Concurrent Validation and Reference Values of Gluteus Medius Clinical Test
# Context The hip abductor muscles, mainly the gluteus medius, are responsible for controlling hip adduction in a closed kinetic chain. Frontal plane knee alignment, assessed during functional activities such squatting, jumping and running, may overload joint structures, like the anterior cruciate...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
North American Sports Medicine Institute
2021-04-01
|
Series: | International Journal of Sports Physical Therapy |
Online Access: | https://doi.org/10.26603/001c.21477 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1825196973520584704 |
---|---|
author | Amanda S S Teixeira Paula L Silva Sabrina P Cintra Fernanda Viegas Luciana D Mendonça Natália F N Bittencourt |
author_facet | Amanda S S Teixeira Paula L Silva Sabrina P Cintra Fernanda Viegas Luciana D Mendonça Natália F N Bittencourt |
author_sort | Amanda S S Teixeira |
collection | DOAJ |
description | # Context
The hip abductor muscles, mainly the gluteus medius, are responsible for controlling hip adduction in a closed kinetic chain. Frontal plane knee alignment, assessed during functional activities such squatting, jumping and running, may overload joint structures, like the anterior cruciate ligament and patellofemoral joint. The hand-held dynamometer is reliable and effective for testing the muscular strength of the hip abductors.
# Objectives
(1) To assess the concurrent validity between the gluteus medius clinical test and a maximum isometric force test of the hip abductors using the hand-held dynamometer; (2) to determine the intra and inter-examiner reliability for the application of the gluteus medius clinical test; and (3) to describe reference values of gluteus medius clinical test on a population of youth athletes.
# Design
Cross-sectional.
# Methods
Thirty healthy individuals were recruited for validity and reliability testing. On the first day, participants performed the maximal isometric test of the hip abductors, measured via hand-held dynamometry. On the following week, the gluteus medius clinical test was performed. Intraclass correlation coefficients (ICC~2,2~) were computed for the reliability analysis, with a 95% confidence interval. To generate reference values, the gluteus medius clinical test was performed on 273 athletes.
# Results
The results of this study indicated a weak positive correlation (r = 0.436, p = 0.001) between tests, which indicates that they examine different domains of gluteus medius muscle function, likely endurance and muscle strength. The magnitude of computed ICCs (\>0.95) indicates excellent intra- and inter-examiner reliability.
# Conclusion
The findings of the current study indicate that the gluteus medius clinical test is reliable and examines a domain of muscular function not fully captured by HHD. The clinical test developed in this study is low-cost and can be included for gluteus medius assessment.
# Level of evidence
Level 3. |
format | Article |
id | doaj-art-e4cfbe10ecf6426f92259911244bb7a6 |
institution | Kabale University |
issn | 2159-2896 |
language | English |
publishDate | 2021-04-01 |
publisher | North American Sports Medicine Institute |
record_format | Article |
series | International Journal of Sports Physical Therapy |
spelling | doaj-art-e4cfbe10ecf6426f92259911244bb7a62025-02-11T20:29:38ZengNorth American Sports Medicine InstituteInternational Journal of Sports Physical Therapy2159-28962021-04-01162Concurrent Validation and Reference Values of Gluteus Medius Clinical TestAmanda S S TeixeiraPaula L SilvaSabrina P CintraFernanda ViegasLuciana D MendonçaNatália F N Bittencourt# Context The hip abductor muscles, mainly the gluteus medius, are responsible for controlling hip adduction in a closed kinetic chain. Frontal plane knee alignment, assessed during functional activities such squatting, jumping and running, may overload joint structures, like the anterior cruciate ligament and patellofemoral joint. The hand-held dynamometer is reliable and effective for testing the muscular strength of the hip abductors. # Objectives (1) To assess the concurrent validity between the gluteus medius clinical test and a maximum isometric force test of the hip abductors using the hand-held dynamometer; (2) to determine the intra and inter-examiner reliability for the application of the gluteus medius clinical test; and (3) to describe reference values of gluteus medius clinical test on a population of youth athletes. # Design Cross-sectional. # Methods Thirty healthy individuals were recruited for validity and reliability testing. On the first day, participants performed the maximal isometric test of the hip abductors, measured via hand-held dynamometry. On the following week, the gluteus medius clinical test was performed. Intraclass correlation coefficients (ICC~2,2~) were computed for the reliability analysis, with a 95% confidence interval. To generate reference values, the gluteus medius clinical test was performed on 273 athletes. # Results The results of this study indicated a weak positive correlation (r = 0.436, p = 0.001) between tests, which indicates that they examine different domains of gluteus medius muscle function, likely endurance and muscle strength. The magnitude of computed ICCs (\>0.95) indicates excellent intra- and inter-examiner reliability. # Conclusion The findings of the current study indicate that the gluteus medius clinical test is reliable and examines a domain of muscular function not fully captured by HHD. The clinical test developed in this study is low-cost and can be included for gluteus medius assessment. # Level of evidence Level 3.https://doi.org/10.26603/001c.21477 |
spellingShingle | Amanda S S Teixeira Paula L Silva Sabrina P Cintra Fernanda Viegas Luciana D Mendonça Natália F N Bittencourt Concurrent Validation and Reference Values of Gluteus Medius Clinical Test International Journal of Sports Physical Therapy |
title | Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title_full | Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title_fullStr | Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title_full_unstemmed | Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title_short | Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title_sort | concurrent validation and reference values of gluteus medius clinical test |
url | https://doi.org/10.26603/001c.21477 |
work_keys_str_mv | AT amandassteixeira concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest AT paulalsilva concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest AT sabrinapcintra concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest AT fernandaviegas concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest AT lucianadmendonca concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest AT nataliafnbittencourt concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest |