Ultrasound and CBCT analysis of blood flow and dimensions of the lingual vascular canal: A case control study
Objective: To assess the correlation between the diameter of the mandibular lingual vascular canal (MLVC) as determined on CBCT examination to blood flow and arterial diameter as determined by ultrasound Doppler analysis (USG) in dentate and edentulous patients. Methods: 20 subjects were equally dis...