Structural Deterioration and Failure of the Laminated Wooden Roof of a Covered Swimming Pool

A swimming pool in Corrales de Buelna (Cantabria) was demolished in March 2017 due to the loss of mechanical performance of the laminated timber structure. The relevant deterioration was caused by rotting of the wood and corrosion of the metal connecting elements. The structure featured a barrel vau...

Full description

Saved in:
Bibliographic Details
Main Authors: Javier Pinilla-Melo, Nelson Flores-Medina, Luis Javier Sánchez-Aparicio, Jose Ramón Aira-Zunzunegui
Format: Article
Language:English
Published: MDPI AG 2024-11-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/14/12/3794
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850050165642100736
author Javier Pinilla-Melo
Nelson Flores-Medina
Luis Javier Sánchez-Aparicio
Jose Ramón Aira-Zunzunegui
author_facet Javier Pinilla-Melo
Nelson Flores-Medina
Luis Javier Sánchez-Aparicio
Jose Ramón Aira-Zunzunegui
author_sort Javier Pinilla-Melo
collection DOAJ
description A swimming pool in Corrales de Buelna (Cantabria) was demolished in March 2017 due to the loss of mechanical performance of the laminated timber structure. The relevant deterioration was caused by rotting of the wood and corrosion of the metal connecting elements. The structure featured a barrel vault with five large tri-articulated arches enclosed on the sides by inclined facades formed by toral rafters and purlins. The corresponding diagnostic process involved data collection and structural assessments to verify the structure’s bearing capacity and serviceability. Data collection was carried out in December 2015 and consisted of a thermal camera inspection to determine the points of moisture accumulation and sampling openings, conduct environmental and wood hygrothermal measurements, and measure cross-sectional losses and deformations of the structural elements. Verification of the load-bearing capacity was carried out using matrix calculation structure software for both the original and deteriorated structure. The diagnosis indicated that the damage was caused by leaks in the joints of the aluminum composite roof panels and by the insufficient load-bearing capacity of the structure. The severity of the damage compromised the mechanical strength and stability of the building, leading to a recommendation that the use of the facilities be immediately discontinued. The degree of deterioration left the structure unrecoverable, making it very difficult to apply reinforcement measures. These factors led to the structure’s demolition to prevent its collapse.
format Article
id doaj-art-e6c55c9325ef457090a20465f17125eb
institution DOAJ
issn 2075-5309
language English
publishDate 2024-11-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj-art-e6c55c9325ef457090a20465f17125eb2025-08-20T02:53:33ZengMDPI AGBuildings2075-53092024-11-011412379410.3390/buildings14123794Structural Deterioration and Failure of the Laminated Wooden Roof of a Covered Swimming PoolJavier Pinilla-Melo0Nelson Flores-Medina1Luis Javier Sánchez-Aparicio2Jose Ramón Aira-Zunzunegui3Department of Construction and Technology in Architecture (DCTA), Escuela Técnica Superior de Arquitectura de Madrid (ETSAM), Universidad Politécnica de Madrid, Av. Juan de Herrera, 4, 28040 Madrid, SpainDepartament of Architectonic Construction, Escuela de Arquitectura, Universidad de Las Palmas de Gran Canaria, Campus Universitario de Tafira, 35017 Las Palmas, SpainDepartment of Construction and Technology in Architecture (DCTA), Escuela Técnica Superior de Arquitectura de Madrid (ETSAM), Universidad Politécnica de Madrid, Av. Juan de Herrera, 4, 28040 Madrid, SpainDepartment of Construction and Technology in Architecture (DCTA), Escuela Técnica Superior de Arquitectura de Madrid (ETSAM), Universidad Politécnica de Madrid, Av. Juan de Herrera, 4, 28040 Madrid, SpainA swimming pool in Corrales de Buelna (Cantabria) was demolished in March 2017 due to the loss of mechanical performance of the laminated timber structure. The relevant deterioration was caused by rotting of the wood and corrosion of the metal connecting elements. The structure featured a barrel vault with five large tri-articulated arches enclosed on the sides by inclined facades formed by toral rafters and purlins. The corresponding diagnostic process involved data collection and structural assessments to verify the structure’s bearing capacity and serviceability. Data collection was carried out in December 2015 and consisted of a thermal camera inspection to determine the points of moisture accumulation and sampling openings, conduct environmental and wood hygrothermal measurements, and measure cross-sectional losses and deformations of the structural elements. Verification of the load-bearing capacity was carried out using matrix calculation structure software for both the original and deteriorated structure. The diagnosis indicated that the damage was caused by leaks in the joints of the aluminum composite roof panels and by the insufficient load-bearing capacity of the structure. The severity of the damage compromised the mechanical strength and stability of the building, leading to a recommendation that the use of the facilities be immediately discontinued. The degree of deterioration left the structure unrecoverable, making it very difficult to apply reinforcement measures. These factors led to the structure’s demolition to prevent its collapse.https://www.mdpi.com/2075-5309/14/12/3794structural failuredamage diagnosisnon-destructive testingglulamwet rotcorrosion
spellingShingle Javier Pinilla-Melo
Nelson Flores-Medina
Luis Javier Sánchez-Aparicio
Jose Ramón Aira-Zunzunegui
Structural Deterioration and Failure of the Laminated Wooden Roof of a Covered Swimming Pool
Buildings
structural failure
damage diagnosis
non-destructive testing
glulam
wet rot
corrosion
title Structural Deterioration and Failure of the Laminated Wooden Roof of a Covered Swimming Pool
title_full Structural Deterioration and Failure of the Laminated Wooden Roof of a Covered Swimming Pool
title_fullStr Structural Deterioration and Failure of the Laminated Wooden Roof of a Covered Swimming Pool
title_full_unstemmed Structural Deterioration and Failure of the Laminated Wooden Roof of a Covered Swimming Pool
title_short Structural Deterioration and Failure of the Laminated Wooden Roof of a Covered Swimming Pool
title_sort structural deterioration and failure of the laminated wooden roof of a covered swimming pool
topic structural failure
damage diagnosis
non-destructive testing
glulam
wet rot
corrosion
url https://www.mdpi.com/2075-5309/14/12/3794
work_keys_str_mv AT javierpinillamelo structuraldeteriorationandfailureofthelaminatedwoodenroofofacoveredswimmingpool
AT nelsonfloresmedina structuraldeteriorationandfailureofthelaminatedwoodenroofofacoveredswimmingpool
AT luisjaviersanchezaparicio structuraldeteriorationandfailureofthelaminatedwoodenroofofacoveredswimmingpool
AT joseramonairazunzunegui structuraldeteriorationandfailureofthelaminatedwoodenroofofacoveredswimmingpool