The continuous glucose monitoring system correlates poorly with the glucose infusion rate

Saved in:
Bibliographic Details
Main Authors: Aleksandra Buczyńska, Izabela Szymońska, Przemko Kwinta, Mateusz Jagła
Format: Article
Language:English
Published: Termedia Publishing House 2025-03-01
Series:Pediatria Polska
Subjects:
Online Access:https://www.termedia.pl/The-continuous-glucose-monitoring-system-correlates-poorly-with-the-glucose-infusion-rate,127,55698,1,1.html
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849322214697992192
author Aleksandra Buczyńska
Izabela Szymońska
Przemko Kwinta
Mateusz Jagła
author_facet Aleksandra Buczyńska
Izabela Szymońska
Przemko Kwinta
Mateusz Jagła
author_sort Aleksandra Buczyńska
collection DOAJ
format Article
id doaj-art-e1633ee10e24465192d97bc1d72bf8d1
institution Kabale University
issn 0031-3939
2300-8660
language English
publishDate 2025-03-01
publisher Termedia Publishing House
record_format Article
series Pediatria Polska
spelling doaj-art-e1633ee10e24465192d97bc1d72bf8d12025-08-20T03:49:28ZengTermedia Publishing HousePediatria Polska0031-39392300-86602025-03-011001232810.5114/polp.2025.14819255698The continuous glucose monitoring system correlates poorly with the glucose infusion rateAleksandra BuczyńskaIzabela SzymońskaPrzemko KwintaMateusz Jagłahttps://www.termedia.pl/The-continuous-glucose-monitoring-system-correlates-poorly-with-the-glucose-infusion-rate,127,55698,1,1.htmlprematurity hyperglycaemia continuous glucose monitoring very low birth weight infants interstitial glucose concentration
spellingShingle Aleksandra Buczyńska
Izabela Szymońska
Przemko Kwinta
Mateusz Jagła
The continuous glucose monitoring system correlates poorly with the glucose infusion rate
Pediatria Polska
prematurity
hyperglycaemia
continuous glucose monitoring
very low birth weight infants
interstitial glucose concentration
title The continuous glucose monitoring system correlates poorly with the glucose infusion rate
title_full The continuous glucose monitoring system correlates poorly with the glucose infusion rate
title_fullStr The continuous glucose monitoring system correlates poorly with the glucose infusion rate
title_full_unstemmed The continuous glucose monitoring system correlates poorly with the glucose infusion rate
title_short The continuous glucose monitoring system correlates poorly with the glucose infusion rate
title_sort the continuous glucose monitoring system correlates poorly with the glucose infusion rate
topic prematurity
hyperglycaemia
continuous glucose monitoring
very low birth weight infants
interstitial glucose concentration
url https://www.termedia.pl/The-continuous-glucose-monitoring-system-correlates-poorly-with-the-glucose-infusion-rate,127,55698,1,1.html
work_keys_str_mv AT aleksandrabuczynska thecontinuousglucosemonitoringsystemcorrelatespoorlywiththeglucoseinfusionrate
AT izabelaszymonska thecontinuousglucosemonitoringsystemcorrelatespoorlywiththeglucoseinfusionrate
AT przemkokwinta thecontinuousglucosemonitoringsystemcorrelatespoorlywiththeglucoseinfusionrate
AT mateuszjagła thecontinuousglucosemonitoringsystemcorrelatespoorlywiththeglucoseinfusionrate