A Simple and Reliable Setup for Monitoring Corrosion Rate of Steel Rebars in Concrete
The accuracy in the measurement of the rate of corrosion of steel in concrete depends on many factors. The high resistivity of concrete makes the polarization data erroneous due to the Ohmic drop. The other source of error is the use of an arbitrarily assumed value of the Stern-Geary constant for ca...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2014-01-01
|
Series: | The Scientific World Journal |
Online Access: | http://dx.doi.org/10.1155/2014/525678 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832551641851625472 |
---|---|
author | Shamsad Ahmad Mohammed Abdul Azeem Jibran Abul Kalam Azad Mohammed Maslehuddin |
author_facet | Shamsad Ahmad Mohammed Abdul Azeem Jibran Abul Kalam Azad Mohammed Maslehuddin |
author_sort | Shamsad Ahmad |
collection | DOAJ |
description | The accuracy in the measurement of the rate of corrosion of steel in concrete depends on many factors. The high resistivity of concrete makes the polarization data erroneous due to the Ohmic drop. The other source of error is the use of an arbitrarily assumed value of the Stern-Geary constant for calculating corrosion current density. This paper presents the outcomes of a research work conducted to develop a reliable and low-cost experimental setup and a simple calculation procedure that can be utilised to calculate the corrosion current density considering the Ohmic drop compensation and the actual value of the Stern-Geary constants calculated using the polarization data. The measurements conducted on specimens corroded to different levels indicate the usefulness of the developed setup to determine the corrosion current density with and without Ohmic drop compensation. |
format | Article |
id | doaj-art-e5d67726350d4c2eb89f888cf8bc4945 |
institution | Kabale University |
issn | 2356-6140 1537-744X |
language | English |
publishDate | 2014-01-01 |
publisher | Wiley |
record_format | Article |
series | The Scientific World Journal |
spelling | doaj-art-e5d67726350d4c2eb89f888cf8bc49452025-02-03T06:00:56ZengWileyThe Scientific World Journal2356-61401537-744X2014-01-01201410.1155/2014/525678525678A Simple and Reliable Setup for Monitoring Corrosion Rate of Steel Rebars in ConcreteShamsad Ahmad0Mohammed Abdul Azeem Jibran1Abul Kalam Azad2Mohammed Maslehuddin3Civil and Environmental Engineering Department, King Fahd University of Petroleum and Minerals, P.O. Box 1403, Dhahran 31261, Saudi ArabiaCivil and Environmental Engineering Department, King Fahd University of Petroleum and Minerals, P.O. Box 1403, Dhahran 31261, Saudi ArabiaCivil and Environmental Engineering Department, King Fahd University of Petroleum and Minerals, P.O. Box 1403, Dhahran 31261, Saudi ArabiaCivil and Environmental Engineering Department, King Fahd University of Petroleum and Minerals, P.O. Box 1403, Dhahran 31261, Saudi ArabiaThe accuracy in the measurement of the rate of corrosion of steel in concrete depends on many factors. The high resistivity of concrete makes the polarization data erroneous due to the Ohmic drop. The other source of error is the use of an arbitrarily assumed value of the Stern-Geary constant for calculating corrosion current density. This paper presents the outcomes of a research work conducted to develop a reliable and low-cost experimental setup and a simple calculation procedure that can be utilised to calculate the corrosion current density considering the Ohmic drop compensation and the actual value of the Stern-Geary constants calculated using the polarization data. The measurements conducted on specimens corroded to different levels indicate the usefulness of the developed setup to determine the corrosion current density with and without Ohmic drop compensation.http://dx.doi.org/10.1155/2014/525678 |
spellingShingle | Shamsad Ahmad Mohammed Abdul Azeem Jibran Abul Kalam Azad Mohammed Maslehuddin A Simple and Reliable Setup for Monitoring Corrosion Rate of Steel Rebars in Concrete The Scientific World Journal |
title | A Simple and Reliable Setup for Monitoring Corrosion Rate of Steel Rebars in Concrete |
title_full | A Simple and Reliable Setup for Monitoring Corrosion Rate of Steel Rebars in Concrete |
title_fullStr | A Simple and Reliable Setup for Monitoring Corrosion Rate of Steel Rebars in Concrete |
title_full_unstemmed | A Simple and Reliable Setup for Monitoring Corrosion Rate of Steel Rebars in Concrete |
title_short | A Simple and Reliable Setup for Monitoring Corrosion Rate of Steel Rebars in Concrete |
title_sort | simple and reliable setup for monitoring corrosion rate of steel rebars in concrete |
url | http://dx.doi.org/10.1155/2014/525678 |
work_keys_str_mv | AT shamsadahmad asimpleandreliablesetupformonitoringcorrosionrateofsteelrebarsinconcrete AT mohammedabdulazeemjibran asimpleandreliablesetupformonitoringcorrosionrateofsteelrebarsinconcrete AT abulkalamazad asimpleandreliablesetupformonitoringcorrosionrateofsteelrebarsinconcrete AT mohammedmaslehuddin asimpleandreliablesetupformonitoringcorrosionrateofsteelrebarsinconcrete AT shamsadahmad simpleandreliablesetupformonitoringcorrosionrateofsteelrebarsinconcrete AT mohammedabdulazeemjibran simpleandreliablesetupformonitoringcorrosionrateofsteelrebarsinconcrete AT abulkalamazad simpleandreliablesetupformonitoringcorrosionrateofsteelrebarsinconcrete AT mohammedmaslehuddin simpleandreliablesetupformonitoringcorrosionrateofsteelrebarsinconcrete |