Novel Portable Device for Post Mortem Interval Estimation Using Vitreous Humor Analysis

<b>Background:</b> Accurately determining the post mortem interval (PMI) is critical in forensic investigations to reconstruct the sequence of events leading up to and following death. Traditional methods (e.g., observing livor mortis, rigor mortis, and using temperature-based models) ha...

Full description

Saved in:
Bibliographic Details
Main Authors: Louise Lijcklama à Nijeholt, Michael Fleermann, Micky Breukers, Jaap Knotter, Steven Staal, Brigitte Bruijns
Format: Article
Language:English
Published: MDPI AG 2025-04-01
Series:Forensic Sciences
Subjects:
Online Access:https://www.mdpi.com/2673-6756/5/2/18
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849432237709197312
author Louise Lijcklama à Nijeholt
Michael Fleermann
Micky Breukers
Jaap Knotter
Steven Staal
Brigitte Bruijns
author_facet Louise Lijcklama à Nijeholt
Michael Fleermann
Micky Breukers
Jaap Knotter
Steven Staal
Brigitte Bruijns
author_sort Louise Lijcklama à Nijeholt
collection DOAJ
description <b>Background:</b> Accurately determining the post mortem interval (PMI) is critical in forensic investigations to reconstruct the sequence of events leading up to and following death. Traditional methods (e.g., observing livor mortis, rigor mortis, and using temperature-based models) have limitations due to their empirical nature and susceptibility to environmental variables. The objective of this study was to assess the potential of a novel portable device, the Fisic Medimate™ system, for estimating PMI through the analysis of the potassium/sodium (K+/Na+) ratio in vitreous humor. <b>Method:</b> Vitreous humor samples were collected from pigs at various intervals up to 44.5 hours post-mortem. These samples were analyzed using the Fisic Medimate™ system to determine the K+/Na+ ratio. The analysis was conducted at different time points to establish a relationship between the K+/Na+ ratio and PMI. <b>Results:</b> The results indicated a log-linear relationship between the K+/Na+ ratio and PMI for periods up to 31 hours, with normal residuals. This relationship was observed across all samples, suggesting that the method provides reliable and consistent data. <b>Conclusions:</b> This method offers a rapid and portable solution for PMI determination, providing valuable data within minutes directly at the crime scene. While these findings suggest potential for on-site forensic applications, further validation under real-world conditions is required to confirm its broader applicability.
format Article
id doaj-art-e1d7cd62d0614da183148e6fb31ebb3a
institution Kabale University
issn 2673-6756
language English
publishDate 2025-04-01
publisher MDPI AG
record_format Article
series Forensic Sciences
spelling doaj-art-e1d7cd62d0614da183148e6fb31ebb3a2025-08-20T03:27:25ZengMDPI AGForensic Sciences2673-67562025-04-01521810.3390/forensicsci5020018Novel Portable Device for Post Mortem Interval Estimation Using Vitreous Humor AnalysisLouise Lijcklama à Nijeholt0Michael Fleermann1Micky Breukers2Jaap Knotter3Steven Staal4Brigitte Bruijns5Technologies for Criminal Investigations, Saxion University of Applied Sciences, M.H. Tromplaan 28, 7513 AB Enschede, The NetherlandsFaculty Life Science Engineering and Design (LED), Saxion University of Applied Sciences, M.H. Tromplaan 28, 7513 AB Enschede, The NetherlandsFaculty Life Science Engineering and Design (LED), Saxion University of Applied Sciences, M.H. Tromplaan 28, 7513 AB Enschede, The NetherlandsTechnologies for Criminal Investigations, Saxion University of Applied Sciences, M.H. Tromplaan 28, 7513 AB Enschede, The NetherlandsFisic BV, High Tech Factory, De Veldmaat 17, 7522 NM Enschede, The NetherlandsTechnologies for Criminal Investigations, Saxion University of Applied Sciences, M.H. Tromplaan 28, 7513 AB Enschede, The Netherlands<b>Background:</b> Accurately determining the post mortem interval (PMI) is critical in forensic investigations to reconstruct the sequence of events leading up to and following death. Traditional methods (e.g., observing livor mortis, rigor mortis, and using temperature-based models) have limitations due to their empirical nature and susceptibility to environmental variables. The objective of this study was to assess the potential of a novel portable device, the Fisic Medimate™ system, for estimating PMI through the analysis of the potassium/sodium (K+/Na+) ratio in vitreous humor. <b>Method:</b> Vitreous humor samples were collected from pigs at various intervals up to 44.5 hours post-mortem. These samples were analyzed using the Fisic Medimate™ system to determine the K+/Na+ ratio. The analysis was conducted at different time points to establish a relationship between the K+/Na+ ratio and PMI. <b>Results:</b> The results indicated a log-linear relationship between the K+/Na+ ratio and PMI for periods up to 31 hours, with normal residuals. This relationship was observed across all samples, suggesting that the method provides reliable and consistent data. <b>Conclusions:</b> This method offers a rapid and portable solution for PMI determination, providing valuable data within minutes directly at the crime scene. While these findings suggest potential for on-site forensic applications, further validation under real-world conditions is required to confirm its broader applicability.https://www.mdpi.com/2673-6756/5/2/18post mortem intervalforensic investigationvitreous humorpotassium/sodium ratioportable devicelog-linear relationship
spellingShingle Louise Lijcklama à Nijeholt
Michael Fleermann
Micky Breukers
Jaap Knotter
Steven Staal
Brigitte Bruijns
Novel Portable Device for Post Mortem Interval Estimation Using Vitreous Humor Analysis
Forensic Sciences
post mortem interval
forensic investigation
vitreous humor
potassium/sodium ratio
portable device
log-linear relationship
title Novel Portable Device for Post Mortem Interval Estimation Using Vitreous Humor Analysis
title_full Novel Portable Device for Post Mortem Interval Estimation Using Vitreous Humor Analysis
title_fullStr Novel Portable Device for Post Mortem Interval Estimation Using Vitreous Humor Analysis
title_full_unstemmed Novel Portable Device for Post Mortem Interval Estimation Using Vitreous Humor Analysis
title_short Novel Portable Device for Post Mortem Interval Estimation Using Vitreous Humor Analysis
title_sort novel portable device for post mortem interval estimation using vitreous humor analysis
topic post mortem interval
forensic investigation
vitreous humor
potassium/sodium ratio
portable device
log-linear relationship
url https://www.mdpi.com/2673-6756/5/2/18
work_keys_str_mv AT louiselijcklamaanijeholt novelportabledeviceforpostmortemintervalestimationusingvitreoushumoranalysis
AT michaelfleermann novelportabledeviceforpostmortemintervalestimationusingvitreoushumoranalysis
AT mickybreukers novelportabledeviceforpostmortemintervalestimationusingvitreoushumoranalysis
AT jaapknotter novelportabledeviceforpostmortemintervalestimationusingvitreoushumoranalysis
AT stevenstaal novelportabledeviceforpostmortemintervalestimationusingvitreoushumoranalysis
AT brigittebruijns novelportabledeviceforpostmortemintervalestimationusingvitreoushumoranalysis