REGIMES OF 110—330 KV SINGLE-CIRCUIT OVERHEAD TRANSMISSION LINES WITH REDUNDANT PHASE

To improve the performance reliability of the overhead power lines, a redundant phase that can reserve any of the damaged phase conductor, and allow single-phase fusing glaze-ice and rime depositions with conservation of the consumer supply continuity is offered for use. The mode analysis and the su...

Full description

Saved in:
Bibliographic Details
Main Author: Dmitry Sergeyevich Levin
Format: Article
Language:Russian
Published: Don State Technical University 2013-03-01
Series:Advanced Engineering Research
Subjects:
Online Access:https://www.vestnik-donstu.ru/jour/article/view/379
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849250570441850880
author Dmitry Sergeyevich Levin
author_facet Dmitry Sergeyevich Levin
author_sort Dmitry Sergeyevich Levin
collection DOAJ
description To improve the performance reliability of the overhead power lines, a redundant phase that can reserve any of the damaged phase conductor, and allow single-phase fusing glaze-ice and rime depositions with conservation of the consumer supply continuity is offered for use. The mode analysis and the subsequent rationale are performed on the basis of the obtained data, the application possibility of the redundant phase for the overhead power lines with 110—330 kV voltage rating without the substantial power quality damage. As a redundant phase, the ground wire with phase conductor parameters and phase insulation is used. It serves to protect overhead circuits from the atmospheric overvoltage in thunderstorm seasons, and as a redundant fourth wire — during the rest of the time. In Matlab (Simulink) program, an electrodynamical simulation model is developed, and the operating regime parameters of the overhead circuit using the fourth wire as a redundant phase are analyzed.
format Article
id doaj-art-e59b159a083a41629cf0f3c0f07d79a2
institution Kabale University
issn 2687-1653
language Russian
publishDate 2013-03-01
publisher Don State Technical University
record_format Article
series Advanced Engineering Research
spelling doaj-art-e59b159a083a41629cf0f3c0f07d79a22025-08-20T03:57:12ZrusDon State Technical UniversityAdvanced Engineering Research2687-16532013-03-01131-29396372REGIMES OF 110—330 KV SINGLE-CIRCUIT OVERHEAD TRANSMISSION LINES WITH REDUNDANT PHASEDmitry Sergeyevich Levin0Saratov State Technical University. RussiaTo improve the performance reliability of the overhead power lines, a redundant phase that can reserve any of the damaged phase conductor, and allow single-phase fusing glaze-ice and rime depositions with conservation of the consumer supply continuity is offered for use. The mode analysis and the subsequent rationale are performed on the basis of the obtained data, the application possibility of the redundant phase for the overhead power lines with 110—330 kV voltage rating without the substantial power quality damage. As a redundant phase, the ground wire with phase conductor parameters and phase insulation is used. It serves to protect overhead circuits from the atmospheric overvoltage in thunderstorm seasons, and as a redundant fourth wire — during the rest of the time. In Matlab (Simulink) program, an electrodynamical simulation model is developed, and the operating regime parameters of the overhead circuit using the fourth wire as a redundant phase are analyzed.https://www.vestnik-donstu.ru/jour/article/view/379redundant phase, ground wire, fourth wire, glaze-ice and rime depositions, single-phase fusion, overhead transmission line.
spellingShingle Dmitry Sergeyevich Levin
REGIMES OF 110—330 KV SINGLE-CIRCUIT OVERHEAD TRANSMISSION LINES WITH REDUNDANT PHASE
Advanced Engineering Research
redundant phase, ground wire, fourth wire, glaze-ice and rime depositions, single-phase fusion, overhead transmission line.
title REGIMES OF 110—330 KV SINGLE-CIRCUIT OVERHEAD TRANSMISSION LINES WITH REDUNDANT PHASE
title_full REGIMES OF 110—330 KV SINGLE-CIRCUIT OVERHEAD TRANSMISSION LINES WITH REDUNDANT PHASE
title_fullStr REGIMES OF 110—330 KV SINGLE-CIRCUIT OVERHEAD TRANSMISSION LINES WITH REDUNDANT PHASE
title_full_unstemmed REGIMES OF 110—330 KV SINGLE-CIRCUIT OVERHEAD TRANSMISSION LINES WITH REDUNDANT PHASE
title_short REGIMES OF 110—330 KV SINGLE-CIRCUIT OVERHEAD TRANSMISSION LINES WITH REDUNDANT PHASE
title_sort regimes of 110 330 kv single circuit overhead transmission lines with redundant phase
topic redundant phase, ground wire, fourth wire, glaze-ice and rime depositions, single-phase fusion, overhead transmission line.
url https://www.vestnik-donstu.ru/jour/article/view/379
work_keys_str_mv AT dmitrysergeyevichlevin regimesof110330kvsinglecircuitoverheadtransmissionlineswithredundantphase