Diagnostic System of Power Oil Transformer in Accordance with Thermal Parameters
The paper proposes a device and algorithms for early detection of slowly developing faults in a power transformer that cause its abnormal heating. The device differentiates from the others that it requires only temperature measurement of transformer tank surface and ambient temperatures. Experiment...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | Russian |
| Published: |
Belarusian National Technical University
2013-10-01
|
| Series: | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
| Online Access: | https://energy.bntu.by/jour/article/view/125 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849241670497861632 |
|---|---|
| author | D. I. Zalizny O. G. Shirokov |
| author_facet | D. I. Zalizny O. G. Shirokov |
| author_sort | D. I. Zalizny |
| collection | DOAJ |
| description | The paper proposes a device and algorithms for early detection of slowly developing faults in a power transformer that cause its abnormal heating. The device differentiates from the others that it requires only temperature measurement of transformer tank surface and ambient temperatures. Experimental 63 MV×A autotransformer tests have proved faithfulness of the developed algorithms. |
| format | Article |
| id | doaj-art-e29998371e754eaeaf2395e17e7052eb |
| institution | Kabale University |
| issn | 1029-7448 2414-0341 |
| language | Russian |
| publishDate | 2013-10-01 |
| publisher | Belarusian National Technical University |
| record_format | Article |
| series | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
| spelling | doaj-art-e29998371e754eaeaf2395e17e7052eb2025-08-20T04:00:06ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412013-10-01053037119Diagnostic System of Power Oil Transformer in Accordance with Thermal ParametersD. I. Zalizny0O. G. Shirokov1Pavel Sukhoi State Technical University of GomelPavel Sukhoi State Technical University of GomelThe paper proposes a device and algorithms for early detection of slowly developing faults in a power transformer that cause its abnormal heating. The device differentiates from the others that it requires only temperature measurement of transformer tank surface and ambient temperatures. Experimental 63 MV×A autotransformer tests have proved faithfulness of the developed algorithms.https://energy.bntu.by/jour/article/view/125 |
| spellingShingle | D. I. Zalizny O. G. Shirokov Diagnostic System of Power Oil Transformer in Accordance with Thermal Parameters Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
| title | Diagnostic System of Power Oil Transformer in Accordance with Thermal Parameters |
| title_full | Diagnostic System of Power Oil Transformer in Accordance with Thermal Parameters |
| title_fullStr | Diagnostic System of Power Oil Transformer in Accordance with Thermal Parameters |
| title_full_unstemmed | Diagnostic System of Power Oil Transformer in Accordance with Thermal Parameters |
| title_short | Diagnostic System of Power Oil Transformer in Accordance with Thermal Parameters |
| title_sort | diagnostic system of power oil transformer in accordance with thermal parameters |
| url | https://energy.bntu.by/jour/article/view/125 |
| work_keys_str_mv | AT dizalizny diagnosticsystemofpoweroiltransformerinaccordancewiththermalparameters AT ogshirokov diagnosticsystemofpoweroiltransformerinaccordancewiththermalparameters |