Intraoperative computed tomography-guided robotic needle biopsy system with real-time imaging ability and remote-center-of-motion control

Objective Traditional computed tomography (CT)-guided tumor ablation procedures are often hampered by the need for repeated scans and significant radiation exposure, primarily due to challenges in manual needle insertion and the iterative realignment process. This research introduces an advanced int...

Full description

Saved in:
Bibliographic Details
Main Authors: Zheng-Yang Lai, Chun-Ting Kuo, Shun-Mao Yang, Ming-Chih Ho, Yung-Yaw Chen, Tsu-Chin Tsao, Jia-Yush Yen
Format: Article
Language:English
Published: SAGE Publishing 2025-05-01
Series:International Journal of Advanced Robotic Systems
Online Access:https://doi.org/10.1177/17298806251352059
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849424641419902976
author Zheng-Yang Lai
Chun-Ting Kuo
Shun-Mao Yang
Ming-Chih Ho
Yung-Yaw Chen
Tsu-Chin Tsao
Jia-Yush Yen
author_facet Zheng-Yang Lai
Chun-Ting Kuo
Shun-Mao Yang
Ming-Chih Ho
Yung-Yaw Chen
Tsu-Chin Tsao
Jia-Yush Yen
author_sort Zheng-Yang Lai
collection DOAJ
description Objective Traditional computed tomography (CT)-guided tumor ablation procedures are often hampered by the need for repeated scans and significant radiation exposure, primarily due to challenges in manual needle insertion and the iterative realignment process. This research introduces an advanced intraoperative CT (iCT)-guided robotic system. The core aim is to enhance procedural accuracy and efficiency by implementing precise, real-time remote-center-of-motion (RCM) control for needle interventions. Methods This study develops an integrated iCT-guided robotic needle biopsy/ablation system. A key distinction from conventional iterative navigation systems is their capability for surgeons to dynamically adjust the intervention line in situ. Real-time visualization of relative positioning is achieved using 3D (three-dimensional) Slicer software. This is coupled with a novel and robust RCM control strategy, meticulously engineered based on screw axis theory and velocity twist, and further optimized with interpolation and feedforward control laws. This framework enables precise, surgeon-guided adjustments of the guiding catheter's posture throughout the procedure. Results The RCM control system effectively and reliably governed the motion of the robotic guidance arm. This ensured that the catheter tube consistently maintained its accurate orientation relative to the target even after multiple surgeon-adjusted posture modifications. Experimental validation demonstrated the system's high performance, achieving exceptionally low RCM errors as 2×10 −4 m. Consequently, any deliberate pause during the robotic arm's movement could be utilized to define a precisely targeted and safe puncture path. Conclusion and significance Comprehensive numerical modeling and experimental evaluations using a TM5-700 robotic arm with phantoms have provided validation for the proposed screw axis-based RCM control concept. Integrating iCT guidance with this RCM system indicates increased precision, operational flexibility, and overall safety of robotic needle-based interventions. This work presents a noteworthy contribution with potential for clinical adoption in various minimally invasive procedures.
format Article
id doaj-art-e4eff4c175c54b9a98c5cc783f406f58
institution Kabale University
issn 1729-8814
language English
publishDate 2025-05-01
publisher SAGE Publishing
record_format Article
series International Journal of Advanced Robotic Systems
spelling doaj-art-e4eff4c175c54b9a98c5cc783f406f582025-08-20T03:30:05ZengSAGE PublishingInternational Journal of Advanced Robotic Systems1729-88142025-05-012210.1177/17298806251352059Intraoperative computed tomography-guided robotic needle biopsy system with real-time imaging ability and remote-center-of-motion controlZheng-Yang Lai0Chun-Ting Kuo1Shun-Mao Yang2Ming-Chih Ho3Yung-Yaw Chen4Tsu-Chin Tsao5Jia-Yush Yen6 Department of Mechanical Engineering, , Taipei, Taiwan Department of Mechanical Engineering, , Taipei, Taiwan Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan Department of Electrical Engineering, , Taipei, Taiwan Mechanical and Aerospace Engineering, Samueli School of Engineering, UCLA, Los Angeles, CA, USA Department of Mechanical Engineering, , Taipei, TaiwanObjective Traditional computed tomography (CT)-guided tumor ablation procedures are often hampered by the need for repeated scans and significant radiation exposure, primarily due to challenges in manual needle insertion and the iterative realignment process. This research introduces an advanced intraoperative CT (iCT)-guided robotic system. The core aim is to enhance procedural accuracy and efficiency by implementing precise, real-time remote-center-of-motion (RCM) control for needle interventions. Methods This study develops an integrated iCT-guided robotic needle biopsy/ablation system. A key distinction from conventional iterative navigation systems is their capability for surgeons to dynamically adjust the intervention line in situ. Real-time visualization of relative positioning is achieved using 3D (three-dimensional) Slicer software. This is coupled with a novel and robust RCM control strategy, meticulously engineered based on screw axis theory and velocity twist, and further optimized with interpolation and feedforward control laws. This framework enables precise, surgeon-guided adjustments of the guiding catheter's posture throughout the procedure. Results The RCM control system effectively and reliably governed the motion of the robotic guidance arm. This ensured that the catheter tube consistently maintained its accurate orientation relative to the target even after multiple surgeon-adjusted posture modifications. Experimental validation demonstrated the system's high performance, achieving exceptionally low RCM errors as 2×10 −4 m. Consequently, any deliberate pause during the robotic arm's movement could be utilized to define a precisely targeted and safe puncture path. Conclusion and significance Comprehensive numerical modeling and experimental evaluations using a TM5-700 robotic arm with phantoms have provided validation for the proposed screw axis-based RCM control concept. Integrating iCT guidance with this RCM system indicates increased precision, operational flexibility, and overall safety of robotic needle-based interventions. This work presents a noteworthy contribution with potential for clinical adoption in various minimally invasive procedures.https://doi.org/10.1177/17298806251352059
spellingShingle Zheng-Yang Lai
Chun-Ting Kuo
Shun-Mao Yang
Ming-Chih Ho
Yung-Yaw Chen
Tsu-Chin Tsao
Jia-Yush Yen
Intraoperative computed tomography-guided robotic needle biopsy system with real-time imaging ability and remote-center-of-motion control
International Journal of Advanced Robotic Systems
title Intraoperative computed tomography-guided robotic needle biopsy system with real-time imaging ability and remote-center-of-motion control
title_full Intraoperative computed tomography-guided robotic needle biopsy system with real-time imaging ability and remote-center-of-motion control
title_fullStr Intraoperative computed tomography-guided robotic needle biopsy system with real-time imaging ability and remote-center-of-motion control
title_full_unstemmed Intraoperative computed tomography-guided robotic needle biopsy system with real-time imaging ability and remote-center-of-motion control
title_short Intraoperative computed tomography-guided robotic needle biopsy system with real-time imaging ability and remote-center-of-motion control
title_sort intraoperative computed tomography guided robotic needle biopsy system with real time imaging ability and remote center of motion control
url https://doi.org/10.1177/17298806251352059
work_keys_str_mv AT zhengyanglai intraoperativecomputedtomographyguidedroboticneedlebiopsysystemwithrealtimeimagingabilityandremotecenterofmotioncontrol
AT chuntingkuo intraoperativecomputedtomographyguidedroboticneedlebiopsysystemwithrealtimeimagingabilityandremotecenterofmotioncontrol
AT shunmaoyang intraoperativecomputedtomographyguidedroboticneedlebiopsysystemwithrealtimeimagingabilityandremotecenterofmotioncontrol
AT mingchihho intraoperativecomputedtomographyguidedroboticneedlebiopsysystemwithrealtimeimagingabilityandremotecenterofmotioncontrol
AT yungyawchen intraoperativecomputedtomographyguidedroboticneedlebiopsysystemwithrealtimeimagingabilityandremotecenterofmotioncontrol
AT tsuchintsao intraoperativecomputedtomographyguidedroboticneedlebiopsysystemwithrealtimeimagingabilityandremotecenterofmotioncontrol
AT jiayushyen intraoperativecomputedtomographyguidedroboticneedlebiopsysystemwithrealtimeimagingabilityandremotecenterofmotioncontrol