many parts of the developed world is characterized by high increase in recent years. This is due to the population growth and industrial development which require a substantial amount of energy sources. But studies have shown a different trend for many developing countries e...

Full description

Saved in:
Bibliographic Details
Main Authors: Daniel H. Ngoma, Banet Masenga, Lucy Petro
Format: Article
Language:English
Published: Springer 2025-01-01
Series:Discover Energy
Subjects:
Online Access:https://doi.org/10.1007/s43937-024-00057-1
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850115020825821184
author Daniel H. Ngoma
Banet Masenga
Lucy Petro
author_facet Daniel H. Ngoma
Banet Masenga
Lucy Petro
author_sort Daniel H. Ngoma
collection DOAJ
description Abstract Energy needs in many parts of the developed world is characterized by high increase in recent years. This is due to the population growth and industrial development which require a substantial amount of energy sources. But studies have shown a different trend for many developing countries especially in Africa where energy needs is increasing steadily and mostly in the urban areas due to the availability of national grid while in the rural and off-grid areas energy demand is supplied with the local available energy resources and technologies eg. solar energy, wind energy, hydropower or biomass energy technologies as well as hybrid energy systems. In the current research study, a water resource in a form of a small river is available in the rural and off-grid villages of the northern Tanzania. So, in this case a microhydro turbine system have been designed and developed to supply the required electrical power to the off-grid villages. The design configuration of the micro-hydro turbine systems consists of a 75 kW hydro turbine system that will supply a load demand of 1,114.38 kWh/day. But studies from the daily energy supply and demand analysis shows a power surplus of 50 kW (at night time) and power deficit of 30 kW (at evening time) from the MHP system. In this scenario the energy storage option have been considered and based on the analysis, hydrogen energy storage has been considered. This new energy storage approach has been proven to increase the energy storage capacity by eliminating 68.37% of the excess energy needed for the dump load and increasing the excess energy storage from 31.63% for the previous battery system to 100% for the hydrogen system.
format Article
id doaj-art-e844d43286fe486f97ef8a356747517d
institution OA Journals
issn 2730-7719
language English
publishDate 2025-01-01
publisher Springer
record_format Article
series Discover Energy
spelling doaj-art-e844d43286fe486f97ef8a356747517d2025-08-20T02:36:41ZengSpringerDiscover Energy2730-77192025-01-015111110.1007/s43937-024-00057-1Optimization of excess energy storage from an islanding micro-hydropower system as an alternative to dump loadsDaniel H. Ngoma0Banet Masenga1Lucy Petro2Arusha Technical College (ATC), Arusha - Tanzania and Seoul National University (SNU)Arusha Technical College (ATC)Arusha Technical College (ATC)Abstract Energy needs in many parts of the developed world is characterized by high increase in recent years. This is due to the population growth and industrial development which require a substantial amount of energy sources. But studies have shown a different trend for many developing countries especially in Africa where energy needs is increasing steadily and mostly in the urban areas due to the availability of national grid while in the rural and off-grid areas energy demand is supplied with the local available energy resources and technologies eg. solar energy, wind energy, hydropower or biomass energy technologies as well as hybrid energy systems. In the current research study, a water resource in a form of a small river is available in the rural and off-grid villages of the northern Tanzania. So, in this case a microhydro turbine system have been designed and developed to supply the required electrical power to the off-grid villages. The design configuration of the micro-hydro turbine systems consists of a 75 kW hydro turbine system that will supply a load demand of 1,114.38 kWh/day. But studies from the daily energy supply and demand analysis shows a power surplus of 50 kW (at night time) and power deficit of 30 kW (at evening time) from the MHP system. In this scenario the energy storage option have been considered and based on the analysis, hydrogen energy storage has been considered. This new energy storage approach has been proven to increase the energy storage capacity by eliminating 68.37% of the excess energy needed for the dump load and increasing the excess energy storage from 31.63% for the previous battery system to 100% for the hydrogen system.https://doi.org/10.1007/s43937-024-00057-1Microhydro turbineElectricityDump loadMbuluHhaynu RiverTanzania
spellingShingle Daniel H. Ngoma
Banet Masenga
Lucy Petro
Optimization of excess energy storage from an islanding micro-hydropower system as an alternative to dump loads
Discover Energy
Microhydro turbine
Electricity
Dump load
Mbulu
Hhaynu River
Tanzania
title Optimization of excess energy storage from an islanding micro-hydropower system as an alternative to dump loads
title_full Optimization of excess energy storage from an islanding micro-hydropower system as an alternative to dump loads
title_fullStr Optimization of excess energy storage from an islanding micro-hydropower system as an alternative to dump loads
title_full_unstemmed Optimization of excess energy storage from an islanding micro-hydropower system as an alternative to dump loads
title_short Optimization of excess energy storage from an islanding micro-hydropower system as an alternative to dump loads
title_sort optimization of excess energy storage from an islanding micro hydropower system as an alternative to dump loads
topic Microhydro turbine
Electricity
Dump load
Mbulu
Hhaynu River
Tanzania
url https://doi.org/10.1007/s43937-024-00057-1
work_keys_str_mv AT danielhngoma optimizationofexcessenergystoragefromanislandingmicrohydropowersystemasanalternativetodumploads
AT banetmasenga optimizationofexcessenergystoragefromanislandingmicrohydropowersystemasanalternativetodumploads
AT lucypetro optimizationofexcessenergystoragefromanislandingmicrohydropowersystemasanalternativetodumploads