Experimental Study on Characteristics of Energy Storage Defrosting and Conventional Defrosting for Cascade Air Source Heat Pump

Based on the frosting and defrosting problems of cascade air source heat pumps (CASHPs) during heating operation in the cold area in winter, a novel thermal energy storage CASHP defrosting system with a thermal accumulator is proposed. The defrosting performances of thermal energy storage defrosting...

Full description

Saved in:
Bibliographic Details
Main Authors: Qu Minglu, Li Tianrui, Fan Yanan, Wang Tan
Format: Article
Language:zho
Published: Journal of Refrigeration Magazines Agency Co., Ltd. 2017-01-01
Series:Zhileng xuebao
Subjects:
Online Access:http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2017.01.034
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850235282219073536
author Qu Minglu
Li Tianrui
Fan Yanan
Wang Tan
author_facet Qu Minglu
Li Tianrui
Fan Yanan
Wang Tan
author_sort Qu Minglu
collection DOAJ
description Based on the frosting and defrosting problems of cascade air source heat pumps (CASHPs) during heating operation in the cold area in winter, a novel thermal energy storage CASHP defrosting system with a thermal accumulator is proposed. The defrosting performances of thermal energy storage defrosting mode with intermittent heating and continuous heating were experimentally studied, and then the experimental results were compared with common used hot-gas bypass defrosting mode. It was found that in energy storage defrosting mode, the defrosting duration time and the energy consumption were reduced by 71.4%~77.6% and 65.1%~85.2% respectively compared with hot-gas bypass defrosting mode, and the system defrosting operation was more stable and reliable.
format Article
id doaj-art-e6d855b932c645978b14a23253b07f73
institution OA Journals
issn 0253-4339
language zho
publishDate 2017-01-01
publisher Journal of Refrigeration Magazines Agency Co., Ltd.
record_format Article
series Zhileng xuebao
spelling doaj-art-e6d855b932c645978b14a23253b07f732025-08-20T02:02:19ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392017-01-013866512075Experimental Study on Characteristics of Energy Storage Defrosting and Conventional Defrosting for Cascade Air Source Heat PumpQu MingluLi TianruiFan YananWang TanBased on the frosting and defrosting problems of cascade air source heat pumps (CASHPs) during heating operation in the cold area in winter, a novel thermal energy storage CASHP defrosting system with a thermal accumulator is proposed. The defrosting performances of thermal energy storage defrosting mode with intermittent heating and continuous heating were experimentally studied, and then the experimental results were compared with common used hot-gas bypass defrosting mode. It was found that in energy storage defrosting mode, the defrosting duration time and the energy consumption were reduced by 71.4%~77.6% and 65.1%~85.2% respectively compared with hot-gas bypass defrosting mode, and the system defrosting operation was more stable and reliable.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2017.01.034air source heat pumpcascade cycledefrostingthermal accumulator
spellingShingle Qu Minglu
Li Tianrui
Fan Yanan
Wang Tan
Experimental Study on Characteristics of Energy Storage Defrosting and Conventional Defrosting for Cascade Air Source Heat Pump
Zhileng xuebao
air source heat pump
cascade cycle
defrosting
thermal accumulator
title Experimental Study on Characteristics of Energy Storage Defrosting and Conventional Defrosting for Cascade Air Source Heat Pump
title_full Experimental Study on Characteristics of Energy Storage Defrosting and Conventional Defrosting for Cascade Air Source Heat Pump
title_fullStr Experimental Study on Characteristics of Energy Storage Defrosting and Conventional Defrosting for Cascade Air Source Heat Pump
title_full_unstemmed Experimental Study on Characteristics of Energy Storage Defrosting and Conventional Defrosting for Cascade Air Source Heat Pump
title_short Experimental Study on Characteristics of Energy Storage Defrosting and Conventional Defrosting for Cascade Air Source Heat Pump
title_sort experimental study on characteristics of energy storage defrosting and conventional defrosting for cascade air source heat pump
topic air source heat pump
cascade cycle
defrosting
thermal accumulator
url http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2017.01.034
work_keys_str_mv AT quminglu experimentalstudyoncharacteristicsofenergystoragedefrostingandconventionaldefrostingforcascadeairsourceheatpump
AT litianrui experimentalstudyoncharacteristicsofenergystoragedefrostingandconventionaldefrostingforcascadeairsourceheatpump
AT fanyanan experimentalstudyoncharacteristicsofenergystoragedefrostingandconventionaldefrostingforcascadeairsourceheatpump
AT wangtan experimentalstudyoncharacteristicsofenergystoragedefrostingandconventionaldefrostingforcascadeairsourceheatpump