Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography.

<h4>Background</h4>To investigate the feasibility of a low tube voltage (80 kVp) protocol with low concentration contrast media (CM) (iodixanol 320 mgl/ml) as compared with a high tube voltage (100 kVp) protocol with high concentration CM (iomeprol 400 mgl/ml) in coronary CT angiography...

Full description

Saved in:
Bibliographic Details
Main Authors: Min Jae Cha, Sung Mok Kim, Tae Ran Ahn, Yeon Hyeon Choe
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2020-01-01
Series:PLoS ONE
Online Access:https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0236108&type=printable
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850043428011769856
author Min Jae Cha
Sung Mok Kim
Tae Ran Ahn
Yeon Hyeon Choe
author_facet Min Jae Cha
Sung Mok Kim
Tae Ran Ahn
Yeon Hyeon Choe
author_sort Min Jae Cha
collection DOAJ
description <h4>Background</h4>To investigate the feasibility of a low tube voltage (80 kVp) protocol with low concentration contrast media (CM) (iodixanol 320 mgl/ml) as compared with a high tube voltage (100 kVp) protocol with high concentration CM (iomeprol 400 mgl/ml) in coronary CT angiography (CCTA) for patients with body mass index less than 30.<h4>Materials and methods</h4>A total of 93 patients were randomly assigned into three groups and underwent CCTA as follows: Group A) 100 kVp, 100-350 mAs, 400 mgl/ml CM at 4ml/s, and reconstructed with filtered back projection; Group B and C) 80 kVp, 100-450 mAs, 320 mgl/ml CM at 4 ml/s and 5 ml/s, respectively and reconstructed with iterative reconstruction. Objective and subjective image quality (IQ) was analyzed.<h4>Results</h4>The image noise, intravascular attenuation, signal-to-noise ratio and contrast-to-noise ratio of major coronary arteries did not differ significantly among three groups. Subjective IQ analyses on vascular attenuation and image noise did not differ significantly, either (all of p > 0.05). Qualitative IQ of Group B and C was non-inferior to that of Group A. Substantial reduction of radiation exposure was achieved in group B (2.60 ± 0.48 mSv) and C (2.72 ± 0.54 mSv), compared with group A (3.58 ± 0.67 mSv) (p < 0.05).<h4>Conclusion</h4>CCTA at 80 kVp with 320 mgl/ml CM and iterative reconstruction is feasible, achieving radiation dose reduction, while preserving IQ.
format Article
id doaj-art-e155fb85fe184f589f87f67471306f51
institution DOAJ
issn 1932-6203
language English
publishDate 2020-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj-art-e155fb85fe184f589f87f67471306f512025-08-20T02:55:14ZengPublic Library of Science (PLoS)PLoS ONE1932-62032020-01-01157e023610810.1371/journal.pone.0236108Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography.Min Jae ChaSung Mok KimTae Ran AhnYeon Hyeon Choe<h4>Background</h4>To investigate the feasibility of a low tube voltage (80 kVp) protocol with low concentration contrast media (CM) (iodixanol 320 mgl/ml) as compared with a high tube voltage (100 kVp) protocol with high concentration CM (iomeprol 400 mgl/ml) in coronary CT angiography (CCTA) for patients with body mass index less than 30.<h4>Materials and methods</h4>A total of 93 patients were randomly assigned into three groups and underwent CCTA as follows: Group A) 100 kVp, 100-350 mAs, 400 mgl/ml CM at 4ml/s, and reconstructed with filtered back projection; Group B and C) 80 kVp, 100-450 mAs, 320 mgl/ml CM at 4 ml/s and 5 ml/s, respectively and reconstructed with iterative reconstruction. Objective and subjective image quality (IQ) was analyzed.<h4>Results</h4>The image noise, intravascular attenuation, signal-to-noise ratio and contrast-to-noise ratio of major coronary arteries did not differ significantly among three groups. Subjective IQ analyses on vascular attenuation and image noise did not differ significantly, either (all of p > 0.05). Qualitative IQ of Group B and C was non-inferior to that of Group A. Substantial reduction of radiation exposure was achieved in group B (2.60 ± 0.48 mSv) and C (2.72 ± 0.54 mSv), compared with group A (3.58 ± 0.67 mSv) (p < 0.05).<h4>Conclusion</h4>CCTA at 80 kVp with 320 mgl/ml CM and iterative reconstruction is feasible, achieving radiation dose reduction, while preserving IQ.https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0236108&type=printable
spellingShingle Min Jae Cha
Sung Mok Kim
Tae Ran Ahn
Yeon Hyeon Choe
Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography.
PLoS ONE
title Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography.
title_full Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography.
title_fullStr Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography.
title_full_unstemmed Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography.
title_short Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography.
title_sort comparing feasibility of low tube voltage protocol with low iodine concentration contrast and high tube voltage protocol with high iodine concentration contrast in coronary computed tomography angiography
url https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0236108&type=printable
work_keys_str_mv AT minjaecha comparingfeasibilityoflowtubevoltageprotocolwithlowiodineconcentrationcontrastandhightubevoltageprotocolwithhighiodineconcentrationcontrastincoronarycomputedtomographyangiography
AT sungmokkim comparingfeasibilityoflowtubevoltageprotocolwithlowiodineconcentrationcontrastandhightubevoltageprotocolwithhighiodineconcentrationcontrastincoronarycomputedtomographyangiography
AT taeranahn comparingfeasibilityoflowtubevoltageprotocolwithlowiodineconcentrationcontrastandhightubevoltageprotocolwithhighiodineconcentrationcontrastincoronarycomputedtomographyangiography
AT yeonhyeonchoe comparingfeasibilityoflowtubevoltageprotocolwithlowiodineconcentrationcontrastandhightubevoltageprotocolwithhighiodineconcentrationcontrastincoronarycomputedtomographyangiography