Correlation of Corneoscleral Membrane Biomechanical Properties and Eye Morphometric Parameters in Patients with Primary Open-Angle Glaucoma

Purpose: to study a correlation between morphometric parameters of the eye and tonometry data, taking into account viscoelastic properties of the cornea in patients with primary open-angle glaucoma (POAG), as well as in practically healthy individuals using different methods of tonometry. Patients a...

Full description

Saved in:
Bibliographic Details
Main Authors: B. M. Aznabaev, A. Sh. Zagidullina, I. A. Lakman, R. R. Islamova, R. R. Sattarova
Format: Article
Language:Russian
Published: Ophthalmology Publishing Group 2019-10-01
Series:Oftalʹmologiâ
Subjects:
Online Access:https://www.ophthalmojournal.com/opht/article/view/1011
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849240837915934720
author B. M. Aznabaev
A. Sh. Zagidullina
I. A. Lakman
R. R. Islamova
R. R. Sattarova
author_facet B. M. Aznabaev
A. Sh. Zagidullina
I. A. Lakman
R. R. Islamova
R. R. Sattarova
author_sort B. M. Aznabaev
collection DOAJ
description Purpose: to study a correlation between morphometric parameters of the eye and tonometry data, taking into account viscoelastic properties of the cornea in patients with primary open-angle glaucoma (POAG), as well as in practically healthy individuals using different methods of tonometry. Patients and Methods. Correlations between morphometric parameters of the eye and tonometry data were studied in view of viscoelastic properties of the cornea in 51 patients with POAG who were observed at the “Optimed” Laser Vision Recovery Center in Ufa (99 eyes) and in 31 practically healthy individuals (62 eyes). Various methods of tonometry were used: tonometry according to Maklakov, contactless tonometry, tonometry with the Ocular Response Analyzer (ORA, Reichert Inc., USA), as well as ultrasound echobiometry, pachymetry. Results. The CH and CRF parameters reflecting the biomechanical properties of the corneoscleral membrane of the eye were close in value to each other with a high degree of positive correlation in the control group (ρ = 0.783, p < 0.001), with an average correlation in the group with POAG (ρ = 0.545, p < 0.001). In eyes with POAG, a negative CH correlation of average degree with corneal-compensated IOP (ρ = -0.572, p < 0.001), a negative CRF correlation of moderate degree with IOP by the Maklakov method (ρ = -0.346, p < 0.001) and corneal-compensated IOP with dynamic bi-directional applanation tonometry (ρ = -0.327, p = 0.001), low correlation with IOP using contactless tonometry (ρ = 0.243, p < 0.015) were observed. In the group of patients with POAG, a positive average correlation was found between the central thickness of the cornea and CRF (ρ = 0.398, p < 0.001), and CH (ρ = 0.368, p < 0.001), low correlation with IOP using contactless tonometry (ρ = 0.266, p = 0.008). Conclusion. Correlations of biomechanical properties of the corneoscleral membrane and morphometric parameters of the eye in patients with POAG were revealed using different methods of tonometry. In the group of patients with POAG and in the control group, positive correlations of the central thickness of the cornea with the IOP level in tonometry were determined by the contactless method, as well as with the main ORA parameters reflecting the visco-elastic properties of the fibrous membrane of the eye — the corneal resistance factor, corneal hysteresis.
format Article
id doaj-art-e6db78f0b0dd4371ae3ced16f5d83ac9
institution Kabale University
issn 1816-5095
2500-0845
language Russian
publishDate 2019-10-01
publisher Ophthalmology Publishing Group
record_format Article
series Oftalʹmologiâ
spelling doaj-art-e6db78f0b0dd4371ae3ced16f5d83ac92025-08-20T04:00:25ZrusOphthalmology Publishing GroupOftalʹmologiâ1816-50952500-08452019-10-0116333534310.18008/1816-5095-2019-3-335-343559Correlation of Corneoscleral Membrane Biomechanical Properties and Eye Morphometric Parameters in Patients with Primary Open-Angle GlaucomaB. M. Aznabaev0A. Sh. Zagidullina1I. A. Lakman2R. R. Islamova3R. R. Sattarova4Bashkir Federal State Medical UniversityBashkir Federal State Medical UniversityUfa Federal State Aviation Technical UniversityUfa Federal State Aviation Technical UniversityZAO “Optimedservis”Purpose: to study a correlation between morphometric parameters of the eye and tonometry data, taking into account viscoelastic properties of the cornea in patients with primary open-angle glaucoma (POAG), as well as in practically healthy individuals using different methods of tonometry. Patients and Methods. Correlations between morphometric parameters of the eye and tonometry data were studied in view of viscoelastic properties of the cornea in 51 patients with POAG who were observed at the “Optimed” Laser Vision Recovery Center in Ufa (99 eyes) and in 31 practically healthy individuals (62 eyes). Various methods of tonometry were used: tonometry according to Maklakov, contactless tonometry, tonometry with the Ocular Response Analyzer (ORA, Reichert Inc., USA), as well as ultrasound echobiometry, pachymetry. Results. The CH and CRF parameters reflecting the biomechanical properties of the corneoscleral membrane of the eye were close in value to each other with a high degree of positive correlation in the control group (ρ = 0.783, p < 0.001), with an average correlation in the group with POAG (ρ = 0.545, p < 0.001). In eyes with POAG, a negative CH correlation of average degree with corneal-compensated IOP (ρ = -0.572, p < 0.001), a negative CRF correlation of moderate degree with IOP by the Maklakov method (ρ = -0.346, p < 0.001) and corneal-compensated IOP with dynamic bi-directional applanation tonometry (ρ = -0.327, p = 0.001), low correlation with IOP using contactless tonometry (ρ = 0.243, p < 0.015) were observed. In the group of patients with POAG, a positive average correlation was found between the central thickness of the cornea and CRF (ρ = 0.398, p < 0.001), and CH (ρ = 0.368, p < 0.001), low correlation with IOP using contactless tonometry (ρ = 0.266, p = 0.008). Conclusion. Correlations of biomechanical properties of the corneoscleral membrane and morphometric parameters of the eye in patients with POAG were revealed using different methods of tonometry. In the group of patients with POAG and in the control group, positive correlations of the central thickness of the cornea with the IOP level in tonometry were determined by the contactless method, as well as with the main ORA parameters reflecting the visco-elastic properties of the fibrous membrane of the eye — the corneal resistance factor, corneal hysteresis.https://www.ophthalmojournal.com/opht/article/view/1011primary open-angle glaucomamaklakov tonometrycontactless tonometrydynamic bi-directional applanation tonometryocular response analyzercentral corneal thickness
spellingShingle B. M. Aznabaev
A. Sh. Zagidullina
I. A. Lakman
R. R. Islamova
R. R. Sattarova
Correlation of Corneoscleral Membrane Biomechanical Properties and Eye Morphometric Parameters in Patients with Primary Open-Angle Glaucoma
Oftalʹmologiâ
primary open-angle glaucoma
maklakov tonometry
contactless tonometry
dynamic bi-directional applanation tonometry
ocular response analyzer
central corneal thickness
title Correlation of Corneoscleral Membrane Biomechanical Properties and Eye Morphometric Parameters in Patients with Primary Open-Angle Glaucoma
title_full Correlation of Corneoscleral Membrane Biomechanical Properties and Eye Morphometric Parameters in Patients with Primary Open-Angle Glaucoma
title_fullStr Correlation of Corneoscleral Membrane Biomechanical Properties and Eye Morphometric Parameters in Patients with Primary Open-Angle Glaucoma
title_full_unstemmed Correlation of Corneoscleral Membrane Biomechanical Properties and Eye Morphometric Parameters in Patients with Primary Open-Angle Glaucoma
title_short Correlation of Corneoscleral Membrane Biomechanical Properties and Eye Morphometric Parameters in Patients with Primary Open-Angle Glaucoma
title_sort correlation of corneoscleral membrane biomechanical properties and eye morphometric parameters in patients with primary open angle glaucoma
topic primary open-angle glaucoma
maklakov tonometry
contactless tonometry
dynamic bi-directional applanation tonometry
ocular response analyzer
central corneal thickness
url https://www.ophthalmojournal.com/opht/article/view/1011
work_keys_str_mv AT bmaznabaev correlationofcorneoscleralmembranebiomechanicalpropertiesandeyemorphometricparametersinpatientswithprimaryopenangleglaucoma
AT ashzagidullina correlationofcorneoscleralmembranebiomechanicalpropertiesandeyemorphometricparametersinpatientswithprimaryopenangleglaucoma
AT ialakman correlationofcorneoscleralmembranebiomechanicalpropertiesandeyemorphometricparametersinpatientswithprimaryopenangleglaucoma
AT rrislamova correlationofcorneoscleralmembranebiomechanicalpropertiesandeyemorphometricparametersinpatientswithprimaryopenangleglaucoma
AT rrsattarova correlationofcorneoscleralmembranebiomechanicalpropertiesandeyemorphometricparametersinpatientswithprimaryopenangleglaucoma