Evaluation of Temperature Plume Distance under Effects of Groundwater Flow on Borehole Heat Exchanger
In the ground source heat pump (GSHP) system, the temperature around the borehole heat exchangers (BHEs) would continue to spread further with running time, in addition the groundwater flow would have an important impact on the thermal dispersion. Based on the heat transfer model considering groundw...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Journal of Refrigeration Magazines Agency Co., Ltd.
2014-01-01
|
| Series: | Zhileng xuebao |
| Subjects: | |
| Online Access: | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2014.03.026 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850071439792668672 |
|---|---|
| author | Mao Jinfeng Li Yong Zhang Hua Geng Shibin Han Xu |
| author_facet | Mao Jinfeng Li Yong Zhang Hua Geng Shibin Han Xu |
| author_sort | Mao Jinfeng |
| collection | DOAJ |
| description | In the ground source heat pump (GSHP) system, the temperature around the borehole heat exchangers (BHEs) would continue to spread further with running time, in addition the groundwater flow would have an important impact on the thermal dispersion. Based on the heat transfer model considering groundwater flow in aquifers, the approximate analytical expression of temperature plume distance was obtained, the factors including groundwater flow velocity,subsurface thermal conductivity and porosity affecting on the temperature plume distance were analyzed by comparing with infinite line source (ILS) model. The results from test platform showed that the temperature plume distance under the groundwater flow velocity was greatly larger than the distance under the pure conductive model and it was different along the axial direction of BHE. In the zone with the groundwater velocity larger than 1×10-6m/s, the distance of 8-10m between the boreholes was recommended for design along the groundwater flow direction. |
| format | Article |
| id | doaj-art-e3e63f2d03bb4408b6519262492e128b |
| institution | DOAJ |
| issn | 0253-4339 |
| language | zho |
| publishDate | 2014-01-01 |
| publisher | Journal of Refrigeration Magazines Agency Co., Ltd. |
| record_format | Article |
| series | Zhileng xuebao |
| spelling | doaj-art-e3e63f2d03bb4408b6519262492e128b2025-08-20T02:47:18ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392014-01-013566516480Evaluation of Temperature Plume Distance under Effects of Groundwater Flow on Borehole Heat ExchangerMao JinfengLi YongZhang HuaGeng ShibinHan XuIn the ground source heat pump (GSHP) system, the temperature around the borehole heat exchangers (BHEs) would continue to spread further with running time, in addition the groundwater flow would have an important impact on the thermal dispersion. Based on the heat transfer model considering groundwater flow in aquifers, the approximate analytical expression of temperature plume distance was obtained, the factors including groundwater flow velocity,subsurface thermal conductivity and porosity affecting on the temperature plume distance were analyzed by comparing with infinite line source (ILS) model. The results from test platform showed that the temperature plume distance under the groundwater flow velocity was greatly larger than the distance under the pure conductive model and it was different along the axial direction of BHE. In the zone with the groundwater velocity larger than 1×10-6m/s, the distance of 8-10m between the boreholes was recommended for design along the groundwater flow direction.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2014.03.026groundwater flowborehole exchangertemperature plume distance |
| spellingShingle | Mao Jinfeng Li Yong Zhang Hua Geng Shibin Han Xu Evaluation of Temperature Plume Distance under Effects of Groundwater Flow on Borehole Heat Exchanger Zhileng xuebao groundwater flow borehole exchanger temperature plume distance |
| title | Evaluation of Temperature Plume Distance under Effects of Groundwater Flow on Borehole Heat Exchanger |
| title_full | Evaluation of Temperature Plume Distance under Effects of Groundwater Flow on Borehole Heat Exchanger |
| title_fullStr | Evaluation of Temperature Plume Distance under Effects of Groundwater Flow on Borehole Heat Exchanger |
| title_full_unstemmed | Evaluation of Temperature Plume Distance under Effects of Groundwater Flow on Borehole Heat Exchanger |
| title_short | Evaluation of Temperature Plume Distance under Effects of Groundwater Flow on Borehole Heat Exchanger |
| title_sort | evaluation of temperature plume distance under effects of groundwater flow on borehole heat exchanger |
| topic | groundwater flow borehole exchanger temperature plume distance |
| url | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2014.03.026 |
| work_keys_str_mv | AT maojinfeng evaluationoftemperatureplumedistanceundereffectsofgroundwaterflowonboreholeheatexchanger AT liyong evaluationoftemperatureplumedistanceundereffectsofgroundwaterflowonboreholeheatexchanger AT zhanghua evaluationoftemperatureplumedistanceundereffectsofgroundwaterflowonboreholeheatexchanger AT gengshibin evaluationoftemperatureplumedistanceundereffectsofgroundwaterflowonboreholeheatexchanger AT hanxu evaluationoftemperatureplumedistanceundereffectsofgroundwaterflowonboreholeheatexchanger |