Multi-level adaptive coordinated AC fault ride-through control strategy for hybrid cascaded UHVDC transmission system

Hybrid cascaded ultra high voltage direct current (UHVDC) integrates the advantages of line commutated converters (LCC) and voltage source converters (VSC). However, there is surplus power on the direct current (DC) side during alternating current (AC) faults at the receiving end, which may cause ov...

Full description

Saved in:
Bibliographic Details
Main Authors: LYU Yanbei, ZHAO Wenqiang, SHI Qiaoming, YAO Qixin, SUI Shunke, CHANG Haotian
Format: Article
Language:zho
Published: Editorial Department of Electric Power Engineering Technology 2025-01-01
Series:电力工程技术
Subjects:
Online Access:https://www.epet-info.com/dlgcjsen/article/abstract/230906109
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823865323980324864
author LYU Yanbei
ZHAO Wenqiang
SHI Qiaoming
YAO Qixin
SUI Shunke
CHANG Haotian
author_facet LYU Yanbei
ZHAO Wenqiang
SHI Qiaoming
YAO Qixin
SUI Shunke
CHANG Haotian
author_sort LYU Yanbei
collection DOAJ
description Hybrid cascaded ultra high voltage direct current (UHVDC) integrates the advantages of line commutated converters (LCC) and voltage source converters (VSC). However, there is surplus power on the direct current (DC) side during alternating current (AC) faults at the receiving end, which may cause overvoltage issues in VSC sub-modules. Based on the topological features of the hybrid cascaded UHVDC system, a multi-level adaptive coordinated control strategy is proposed, utilizing operation modes and electrical signals. Multi-level control strategies, namely controlling the negative sequence voltage of the faulty VSC converter, adopting the auxiliary DC voltage control of the sound VSC converters, switching on the controllable energy dissipation devices at the receiving end and retarding of the LCC converters at the sending end, adjusting the DC power of the converters at the sending and receiving ends, are adaptively coordinated within converters, between converters and between stations to effectively mitigate the overvoltage issues in VSC sub-modules and realize AC fault ride-through of the hybrid cascaded UHVDC system. A closed-loop real-time digital simulation test platform is built based on actual control and protection devices and the topology used on site. The test results show the validity of the proposed strategy. The proposed strategy has been successfully applied in the Baihetan-Jiangsu hybrid UHVDC project.
format Article
id doaj-art-e56f2132d31247f5b1a27867885152c0
institution Kabale University
issn 2096-3203
language zho
publishDate 2025-01-01
publisher Editorial Department of Electric Power Engineering Technology
record_format Article
series 电力工程技术
spelling doaj-art-e56f2132d31247f5b1a27867885152c02025-02-08T08:40:18ZzhoEditorial Department of Electric Power Engineering Technology电力工程技术2096-32032025-01-0144116517410.12158/j.2096-3203.2025.01.017230906109Multi-level adaptive coordinated AC fault ride-through control strategy for hybrid cascaded UHVDC transmission systemLYU Yanbei0ZHAO Wenqiang1SHI Qiaoming2YAO Qixin3SUI Shunke4CHANG Haotian5Nanjing NR Electric Co., Ltd., Nanjing 211102, ChinaNanjing NR Electric Co., Ltd., Nanjing 211102, ChinaNanjing NR Electric Co., Ltd., Nanjing 211102, ChinaState Grid Hubei Electric Power Co., Ltd. Direct Current Company, Yichang 443000, ChinaNanjing NR Electric Co., Ltd., Nanjing 211102, ChinaNanjing NR Electric Co., Ltd., Nanjing 211102, ChinaHybrid cascaded ultra high voltage direct current (UHVDC) integrates the advantages of line commutated converters (LCC) and voltage source converters (VSC). However, there is surplus power on the direct current (DC) side during alternating current (AC) faults at the receiving end, which may cause overvoltage issues in VSC sub-modules. Based on the topological features of the hybrid cascaded UHVDC system, a multi-level adaptive coordinated control strategy is proposed, utilizing operation modes and electrical signals. Multi-level control strategies, namely controlling the negative sequence voltage of the faulty VSC converter, adopting the auxiliary DC voltage control of the sound VSC converters, switching on the controllable energy dissipation devices at the receiving end and retarding of the LCC converters at the sending end, adjusting the DC power of the converters at the sending and receiving ends, are adaptively coordinated within converters, between converters and between stations to effectively mitigate the overvoltage issues in VSC sub-modules and realize AC fault ride-through of the hybrid cascaded UHVDC system. A closed-loop real-time digital simulation test platform is built based on actual control and protection devices and the topology used on site. The test results show the validity of the proposed strategy. The proposed strategy has been successfully applied in the Baihetan-Jiangsu hybrid UHVDC project.https://www.epet-info.com/dlgcjsen/article/abstract/230906109ultra high voltage direct current (uhvdc)hybrid cascaded topologymulti-level adaptivefault ride-throughsub-module overvoltage 
spellingShingle LYU Yanbei
ZHAO Wenqiang
SHI Qiaoming
YAO Qixin
SUI Shunke
CHANG Haotian
Multi-level adaptive coordinated AC fault ride-through control strategy for hybrid cascaded UHVDC transmission system
电力工程技术
ultra high voltage direct current (uhvdc)
hybrid cascaded topology
multi-level adaptive
fault ride-through
sub-module overvoltage
 
title Multi-level adaptive coordinated AC fault ride-through control strategy for hybrid cascaded UHVDC transmission system
title_full Multi-level adaptive coordinated AC fault ride-through control strategy for hybrid cascaded UHVDC transmission system
title_fullStr Multi-level adaptive coordinated AC fault ride-through control strategy for hybrid cascaded UHVDC transmission system
title_full_unstemmed Multi-level adaptive coordinated AC fault ride-through control strategy for hybrid cascaded UHVDC transmission system
title_short Multi-level adaptive coordinated AC fault ride-through control strategy for hybrid cascaded UHVDC transmission system
title_sort multi level adaptive coordinated ac fault ride through control strategy for hybrid cascaded uhvdc transmission system
topic ultra high voltage direct current (uhvdc)
hybrid cascaded topology
multi-level adaptive
fault ride-through
sub-module overvoltage
 
url https://www.epet-info.com/dlgcjsen/article/abstract/230906109
work_keys_str_mv AT lyuyanbei multileveladaptivecoordinatedacfaultridethroughcontrolstrategyforhybridcascadeduhvdctransmissionsystem
AT zhaowenqiang multileveladaptivecoordinatedacfaultridethroughcontrolstrategyforhybridcascadeduhvdctransmissionsystem
AT shiqiaoming multileveladaptivecoordinatedacfaultridethroughcontrolstrategyforhybridcascadeduhvdctransmissionsystem
AT yaoqixin multileveladaptivecoordinatedacfaultridethroughcontrolstrategyforhybridcascadeduhvdctransmissionsystem
AT suishunke multileveladaptivecoordinatedacfaultridethroughcontrolstrategyforhybridcascadeduhvdctransmissionsystem
AT changhaotian multileveladaptivecoordinatedacfaultridethroughcontrolstrategyforhybridcascadeduhvdctransmissionsystem