3SqAir Project: A Living Lab Towards Sustainable Smart Strategy for Indoor Climate Quality Assurance in Classrooms

The indoor climate quality in classrooms at the University of Coimbra, Portugal, was investigated as part of the 3SqAir project, supported by the Interreg SUDOE program. This research focused on two equipped classrooms with different ventilation systems: natural and mechanical ventilation. Both clas...

Full description

Saved in:
Bibliographic Details
Main Authors: James Ogundiran, Jean-Paul Kapuya Bulaba Nyembwe, John Omomoluwa Ogundiran, Ruben Alexandre de Souto Santos, Luísa Dias Pereira, Manuel Gameiro da Silva
Format: Article
Language:English
Published: MDPI AG 2025-05-01
Series:Atmosphere
Subjects:
Online Access:https://www.mdpi.com/2073-4433/16/5/584
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849711596959432704
author James Ogundiran
Jean-Paul Kapuya Bulaba Nyembwe
John Omomoluwa Ogundiran
Ruben Alexandre de Souto Santos
Luísa Dias Pereira
Manuel Gameiro da Silva
author_facet James Ogundiran
Jean-Paul Kapuya Bulaba Nyembwe
John Omomoluwa Ogundiran
Ruben Alexandre de Souto Santos
Luísa Dias Pereira
Manuel Gameiro da Silva
author_sort James Ogundiran
collection DOAJ
description The indoor climate quality in classrooms at the University of Coimbra, Portugal, was investigated as part of the 3SqAir project, supported by the Interreg SUDOE program. This research focused on two equipped classrooms with different ventilation systems: natural and mechanical ventilation. Both classrooms were continuously monitored for IEQ parameters: thermal comfort, indoor air quality, noise, and lighting during heating and cooling seasons. Air temperature, relative humidity, CO<sub>2</sub> concentration, particulate matter, nitrogen dioxide, volatile organic compounds, formaldehyde, sound pressure level, and illuminance were measured. Outdoor weather conditions were also recorded. The primary focus was on air temperature, CO<sub>2</sub> concentrations, and relative humidity, while air change rates (ACH) were estimated using the Tracer Gas Method. The results showed inadequate thermal conditions in both classrooms, particularly during the heating season. Most weekly mean CO<sub>2</sub> concentrations were within acceptable limits, while ACH were below standard recommendations in four CO<sub>2</sub> decay phases. Simulations of CO<sub>2</sub> decay revealed further air quality gaps in each room. Corrective measures within the 3SqAir project framework were suggested for approval and implementation while monitoring continues. This work represents the first phase in an evolving study towards developing sustainable strategies for improving indoor air quality in classrooms.
format Article
id doaj-art-e776d63dda0a4d4aa9713625dabdc2e2
institution DOAJ
issn 2073-4433
language English
publishDate 2025-05-01
publisher MDPI AG
record_format Article
series Atmosphere
spelling doaj-art-e776d63dda0a4d4aa9713625dabdc2e22025-08-20T03:14:35ZengMDPI AGAtmosphere2073-44332025-05-0116558410.3390/atmos160505843SqAir Project: A Living Lab Towards Sustainable Smart Strategy for Indoor Climate Quality Assurance in ClassroomsJames Ogundiran0Jean-Paul Kapuya Bulaba Nyembwe1John Omomoluwa Ogundiran2Ruben Alexandre de Souto Santos3Luísa Dias Pereira4Manuel Gameiro da Silva5Department of Mechanical Engineering Pólo II, University of Coimbra, ADAI-LAETA, Rua Luís Reis Santos, 3030-788 Coimbra, PortugalDepartment of Mechanical Engineering Pólo II, University of Coimbra, ADAI-LAETA, Rua Luís Reis Santos, 3030-788 Coimbra, PortugalDepartment of Mechanical Engineering Pólo II, University of Coimbra, ADAI-LAETA, Rua Luís Reis Santos, 3030-788 Coimbra, PortugalDepartment of Mechanical Engineering Pólo II, University of Coimbra, ADAI-LAETA, Rua Luís Reis Santos, 3030-788 Coimbra, PortugalDepartment of Mechanical Engineering Pólo II, University of Coimbra, ADAI-LAETA, Rua Luís Reis Santos, 3030-788 Coimbra, PortugalDepartment of Mechanical Engineering Pólo II, University of Coimbra, ADAI-LAETA, Rua Luís Reis Santos, 3030-788 Coimbra, PortugalThe indoor climate quality in classrooms at the University of Coimbra, Portugal, was investigated as part of the 3SqAir project, supported by the Interreg SUDOE program. This research focused on two equipped classrooms with different ventilation systems: natural and mechanical ventilation. Both classrooms were continuously monitored for IEQ parameters: thermal comfort, indoor air quality, noise, and lighting during heating and cooling seasons. Air temperature, relative humidity, CO<sub>2</sub> concentration, particulate matter, nitrogen dioxide, volatile organic compounds, formaldehyde, sound pressure level, and illuminance were measured. Outdoor weather conditions were also recorded. The primary focus was on air temperature, CO<sub>2</sub> concentrations, and relative humidity, while air change rates (ACH) were estimated using the Tracer Gas Method. The results showed inadequate thermal conditions in both classrooms, particularly during the heating season. Most weekly mean CO<sub>2</sub> concentrations were within acceptable limits, while ACH were below standard recommendations in four CO<sub>2</sub> decay phases. Simulations of CO<sub>2</sub> decay revealed further air quality gaps in each room. Corrective measures within the 3SqAir project framework were suggested for approval and implementation while monitoring continues. This work represents the first phase in an evolving study towards developing sustainable strategies for improving indoor air quality in classrooms.https://www.mdpi.com/2073-4433/16/5/584indoor air qualitythermal comfortclassrooms
spellingShingle James Ogundiran
Jean-Paul Kapuya Bulaba Nyembwe
John Omomoluwa Ogundiran
Ruben Alexandre de Souto Santos
Luísa Dias Pereira
Manuel Gameiro da Silva
3SqAir Project: A Living Lab Towards Sustainable Smart Strategy for Indoor Climate Quality Assurance in Classrooms
Atmosphere
indoor air quality
thermal comfort
classrooms
title 3SqAir Project: A Living Lab Towards Sustainable Smart Strategy for Indoor Climate Quality Assurance in Classrooms
title_full 3SqAir Project: A Living Lab Towards Sustainable Smart Strategy for Indoor Climate Quality Assurance in Classrooms
title_fullStr 3SqAir Project: A Living Lab Towards Sustainable Smart Strategy for Indoor Climate Quality Assurance in Classrooms
title_full_unstemmed 3SqAir Project: A Living Lab Towards Sustainable Smart Strategy for Indoor Climate Quality Assurance in Classrooms
title_short 3SqAir Project: A Living Lab Towards Sustainable Smart Strategy for Indoor Climate Quality Assurance in Classrooms
title_sort 3sqair project a living lab towards sustainable smart strategy for indoor climate quality assurance in classrooms
topic indoor air quality
thermal comfort
classrooms
url https://www.mdpi.com/2073-4433/16/5/584
work_keys_str_mv AT jamesogundiran 3sqairprojectalivinglabtowardssustainablesmartstrategyforindoorclimatequalityassuranceinclassrooms
AT jeanpaulkapuyabulabanyembwe 3sqairprojectalivinglabtowardssustainablesmartstrategyforindoorclimatequalityassuranceinclassrooms
AT johnomomoluwaogundiran 3sqairprojectalivinglabtowardssustainablesmartstrategyforindoorclimatequalityassuranceinclassrooms
AT rubenalexandredesoutosantos 3sqairprojectalivinglabtowardssustainablesmartstrategyforindoorclimatequalityassuranceinclassrooms
AT luisadiaspereira 3sqairprojectalivinglabtowardssustainablesmartstrategyforindoorclimatequalityassuranceinclassrooms
AT manuelgameirodasilva 3sqairprojectalivinglabtowardssustainablesmartstrategyforindoorclimatequalityassuranceinclassrooms