Design of Lightning Protection for Multi-Storey Buildings at the Malikussaleh University Rectorate Building

The Malikussaleh University Rectorate Building is a multi-storey building that is facilitated for academic and bureaucratic activities. It is necessary to safeguard against natural conditions such as lightning which may occur in the building area, including the contents of the building in the form o...

Full description

Saved in:
Bibliographic Details
Main Authors: Raihan Putri, Raihan Isra, Salahuddin Salahuddin, Muhammad Muhammad, Rafael Askarov, Ahmad Zaidi bin Abdullah
Format: Article
Language:English
Published: Lembaga Penelitian dan Pengabdian Masyarakat (LPPM), Universitas Andalas 2025-03-01
Series:Andalasian International Journal of Applied Science, Engineering, and Technology
Online Access:https://aijaset.lppm.unand.ac.id/index.php/aijaset/article/view/173
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850043510240051200
author Raihan Putri
Raihan Isra
Salahuddin Salahuddin
Muhammad Muhammad
Rafael Askarov
Ahmad Zaidi bin Abdullah
author_facet Raihan Putri
Raihan Isra
Salahuddin Salahuddin
Muhammad Muhammad
Rafael Askarov
Ahmad Zaidi bin Abdullah
author_sort Raihan Putri
collection DOAJ
description The Malikussaleh University Rectorate Building is a multi-storey building that is facilitated for academic and bureaucratic activities. It is necessary to safeguard against natural conditions such as lightning which may occur in the building area, including the contents of the building in the form of many electronic equipment connected to electricity such as computers, television, radio, CCTV, telephone and various other electronic equipment. Based on data received from the Meteorology, Climatology and Geophysics Agency (BMKG), 393 lightning strikes occurred in North Aceh, especially the Reuleut area, from February to May 2023. Building protection can be determined based on calculations calculated using several subclassifications of the General Installation Regulations Lightning Distribution (PUIPP). based on the level of need according to the PUIPP standard with a value of R=16, NFPA with a value of R=22, and IEC 1024-1-1 value of E= 95% with level II protection. The design of the lightning rod follows the PUIPP Standard by using a type, namely an air termination system with the brand "Kurn R-85" which has a protection radius of 85 m2. To apply an electrostatic lightning rod, simply install one lightning rod on top of the building at a height of 25 m from the ground, then connect it to ground using a 50 mm2 BC cable
format Article
id doaj-art-e78a2d50da4948cba7e1f58b81a11deb
institution DOAJ
issn 2797-0442
language English
publishDate 2025-03-01
publisher Lembaga Penelitian dan Pengabdian Masyarakat (LPPM), Universitas Andalas
record_format Article
series Andalasian International Journal of Applied Science, Engineering, and Technology
spelling doaj-art-e78a2d50da4948cba7e1f58b81a11deb2025-08-20T02:55:13ZengLembaga Penelitian dan Pengabdian Masyarakat (LPPM), Universitas AndalasAndalasian International Journal of Applied Science, Engineering, and Technology2797-04422025-03-0151142610.25077/aijaset.v5i1.173173Design of Lightning Protection for Multi-Storey Buildings at the Malikussaleh University Rectorate BuildingRaihan Putri0Raihan Isra1Salahuddin Salahuddin2Muhammad Muhammad3Rafael Askarov4Ahmad Zaidi bin Abdullah5Universitas Malikussaleh, IndonesiaUniversitas Malikussaleh, IndonesiaUniversitas Malikussaleh, IndonesiaUniversitas Malikussaleh, IndonesiaKazan State Power Engineering University, RusiaUniversiti Malaysia Perlis, MalaysiaThe Malikussaleh University Rectorate Building is a multi-storey building that is facilitated for academic and bureaucratic activities. It is necessary to safeguard against natural conditions such as lightning which may occur in the building area, including the contents of the building in the form of many electronic equipment connected to electricity such as computers, television, radio, CCTV, telephone and various other electronic equipment. Based on data received from the Meteorology, Climatology and Geophysics Agency (BMKG), 393 lightning strikes occurred in North Aceh, especially the Reuleut area, from February to May 2023. Building protection can be determined based on calculations calculated using several subclassifications of the General Installation Regulations Lightning Distribution (PUIPP). based on the level of need according to the PUIPP standard with a value of R=16, NFPA with a value of R=22, and IEC 1024-1-1 value of E= 95% with level II protection. The design of the lightning rod follows the PUIPP Standard by using a type, namely an air termination system with the brand "Kurn R-85" which has a protection radius of 85 m2. To apply an electrostatic lightning rod, simply install one lightning rod on top of the building at a height of 25 m from the ground, then connect it to ground using a 50 mm2 BC cablehttps://aijaset.lppm.unand.ac.id/index.php/aijaset/article/view/173
spellingShingle Raihan Putri
Raihan Isra
Salahuddin Salahuddin
Muhammad Muhammad
Rafael Askarov
Ahmad Zaidi bin Abdullah
Design of Lightning Protection for Multi-Storey Buildings at the Malikussaleh University Rectorate Building
Andalasian International Journal of Applied Science, Engineering, and Technology
title Design of Lightning Protection for Multi-Storey Buildings at the Malikussaleh University Rectorate Building
title_full Design of Lightning Protection for Multi-Storey Buildings at the Malikussaleh University Rectorate Building
title_fullStr Design of Lightning Protection for Multi-Storey Buildings at the Malikussaleh University Rectorate Building
title_full_unstemmed Design of Lightning Protection for Multi-Storey Buildings at the Malikussaleh University Rectorate Building
title_short Design of Lightning Protection for Multi-Storey Buildings at the Malikussaleh University Rectorate Building
title_sort design of lightning protection for multi storey buildings at the malikussaleh university rectorate building
url https://aijaset.lppm.unand.ac.id/index.php/aijaset/article/view/173
work_keys_str_mv AT raihanputri designoflightningprotectionformultistoreybuildingsatthemalikussalehuniversityrectoratebuilding
AT raihanisra designoflightningprotectionformultistoreybuildingsatthemalikussalehuniversityrectoratebuilding
AT salahuddinsalahuddin designoflightningprotectionformultistoreybuildingsatthemalikussalehuniversityrectoratebuilding
AT muhammadmuhammad designoflightningprotectionformultistoreybuildingsatthemalikussalehuniversityrectoratebuilding
AT rafaelaskarov designoflightningprotectionformultistoreybuildingsatthemalikussalehuniversityrectoratebuilding
AT ahmadzaidibinabdullah designoflightningprotectionformultistoreybuildingsatthemalikussalehuniversityrectoratebuilding