POSSIBLE ERRORS OF CALCULATIONS OF LOSSES OF THE ELECTRIC POWER ON SHOP INDUSTRIAL NETWORKS

In the article it is devoted the analysis and researches of origins and values of possible errors from not accounting of the main defining characteristics when calculating losses of the electric power on shop networks of a low tension. It is proved that in case of determination of losses of the elec...

Full description

Saved in:
Bibliographic Details
Main Authors: E. I. Gracheva, A. N. Alimova
Format: Article
Language:English
Published: Kazan State Power Engineering University 2019-02-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/807
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850066958649655296
author E. I. Gracheva
A. N. Alimova
author_facet E. I. Gracheva
A. N. Alimova
author_sort E. I. Gracheva
collection DOAJ
description In the article it is devoted the analysis and researches of origins and values of possible errors from not accounting of the main defining characteristics when calculating losses of the electric power on shop networks of a low tension. It is proved that in case of determination of losses of the electric power in lines of shop networks it is necessary to consider influence of the following parameters of the equipment: the heating of conductors caused by passing of current of loading through conductors and ambient temperature; resistance of contact joints of switching devices and their number; type of the load graph; ambient temperatures. The diagram of a shop network and daily load graphs of customers of one of the enterprises is researched. Errors of calculations of losses of the electric power are calculated and the analysis of influence of parameters of the equipment on value of losses of the electric power is carried out. The absence of reliable information about elements of shop networks of a low tension and not accounting of the determining leads to an error 5 - 80% in case of computation of losses of the electric power in the systems of industrial electrical power supply.
format Article
id doaj-art-e5314bd401174aef9338896aedb0337e
institution DOAJ
issn 1998-9903
language English
publishDate 2019-02-01
publisher Kazan State Power Engineering University
record_format Article
series Известия высших учебных заведений: Проблемы энергетики
spelling doaj-art-e5314bd401174aef9338896aedb0337e2025-08-20T02:48:33ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032019-02-012011-12819210.30724/1998-9903-2018-20-11-12-81-92542POSSIBLE ERRORS OF CALCULATIONS OF LOSSES OF THE ELECTRIC POWER ON SHOP INDUSTRIAL NETWORKSE. I. Gracheva0A. N. Alimova1Kazan state power-engineering university, KazanKazan state power-engineering university, KazanIn the article it is devoted the analysis and researches of origins and values of possible errors from not accounting of the main defining characteristics when calculating losses of the electric power on shop networks of a low tension. It is proved that in case of determination of losses of the electric power in lines of shop networks it is necessary to consider influence of the following parameters of the equipment: the heating of conductors caused by passing of current of loading through conductors and ambient temperature; resistance of contact joints of switching devices and their number; type of the load graph; ambient temperatures. The diagram of a shop network and daily load graphs of customers of one of the enterprises is researched. Errors of calculations of losses of the electric power are calculated and the analysis of influence of parameters of the equipment on value of losses of the electric power is carried out. The absence of reliable information about elements of shop networks of a low tension and not accounting of the determining leads to an error 5 - 80% in case of computation of losses of the electric power in the systems of industrial electrical power supply.https://www.energyret.ru/jour/article/view/807electric equipment of shopsconfigurationload graphslosses of the electric powerwire temperatureambient temperatureresistance of contact joints of switching devices and their numbersdaily load graphs.
spellingShingle E. I. Gracheva
A. N. Alimova
POSSIBLE ERRORS OF CALCULATIONS OF LOSSES OF THE ELECTRIC POWER ON SHOP INDUSTRIAL NETWORKS
Известия высших учебных заведений: Проблемы энергетики
electric equipment of shops
configuration
load graphs
losses of the electric power
wire temperature
ambient temperature
resistance of contact joints of switching devices and their numbers
daily load graphs.
title POSSIBLE ERRORS OF CALCULATIONS OF LOSSES OF THE ELECTRIC POWER ON SHOP INDUSTRIAL NETWORKS
title_full POSSIBLE ERRORS OF CALCULATIONS OF LOSSES OF THE ELECTRIC POWER ON SHOP INDUSTRIAL NETWORKS
title_fullStr POSSIBLE ERRORS OF CALCULATIONS OF LOSSES OF THE ELECTRIC POWER ON SHOP INDUSTRIAL NETWORKS
title_full_unstemmed POSSIBLE ERRORS OF CALCULATIONS OF LOSSES OF THE ELECTRIC POWER ON SHOP INDUSTRIAL NETWORKS
title_short POSSIBLE ERRORS OF CALCULATIONS OF LOSSES OF THE ELECTRIC POWER ON SHOP INDUSTRIAL NETWORKS
title_sort possible errors of calculations of losses of the electric power on shop industrial networks
topic electric equipment of shops
configuration
load graphs
losses of the electric power
wire temperature
ambient temperature
resistance of contact joints of switching devices and their numbers
daily load graphs.
url https://www.energyret.ru/jour/article/view/807
work_keys_str_mv AT eigracheva possibleerrorsofcalculationsoflossesoftheelectricpoweronshopindustrialnetworks
AT analimova possibleerrorsofcalculationsoflossesoftheelectricpoweronshopindustrialnetworks