Effects of different polishing systems on the surface roughness of two ceromers

Objective: This in vitro study evaluated the effects of three polishing systems on the surface roughness of two ceromers. Material and Methods: 96 specimens (8 mm in diameter and 2 mm thick) were prepared in a metal mold using two restorative materials: CERAMAGE (Shofu, Japan) and VMLC VITA (VITA Z...

Full description

Saved in:
Bibliographic Details
Main Authors: Iris Durães, Giulian Lennon Macêdo, Cristal Fernandez Carvalho, Viviane Maia Barreto Oliveira, Emilena Maria Castor Xisto Lima
Format: Article
Language:English
Published: Universidade Estadual Paulista 2016-07-01
Series:Brazilian Dental Science
Online Access:https://ojs.ict.unesp.br/index.php/cob/article/view/1241
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849228689342988288
author Iris Durães
Giulian Lennon Macêdo
Cristal Fernandez Carvalho
Viviane Maia Barreto Oliveira
Emilena Maria Castor Xisto Lima
author_facet Iris Durães
Giulian Lennon Macêdo
Cristal Fernandez Carvalho
Viviane Maia Barreto Oliveira
Emilena Maria Castor Xisto Lima
author_sort Iris Durães
collection DOAJ
description Objective: This in vitro study evaluated the effects of three polishing systems on the surface roughness of two ceromers. Material and Methods: 96 specimens (8 mm in diameter and 2 mm thick) were prepared in a metal mold using two restorative materials: CERAMAGE (Shofu, Japan) and VMLC VITA (VITA Zahnfabrik, Germany). The specimens were divided into 4 groups (n=12): G1: positive control, Mylar strip; G2: abrasive tips, Edenta system; G3: silicon tips, Enhance system; and G4: abrasive tips, Shofu system. The parameter evaluated was the average surface roughness (Ra) determined by using a profilometer SJ 301 (Mitutoyo, Japan), followed by photographic evaluation images through Scanning Electron Microscopy (SEM), with a 1000x magnification range. The data was subjected to statistical analysis for comparison between the groups (ANOVA, Tukey and Student T-tests), with a significance level of 5%. Results: there was a statistically significant difference between the silicone tip Enhance and the other groups for both ceromers with higher values of surface roughness. There was no statistically significant difference between the ceromers, except for the Shofu system, which showed lower values of surface roughness for Vita VMLC. Conclusion: Within the limitations of this study, it was concluded that the Edenta and Shofu abrasive tips are more effective in reducing the surface roughness of ceromers compared with the Enhance silicone tip. Keywords: Resins; Surface roughness; Dental polishing.
format Article
id doaj-art-e08a87edf69f4aada14c0e6137886678
institution Kabale University
issn 2178-6011
language English
publishDate 2016-07-01
publisher Universidade Estadual Paulista
record_format Article
series Brazilian Dental Science
spelling doaj-art-e08a87edf69f4aada14c0e61378866782025-08-22T18:13:07ZengUniversidade Estadual PaulistaBrazilian Dental Science2178-60112016-07-0119210.14295/bds.2016.v19i2.1241Effects of different polishing systems on the surface roughness of two ceromersIris Durães0Giulian Lennon Macêdo1Cristal Fernandez Carvalho2Viviane Maia Barreto Oliveira3Emilena Maria Castor Xisto Lima4Nucleus of Integrated Clinic at primary care – União Metropolitana de Educação e Cultura – UNIME – Lauro de Freitas – Bahia – Brazil.União Metropolitana de Educação e Cultura – UNIME – Lauro de Freitas – Bahia – Brazil.Nucleus of Integrated Clinic at primary care – União Metropolitana de Educação e Cultura – UNIME – Lauro de Freitas – Bahia – Brazil.Department of Clinical Dentistry – Faculdade de Odontologia – Universidade Federal da Bahia – FOUFBA – Salvador – Bahia – Brasil.Department of Clinical Dentistry – Faculdade de Odontologia – Universidade Federal da Bahia – FOUFBA – Salvador – Bahia – Brasil. Objective: This in vitro study evaluated the effects of three polishing systems on the surface roughness of two ceromers. Material and Methods: 96 specimens (8 mm in diameter and 2 mm thick) were prepared in a metal mold using two restorative materials: CERAMAGE (Shofu, Japan) and VMLC VITA (VITA Zahnfabrik, Germany). The specimens were divided into 4 groups (n=12): G1: positive control, Mylar strip; G2: abrasive tips, Edenta system; G3: silicon tips, Enhance system; and G4: abrasive tips, Shofu system. The parameter evaluated was the average surface roughness (Ra) determined by using a profilometer SJ 301 (Mitutoyo, Japan), followed by photographic evaluation images through Scanning Electron Microscopy (SEM), with a 1000x magnification range. The data was subjected to statistical analysis for comparison between the groups (ANOVA, Tukey and Student T-tests), with a significance level of 5%. Results: there was a statistically significant difference between the silicone tip Enhance and the other groups for both ceromers with higher values of surface roughness. There was no statistically significant difference between the ceromers, except for the Shofu system, which showed lower values of surface roughness for Vita VMLC. Conclusion: Within the limitations of this study, it was concluded that the Edenta and Shofu abrasive tips are more effective in reducing the surface roughness of ceromers compared with the Enhance silicone tip. Keywords: Resins; Surface roughness; Dental polishing. https://ojs.ict.unesp.br/index.php/cob/article/view/1241
spellingShingle Iris Durães
Giulian Lennon Macêdo
Cristal Fernandez Carvalho
Viviane Maia Barreto Oliveira
Emilena Maria Castor Xisto Lima
Effects of different polishing systems on the surface roughness of two ceromers
Brazilian Dental Science
title Effects of different polishing systems on the surface roughness of two ceromers
title_full Effects of different polishing systems on the surface roughness of two ceromers
title_fullStr Effects of different polishing systems on the surface roughness of two ceromers
title_full_unstemmed Effects of different polishing systems on the surface roughness of two ceromers
title_short Effects of different polishing systems on the surface roughness of two ceromers
title_sort effects of different polishing systems on the surface roughness of two ceromers
url https://ojs.ict.unesp.br/index.php/cob/article/view/1241
work_keys_str_mv AT irisduraes effectsofdifferentpolishingsystemsonthesurfaceroughnessoftwoceromers
AT giulianlennonmacedo effectsofdifferentpolishingsystemsonthesurfaceroughnessoftwoceromers
AT cristalfernandezcarvalho effectsofdifferentpolishingsystemsonthesurfaceroughnessoftwoceromers
AT vivianemaiabarretooliveira effectsofdifferentpolishingsystemsonthesurfaceroughnessoftwoceromers
AT emilenamariacastorxistolima effectsofdifferentpolishingsystemsonthesurfaceroughnessoftwoceromers