Effectiveness of thinner polyvinyl alcohol fibers on mechanical properties and cost effectiveness of office automation floor panels.

Floor finishing is the final and crucial stage in building construction. Flooring materials must possess strength, insulation, durability, aesthetics, and comfort. Office buildings typically use raised floor systems, known as office automation (OA) floors, which utilize various panel types for insul...

Full description

Saved in:
Bibliographic Details
Main Author: Tek Raj Gyawali
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2025-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0324126
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849325300600537088
author Tek Raj Gyawali
author_facet Tek Raj Gyawali
author_sort Tek Raj Gyawali
collection DOAJ
description Floor finishing is the final and crucial stage in building construction. Flooring materials must possess strength, insulation, durability, aesthetics, and comfort. Office buildings typically use raised floor systems, known as office automation (OA) floors, which utilize various panel types for insulation and wiring purposes. Polyvinyl alcohol (PVA) fiber-reinforced mortar, with a water-cement (W/C) ratio of 0.30, a cement-sand (C:S) ratio of 1:0.776, and a fiber content of 3.0% by volume (fiber size: Ф100µm × 12mm), is mechanically pressed with water dehydration to create OA floor panels measuring 500 mm in length and width and 23 mm in thickness. A W/C ratio of 0.32 was maintained to achieve the same workability for producing panels using thinner PVA fibers (fiber size: Ф40µm × 12mm). A comparative analysis of both panel types was conducted, focusing on mechanical properties and costs. Panels reinforced with thinner PVA fibers exhibited superior performance in resisting compressive and impact loads. This enabled a reduction in fiber content to 1.2% (a 60% decrease) and panel thickness to 22 mm (a 4.35% decrease) compared to panels with thicker fibers. Consequently, the cost of panels with thinner fibers was reduced by 43.9%. The findings demonstrate that thinner PVA fibers are a viable replacement for thicker fibers in conventional OA floor panels, significantly reducing costs while meeting the required mechanical properties. The implementation of these findings in real OA floor factories reduces the consumption of PVA fibers and cement, contributing to sustainable development by lowering the carbon footprint, which is primarily generated during the production of cement and PVA fibers.
format Article
id doaj-art-e55bcb66c1434bcc8d9f1eaa04ccc93b
institution Kabale University
issn 1932-6203
language English
publishDate 2025-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj-art-e55bcb66c1434bcc8d9f1eaa04ccc93b2025-08-20T03:48:27ZengPublic Library of Science (PLoS)PLoS ONE1932-62032025-01-01205e032412610.1371/journal.pone.0324126Effectiveness of thinner polyvinyl alcohol fibers on mechanical properties and cost effectiveness of office automation floor panels.Tek Raj GyawaliFloor finishing is the final and crucial stage in building construction. Flooring materials must possess strength, insulation, durability, aesthetics, and comfort. Office buildings typically use raised floor systems, known as office automation (OA) floors, which utilize various panel types for insulation and wiring purposes. Polyvinyl alcohol (PVA) fiber-reinforced mortar, with a water-cement (W/C) ratio of 0.30, a cement-sand (C:S) ratio of 1:0.776, and a fiber content of 3.0% by volume (fiber size: Ф100µm × 12mm), is mechanically pressed with water dehydration to create OA floor panels measuring 500 mm in length and width and 23 mm in thickness. A W/C ratio of 0.32 was maintained to achieve the same workability for producing panels using thinner PVA fibers (fiber size: Ф40µm × 12mm). A comparative analysis of both panel types was conducted, focusing on mechanical properties and costs. Panels reinforced with thinner PVA fibers exhibited superior performance in resisting compressive and impact loads. This enabled a reduction in fiber content to 1.2% (a 60% decrease) and panel thickness to 22 mm (a 4.35% decrease) compared to panels with thicker fibers. Consequently, the cost of panels with thinner fibers was reduced by 43.9%. The findings demonstrate that thinner PVA fibers are a viable replacement for thicker fibers in conventional OA floor panels, significantly reducing costs while meeting the required mechanical properties. The implementation of these findings in real OA floor factories reduces the consumption of PVA fibers and cement, contributing to sustainable development by lowering the carbon footprint, which is primarily generated during the production of cement and PVA fibers.https://doi.org/10.1371/journal.pone.0324126
spellingShingle Tek Raj Gyawali
Effectiveness of thinner polyvinyl alcohol fibers on mechanical properties and cost effectiveness of office automation floor panels.
PLoS ONE
title Effectiveness of thinner polyvinyl alcohol fibers on mechanical properties and cost effectiveness of office automation floor panels.
title_full Effectiveness of thinner polyvinyl alcohol fibers on mechanical properties and cost effectiveness of office automation floor panels.
title_fullStr Effectiveness of thinner polyvinyl alcohol fibers on mechanical properties and cost effectiveness of office automation floor panels.
title_full_unstemmed Effectiveness of thinner polyvinyl alcohol fibers on mechanical properties and cost effectiveness of office automation floor panels.
title_short Effectiveness of thinner polyvinyl alcohol fibers on mechanical properties and cost effectiveness of office automation floor panels.
title_sort effectiveness of thinner polyvinyl alcohol fibers on mechanical properties and cost effectiveness of office automation floor panels
url https://doi.org/10.1371/journal.pone.0324126
work_keys_str_mv AT tekrajgyawali effectivenessofthinnerpolyvinylalcoholfibersonmechanicalpropertiesandcosteffectivenessofofficeautomationfloorpanels