About Safe Loads of Cables with Cross-Linked Polyethylene Insulation

Permissible long currents of cables with voltage 6-lOkV and cross-linked polyethylene insulation are considered in the paper. Smoothing functions have been obtained to estimate permissible long densities of the current in three- and single-core cables at various types of a lining and an arrangement....

Full description

Saved in:
Bibliographic Details
Main Authors: V. N. Radkevich, R. V. Romanov
Format: Article
Language:Russian
Published: Belarusian National Technical University 2006-06-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Online Access:https://energy.bntu.by/jour/article/view/801
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849400784313122816
author V. N. Radkevich
R. V. Romanov
author_facet V. N. Radkevich
R. V. Romanov
author_sort V. N. Radkevich
collection DOAJ
description Permissible long currents of cables with voltage 6-lOkV and cross-linked polyethylene insulation are considered in the paper. Smoothing functions have been obtained to estimate permissible long densities of the current in three- and single-core cables at various types of a lining and an arrangement. It is shown that in the field of large section conductors permissible values of current densities in heating can be less than economic ones.
format Article
id doaj-art-e6e3a29b0f1843938b0aee00f5588ce6
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2006-06-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-e6e3a29b0f1843938b0aee00f5588ce62025-08-20T03:37:54ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412006-06-01036166794About Safe Loads of Cables with Cross-Linked Polyethylene InsulationV. N. RadkevichR. V. RomanovPermissible long currents of cables with voltage 6-lOkV and cross-linked polyethylene insulation are considered in the paper. Smoothing functions have been obtained to estimate permissible long densities of the current in three- and single-core cables at various types of a lining and an arrangement. It is shown that in the field of large section conductors permissible values of current densities in heating can be less than economic ones.https://energy.bntu.by/jour/article/view/801
spellingShingle V. N. Radkevich
R. V. Romanov
About Safe Loads of Cables with Cross-Linked Polyethylene Insulation
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
title About Safe Loads of Cables with Cross-Linked Polyethylene Insulation
title_full About Safe Loads of Cables with Cross-Linked Polyethylene Insulation
title_fullStr About Safe Loads of Cables with Cross-Linked Polyethylene Insulation
title_full_unstemmed About Safe Loads of Cables with Cross-Linked Polyethylene Insulation
title_short About Safe Loads of Cables with Cross-Linked Polyethylene Insulation
title_sort about safe loads of cables with cross linked polyethylene insulation
url https://energy.bntu.by/jour/article/view/801
work_keys_str_mv AT vnradkevich aboutsafeloadsofcableswithcrosslinkedpolyethyleneinsulation
AT rvromanov aboutsafeloadsofcableswithcrosslinkedpolyethyleneinsulation