Clinical study of a method for the receptor apparatus of the teeth protection at the stages of treatment with non-removable prosthesis designs

This article presents the results of clinical approbation of our proposed method for protecting the receptor apparatus of the teeth through a complex of domestic light-curing adhesive preparations and antihomotoxic drug “Traumeel”, the application of which was substantiated by experimental studies i...

Full description

Saved in:
Bibliographic Details
Main Authors: O. V. Voznyi, I. V. Yanishen, I. L. Diudina, V. H. Tomilin, A. V. Pohorila
Format: Article
Language:English
Published: Zaporizhzhia State Medical and Pharmaceutical University 2019-12-01
Series:Zaporožskij Medicinskij Žurnal
Subjects:
Online Access:http://zmj.zsmu.edu.ua/article/view/186596/187019
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849470340143513600
author O. V. Voznyi
I. V. Yanishen
I. L. Diudina
V. H. Tomilin
A. V. Pohorila
author_facet O. V. Voznyi
I. V. Yanishen
I. L. Diudina
V. H. Tomilin
A. V. Pohorila
author_sort O. V. Voznyi
collection DOAJ
description This article presents the results of clinical approbation of our proposed method for protecting the receptor apparatus of the teeth through a complex of domestic light-curing adhesive preparations and antihomotoxic drug “Traumeel”, the application of which was substantiated by experimental studies in laboratory animals. The purpose of the study was to confirm clinically the experimentally obtained results to protect the receptor apparatus of the teeth by using the antihomotoxic drug combined with the domestic light-curing adhesive. Materials and methods. The method was tested in 72 patients, of whom 57 were the main group and 15 were controls. They were divided into 3 subgroups by age. A total of 200 teeth were prepared for one-piece cast fixed implant-supported prostheses. Electro-odontometry (EO) was performed and masticatory force (MF) was measured by the proposed method (patent number 99095142 dated September 16, 1999) before the preparation, when an anesthetic was worn off and one month after preparation. Results. The positive results of our method were clinically confirmed by the EO data analysis and the MF values measured by proposed by us method on the day of the study, the next day, in a month after the intact teeth were coated with the proposed complex of preparations. When assessing the data obtained, it was found that there were no significant changes in the EO indices as well as MF indicators on the day of the examination, the next day, in a month after the examination in the study group compared with the control. Conclusions. Analyzing the results obtained, it can be noted that our method has a significant advantage in protecting the stumps during teeth preparation at the stages of treatment with non-removable prosthesis design and contributes to preventing complications of the hard dental tissue preparation.
format Article
id doaj-art-e4331627a93641409b586a2db29524aa
institution Kabale University
issn 2306-4145
2310-1210
language English
publishDate 2019-12-01
publisher Zaporizhzhia State Medical and Pharmaceutical University
record_format Article
series Zaporožskij Medicinskij Žurnal
spelling doaj-art-e4331627a93641409b586a2db29524aa2025-08-20T03:25:11ZengZaporizhzhia State Medical and Pharmaceutical UniversityZaporožskij Medicinskij Žurnal2306-41452310-12102019-12-0121679079410.14739/2310-1210.2019.6.186596Clinical study of a method for the receptor apparatus of the teeth protection at the stages of treatment with non-removable prosthesis designsO. V. VoznyiI. V. YanishenI. L. DiudinaV. H. TomilinA. V. PohorilaThis article presents the results of clinical approbation of our proposed method for protecting the receptor apparatus of the teeth through a complex of domestic light-curing adhesive preparations and antihomotoxic drug “Traumeel”, the application of which was substantiated by experimental studies in laboratory animals. The purpose of the study was to confirm clinically the experimentally obtained results to protect the receptor apparatus of the teeth by using the antihomotoxic drug combined with the domestic light-curing adhesive. Materials and methods. The method was tested in 72 patients, of whom 57 were the main group and 15 were controls. They were divided into 3 subgroups by age. A total of 200 teeth were prepared for one-piece cast fixed implant-supported prostheses. Electro-odontometry (EO) was performed and masticatory force (MF) was measured by the proposed method (patent number 99095142 dated September 16, 1999) before the preparation, when an anesthetic was worn off and one month after preparation. Results. The positive results of our method were clinically confirmed by the EO data analysis and the MF values measured by proposed by us method on the day of the study, the next day, in a month after the intact teeth were coated with the proposed complex of preparations. When assessing the data obtained, it was found that there were no significant changes in the EO indices as well as MF indicators on the day of the examination, the next day, in a month after the examination in the study group compared with the control. Conclusions. Analyzing the results obtained, it can be noted that our method has a significant advantage in protecting the stumps during teeth preparation at the stages of treatment with non-removable prosthesis design and contributes to preventing complications of the hard dental tissue preparation.http://zmj.zsmu.edu.ua/article/view/186596/187019receptor apparatusintact teethelectro-odontometrymasticationprotection techniquelight-curing adhesiveantihomotoxic drug
spellingShingle O. V. Voznyi
I. V. Yanishen
I. L. Diudina
V. H. Tomilin
A. V. Pohorila
Clinical study of a method for the receptor apparatus of the teeth protection at the stages of treatment with non-removable prosthesis designs
Zaporožskij Medicinskij Žurnal
receptor apparatus
intact teeth
electro-odontometry
mastication
protection technique
light-curing adhesive
antihomotoxic drug
title Clinical study of a method for the receptor apparatus of the teeth protection at the stages of treatment with non-removable prosthesis designs
title_full Clinical study of a method for the receptor apparatus of the teeth protection at the stages of treatment with non-removable prosthesis designs
title_fullStr Clinical study of a method for the receptor apparatus of the teeth protection at the stages of treatment with non-removable prosthesis designs
title_full_unstemmed Clinical study of a method for the receptor apparatus of the teeth protection at the stages of treatment with non-removable prosthesis designs
title_short Clinical study of a method for the receptor apparatus of the teeth protection at the stages of treatment with non-removable prosthesis designs
title_sort clinical study of a method for the receptor apparatus of the teeth protection at the stages of treatment with non removable prosthesis designs
topic receptor apparatus
intact teeth
electro-odontometry
mastication
protection technique
light-curing adhesive
antihomotoxic drug
url http://zmj.zsmu.edu.ua/article/view/186596/187019
work_keys_str_mv AT ovvoznyi clinicalstudyofamethodforthereceptorapparatusoftheteethprotectionatthestagesoftreatmentwithnonremovableprosthesisdesigns
AT ivyanishen clinicalstudyofamethodforthereceptorapparatusoftheteethprotectionatthestagesoftreatmentwithnonremovableprosthesisdesigns
AT ildiudina clinicalstudyofamethodforthereceptorapparatusoftheteethprotectionatthestagesoftreatmentwithnonremovableprosthesisdesigns
AT vhtomilin clinicalstudyofamethodforthereceptorapparatusoftheteethprotectionatthestagesoftreatmentwithnonremovableprosthesisdesigns
AT avpohorila clinicalstudyofamethodforthereceptorapparatusoftheteethprotectionatthestagesoftreatmentwithnonremovableprosthesisdesigns