Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal Models

Bioluminescent and fluorescent reporters are finding increased use in optical molecular imaging in small animals. In the work presented here, issues related to the sensitivity of in vivo detection are examined for standard reporters. A high-sensitivity imaging system that can detect steady-state emi...

Full description

Saved in:
Bibliographic Details
Main Authors: Tamara Troy, Dragana Jekic-McMullen, Lidia Sambucetti, Brad Rice
Format: Article
Language:English
Published: SAGE Publishing 2004-01-01
Series:Molecular Imaging
Online Access:https://doi.org/10.1162/15353500200403196
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841564502641868800
author Tamara Troy
Dragana Jekic-McMullen
Lidia Sambucetti
Brad Rice
author_facet Tamara Troy
Dragana Jekic-McMullen
Lidia Sambucetti
Brad Rice
author_sort Tamara Troy
collection DOAJ
description Bioluminescent and fluorescent reporters are finding increased use in optical molecular imaging in small animals. In the work presented here, issues related to the sensitivity of in vivo detection are examined for standard reporters. A high-sensitivity imaging system that can detect steady-state emission from both bioluminescent and fluorescent reporters is described. The instrument is absolutely calibrated so that animal images can be analyzed in physical units of radiance allowing more quantitative comparisons to be performed. Background emission from mouse tissue, called autoluminescence and autofluorescence, is measured and found to be an important limitation to detection sensitivity of reporters. Measurements of dual-labeled (bioluminescent/fluorescent) reporter systems, including PC-3M-luc/DsRed2-1 and HeLa-luc/PKH26, are shown. The results indicate that although fluorescent signals are generally brighter than bioluminescent signals, the very low autoluminescent levels usually results in superior signal to background ratios for bioluminescent imaging, particularly compared with fluorescent imaging in the green to red part of the spectrum. Fluorescence detection sensitivity improves in the far-red to near-infrared, provided the animals are fed a low-chlorophyll diet to reduce autofluorescence in the intestinal region. The use of blue-shifted excitation filters is explored as a method to subtract out tissue autofluorescence and improve the sensitivity of fluorescent imaging.
format Article
id doaj-art-e790937602494046a5c62d8d1dacd885
institution Kabale University
issn 1536-0121
language English
publishDate 2004-01-01
publisher SAGE Publishing
record_format Article
series Molecular Imaging
spelling doaj-art-e790937602494046a5c62d8d1dacd8852025-01-02T22:41:16ZengSAGE PublishingMolecular Imaging1536-01212004-01-01310.1162/1535350020040319610.1162_15353500200403196Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal ModelsTamara TroyDragana Jekic-McMullenLidia SambucettiBrad RiceBioluminescent and fluorescent reporters are finding increased use in optical molecular imaging in small animals. In the work presented here, issues related to the sensitivity of in vivo detection are examined for standard reporters. A high-sensitivity imaging system that can detect steady-state emission from both bioluminescent and fluorescent reporters is described. The instrument is absolutely calibrated so that animal images can be analyzed in physical units of radiance allowing more quantitative comparisons to be performed. Background emission from mouse tissue, called autoluminescence and autofluorescence, is measured and found to be an important limitation to detection sensitivity of reporters. Measurements of dual-labeled (bioluminescent/fluorescent) reporter systems, including PC-3M-luc/DsRed2-1 and HeLa-luc/PKH26, are shown. The results indicate that although fluorescent signals are generally brighter than bioluminescent signals, the very low autoluminescent levels usually results in superior signal to background ratios for bioluminescent imaging, particularly compared with fluorescent imaging in the green to red part of the spectrum. Fluorescence detection sensitivity improves in the far-red to near-infrared, provided the animals are fed a low-chlorophyll diet to reduce autofluorescence in the intestinal region. The use of blue-shifted excitation filters is explored as a method to subtract out tissue autofluorescence and improve the sensitivity of fluorescent imaging.https://doi.org/10.1162/15353500200403196
spellingShingle Tamara Troy
Dragana Jekic-McMullen
Lidia Sambucetti
Brad Rice
Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal Models
Molecular Imaging
title Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal Models
title_full Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal Models
title_fullStr Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal Models
title_full_unstemmed Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal Models
title_short Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal Models
title_sort quantitative comparison of the sensitivity of detection of fluorescent and bioluminescent reporters in animal models
url https://doi.org/10.1162/15353500200403196
work_keys_str_mv AT tamaratroy quantitativecomparisonofthesensitivityofdetectionoffluorescentandbioluminescentreportersinanimalmodels
AT draganajekicmcmullen quantitativecomparisonofthesensitivityofdetectionoffluorescentandbioluminescentreportersinanimalmodels
AT lidiasambucetti quantitativecomparisonofthesensitivityofdetectionoffluorescentandbioluminescentreportersinanimalmodels
AT bradrice quantitativecomparisonofthesensitivityofdetectionoffluorescentandbioluminescentreportersinanimalmodels