Correlations among Corneal Biomechanical Parameters, Stiffness, and Thickness Measured Using Corvis ST and Pentacam in Patients with Ocular Hypertension

Background. To preliminary explore the correlations among corneal biomechanical parameters, stiffness, and thickness in patients with ocular hypertension (OHT) before and after treatment with topical antiglaucoma medications. Methods. This was a retrospective study that included 35 eyes with newly d...

Full description

Saved in:
Bibliographic Details
Main Authors: Qian Liu, Chenjiu Pang, Changgeng Liu, Wenjun Cheng, Shuai Ming, Wenwen Du, Xiaomei Feng
Format: Article
Language:English
Published: Wiley 2022-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2022/7387581
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850168060214771712
author Qian Liu
Chenjiu Pang
Changgeng Liu
Wenjun Cheng
Shuai Ming
Wenwen Du
Xiaomei Feng
author_facet Qian Liu
Chenjiu Pang
Changgeng Liu
Wenjun Cheng
Shuai Ming
Wenwen Du
Xiaomei Feng
author_sort Qian Liu
collection DOAJ
description Background. To preliminary explore the correlations among corneal biomechanical parameters, stiffness, and thickness in patients with ocular hypertension (OHT) before and after treatment with topical antiglaucoma medications. Methods. This was a retrospective study that included 35 eyes with newly diagnosed OHT. Axial length (AL), apical corneal thickness, and minimum corneal thickness were measured using Pentacam. The lengths, velocities, and times of the first and second corneal applanations (A1L, A1V, A1T, A2L, A2V, and A2T, respectively); the highest concavity radius; highest concavity peak distance (PDHC); highest concavity deformation amplitude (DAHC); highest concavity time (HCT); pachymetry (PACH); stress-strain index (SSI); stiffness parameter-A1 (SP-A1); deformation amplitude ratio (DA ratio); integrated radius (IR); Ambrosio’s relational thickness horizontal (ARTh); corneal biomechanical index; noncorrected intraocular pressure (IOPnct); and biomechanically corrected IOP (bIOP) values were measured using the corneal visualization Scheimpflug technology (Corvis ST/CST). Results. After 5 weeks of treatment, Goldman applanation tonometer-IOP, IOPnct, bIOP, PACH, A1T, A2V, SSI, SP-A1, and ARTh decreased, but A1V, A2T, PDHC, DAHC, DA ratio, and IR increased significantly (all p<0.05). SP-A1 and A1T were positively associated with premedication IOP and IOP changes, whereas A1V, A2T, PDHC, and IR were negatively associated (all p<0.05). DAHC and DA ratio had significantly negative correlations with IOP variations. PDHC was found to be positively correlated with AL (p<0.05). A positive relationship was noted between SP-A1 and HCT before medication (p<0.05). Conclusions. SP-A1 was significantly and consistently associated with IOP. HCT might be correlated with SP-A1. SP-A1 and CST parameters could serve as potential biomarkers for evaluating OHT treatment efficacy.
format Article
id doaj-art-e5ccf0701e994c599a0415ba1d2c0b9d
institution OA Journals
issn 2090-0058
language English
publishDate 2022-01-01
publisher Wiley
record_format Article
series Journal of Ophthalmology
spelling doaj-art-e5ccf0701e994c599a0415ba1d2c0b9d2025-08-20T02:21:03ZengWileyJournal of Ophthalmology2090-00582022-01-01202210.1155/2022/7387581Correlations among Corneal Biomechanical Parameters, Stiffness, and Thickness Measured Using Corvis ST and Pentacam in Patients with Ocular HypertensionQian Liu0Chenjiu Pang1Changgeng Liu2Wenjun Cheng3Shuai Ming4Wenwen Du5Xiaomei Feng6Henan Provincial People’s HospitalHenan Provincial People’s HospitalHenan Provincial People’s HospitalHenan Provincial People’s HospitalHenan Provincial People’s HospitalHenan Provincial People’s HospitalHenan Provincial People’s HospitalBackground. To preliminary explore the correlations among corneal biomechanical parameters, stiffness, and thickness in patients with ocular hypertension (OHT) before and after treatment with topical antiglaucoma medications. Methods. This was a retrospective study that included 35 eyes with newly diagnosed OHT. Axial length (AL), apical corneal thickness, and minimum corneal thickness were measured using Pentacam. The lengths, velocities, and times of the first and second corneal applanations (A1L, A1V, A1T, A2L, A2V, and A2T, respectively); the highest concavity radius; highest concavity peak distance (PDHC); highest concavity deformation amplitude (DAHC); highest concavity time (HCT); pachymetry (PACH); stress-strain index (SSI); stiffness parameter-A1 (SP-A1); deformation amplitude ratio (DA ratio); integrated radius (IR); Ambrosio’s relational thickness horizontal (ARTh); corneal biomechanical index; noncorrected intraocular pressure (IOPnct); and biomechanically corrected IOP (bIOP) values were measured using the corneal visualization Scheimpflug technology (Corvis ST/CST). Results. After 5 weeks of treatment, Goldman applanation tonometer-IOP, IOPnct, bIOP, PACH, A1T, A2V, SSI, SP-A1, and ARTh decreased, but A1V, A2T, PDHC, DAHC, DA ratio, and IR increased significantly (all p<0.05). SP-A1 and A1T were positively associated with premedication IOP and IOP changes, whereas A1V, A2T, PDHC, and IR were negatively associated (all p<0.05). DAHC and DA ratio had significantly negative correlations with IOP variations. PDHC was found to be positively correlated with AL (p<0.05). A positive relationship was noted between SP-A1 and HCT before medication (p<0.05). Conclusions. SP-A1 was significantly and consistently associated with IOP. HCT might be correlated with SP-A1. SP-A1 and CST parameters could serve as potential biomarkers for evaluating OHT treatment efficacy.http://dx.doi.org/10.1155/2022/7387581
spellingShingle Qian Liu
Chenjiu Pang
Changgeng Liu
Wenjun Cheng
Shuai Ming
Wenwen Du
Xiaomei Feng
Correlations among Corneal Biomechanical Parameters, Stiffness, and Thickness Measured Using Corvis ST and Pentacam in Patients with Ocular Hypertension
Journal of Ophthalmology
title Correlations among Corneal Biomechanical Parameters, Stiffness, and Thickness Measured Using Corvis ST and Pentacam in Patients with Ocular Hypertension
title_full Correlations among Corneal Biomechanical Parameters, Stiffness, and Thickness Measured Using Corvis ST and Pentacam in Patients with Ocular Hypertension
title_fullStr Correlations among Corneal Biomechanical Parameters, Stiffness, and Thickness Measured Using Corvis ST and Pentacam in Patients with Ocular Hypertension
title_full_unstemmed Correlations among Corneal Biomechanical Parameters, Stiffness, and Thickness Measured Using Corvis ST and Pentacam in Patients with Ocular Hypertension
title_short Correlations among Corneal Biomechanical Parameters, Stiffness, and Thickness Measured Using Corvis ST and Pentacam in Patients with Ocular Hypertension
title_sort correlations among corneal biomechanical parameters stiffness and thickness measured using corvis st and pentacam in patients with ocular hypertension
url http://dx.doi.org/10.1155/2022/7387581
work_keys_str_mv AT qianliu correlationsamongcornealbiomechanicalparametersstiffnessandthicknessmeasuredusingcorvisstandpentacaminpatientswithocularhypertension
AT chenjiupang correlationsamongcornealbiomechanicalparametersstiffnessandthicknessmeasuredusingcorvisstandpentacaminpatientswithocularhypertension
AT changgengliu correlationsamongcornealbiomechanicalparametersstiffnessandthicknessmeasuredusingcorvisstandpentacaminpatientswithocularhypertension
AT wenjuncheng correlationsamongcornealbiomechanicalparametersstiffnessandthicknessmeasuredusingcorvisstandpentacaminpatientswithocularhypertension
AT shuaiming correlationsamongcornealbiomechanicalparametersstiffnessandthicknessmeasuredusingcorvisstandpentacaminpatientswithocularhypertension
AT wenwendu correlationsamongcornealbiomechanicalparametersstiffnessandthicknessmeasuredusingcorvisstandpentacaminpatientswithocularhypertension
AT xiaomeifeng correlationsamongcornealbiomechanicalparametersstiffnessandthicknessmeasuredusingcorvisstandpentacaminpatientswithocularhypertension