Research on control strategy for neutral-point balance in three-level configurations for railway energy dispatching equipment
Energy dispatching equipment (EDE) utilizes converters in an AC-DC-AC topology to perform energy management functions including negative sequence, harmonic suppression, reactive power compensation, and active energy dispatching transfer for railway traction power supply. However, the use of three-le...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Editorial Department of Electric Drive for Locomotives
2025-01-01
|
| Series: | 机车电传动 |
| Subjects: | |
| Online Access: | http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128X.2025.01.020 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850274126298611712 |
|---|---|
| author | CHEN Xin WANG Yue FU Gang QIU Lebing LIU Xiang XIANG Jinwen |
| author_facet | CHEN Xin WANG Yue FU Gang QIU Lebing LIU Xiang XIANG Jinwen |
| author_sort | CHEN Xin |
| collection | DOAJ |
| description | Energy dispatching equipment (EDE) utilizes converters in an AC-DC-AC topology to perform energy management functions including negative sequence, harmonic suppression, reactive power compensation, and active energy dispatching transfer for railway traction power supply. However, the use of three-level converters in EDE leads to neutral-point imbalance due to the inherent topological limitation. Additionally, the diverse energy management functions of EDE, combined with out-of-phase voltage on both ends of the converters, cause arbitrary fluctuations of the power factor on both ends of the converters, exacerbating the neutral-point voltage imbalance deficiency. This paper proposes a control method for neutral-point voltage balance in single-phase three-level AC-DC-AC converters, designed for neutral-point balance control applicable to full conditions with arbitrary power factors on both ends of the converter, which is suitable for EDE application scenarios. This method was validated and confirmed to be effective and feasible through simulations and high-voltage experiments. |
| format | Article |
| id | doaj-art-e3a3821e4dca49cc95f6ee3e27e89c26 |
| institution | OA Journals |
| issn | 1000-128X |
| language | zho |
| publishDate | 2025-01-01 |
| publisher | Editorial Department of Electric Drive for Locomotives |
| record_format | Article |
| series | 机车电传动 |
| spelling | doaj-art-e3a3821e4dca49cc95f6ee3e27e89c262025-08-20T01:51:13ZzhoEditorial Department of Electric Drive for Locomotives机车电传动1000-128X2025-01-0116217489786721Research on control strategy for neutral-point balance in three-level configurations for railway energy dispatching equipmentCHEN XinWANG YueFU GangQIU LebingLIU XiangXIANG JinwenEnergy dispatching equipment (EDE) utilizes converters in an AC-DC-AC topology to perform energy management functions including negative sequence, harmonic suppression, reactive power compensation, and active energy dispatching transfer for railway traction power supply. However, the use of three-level converters in EDE leads to neutral-point imbalance due to the inherent topological limitation. Additionally, the diverse energy management functions of EDE, combined with out-of-phase voltage on both ends of the converters, cause arbitrary fluctuations of the power factor on both ends of the converters, exacerbating the neutral-point voltage imbalance deficiency. This paper proposes a control method for neutral-point voltage balance in single-phase three-level AC-DC-AC converters, designed for neutral-point balance control applicable to full conditions with arbitrary power factors on both ends of the converter, which is suitable for EDE application scenarios. This method was validated and confirmed to be effective and feasible through simulations and high-voltage experiments.http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128X.2025.01.020railway energy dispatching equipmentsingle-phasethree-levelneutral-point voltage balance control |
| spellingShingle | CHEN Xin WANG Yue FU Gang QIU Lebing LIU Xiang XIANG Jinwen Research on control strategy for neutral-point balance in three-level configurations for railway energy dispatching equipment 机车电传动 railway energy dispatching equipment single-phase three-level neutral-point voltage balance control |
| title | Research on control strategy for neutral-point balance in three-level configurations for railway energy dispatching equipment |
| title_full | Research on control strategy for neutral-point balance in three-level configurations for railway energy dispatching equipment |
| title_fullStr | Research on control strategy for neutral-point balance in three-level configurations for railway energy dispatching equipment |
| title_full_unstemmed | Research on control strategy for neutral-point balance in three-level configurations for railway energy dispatching equipment |
| title_short | Research on control strategy for neutral-point balance in three-level configurations for railway energy dispatching equipment |
| title_sort | research on control strategy for neutral point balance in three level configurations for railway energy dispatching equipment |
| topic | railway energy dispatching equipment single-phase three-level neutral-point voltage balance control |
| url | http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128X.2025.01.020 |
| work_keys_str_mv | AT chenxin researchoncontrolstrategyforneutralpointbalanceinthreelevelconfigurationsforrailwayenergydispatchingequipment AT wangyue researchoncontrolstrategyforneutralpointbalanceinthreelevelconfigurationsforrailwayenergydispatchingequipment AT fugang researchoncontrolstrategyforneutralpointbalanceinthreelevelconfigurationsforrailwayenergydispatchingequipment AT qiulebing researchoncontrolstrategyforneutralpointbalanceinthreelevelconfigurationsforrailwayenergydispatchingequipment AT liuxiang researchoncontrolstrategyforneutralpointbalanceinthreelevelconfigurationsforrailwayenergydispatchingequipment AT xiangjinwen researchoncontrolstrategyforneutralpointbalanceinthreelevelconfigurationsforrailwayenergydispatchingequipment |