Wall Shading Losses of Photovoltaic Systems

The deployment of photovoltaic (PV) systems on rooftops in urban environments may encounter shading on the PV collectors from surrounding walls, acting adversely on the generated electricity of the PV systems. Most studies on the shading of PV systems do not deal analytically with the shading losses...

Full description

Saved in:
Bibliographic Details
Main Authors: Joseph Appelbaum, Assaf Peled, Avi Aronescu
Format: Article
Language:English
Published: MDPI AG 2024-10-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/17/20/5089
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The deployment of photovoltaic (PV) systems on rooftops in urban environments may encounter shading on the PV collectors from surrounding walls, acting adversely on the generated electricity of the PV systems. Most studies on the shading of PV systems do not deal analytically with the shading losses of PV collectors affected by walls, fences, and obscuring objects. The present article mathematically formulates shadow expressions for wall and inter-row shading on PV collectors and calculates the percentage of annual shading losses affected by wall heights and azimuth angles, the distances of walls to collectors, and the length and azimuth angles of collectors. This study indicates that the shading losses increase for shorter distances from the collector to the walls and for higher walls. Shading losses may reach 7 percent for wall heights of 4 m and at a distance of 2 m from the collectors to a wall. The results indicate that wall shading dominates inter-row shading.