Research on the Effect of IIDG on Local Feeder Protection

Because of its outstanding performance in economic benefit and environmental benefit, the inverter interfaced distributed generation (IIDG) has been widely used in distribution network. The access of IIDG makes the distribution network a complex network of multi-power supply, the bidirectional power...

Full description

Saved in:
Bibliographic Details
Main Authors: Jingsong DENG, Yingmin WANG, Difei SUN, Chenling ZHENG, Hanting YAN, Xiaojing GAO
Format: Article
Language:English
Published: Editorial Department of Power Generation Technology 2021-02-01
Series:发电技术
Subjects:
Online Access:https://www.pgtjournal.com/EN/10.12096/j.2096-4528.pgt.19001
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850062595773431808
author Jingsong DENG
Yingmin WANG
Difei SUN
Chenling ZHENG
Hanting YAN
Xiaojing GAO
author_facet Jingsong DENG
Yingmin WANG
Difei SUN
Chenling ZHENG
Hanting YAN
Xiaojing GAO
author_sort Jingsong DENG
collection DOAJ
description Because of its outstanding performance in economic benefit and environmental benefit, the inverter interfaced distributed generation (IIDG) has been widely used in distribution network. The access of IIDG makes the distribution network a complex network of multi-power supply, the bidirectional power flow may lead to the degradation of feeder automation performance based on undirectional power flow, and it is imposssible to isolate faults in time. Aiming at two typical application on overhead lines feeder automation implementation pattern: voltage time type feeder automation and current differential type feeder automation, discussed its working principle, considering the working principle of IIDG, the influence of IIDG's penetration on fault isolation and non-faulty area recovery in each feeder automation mode was analyzed in detail. The solution to reduce the impact of IIDG was proposed and the simulation was verified.
format Article
id doaj-art-dfc0d8bcc0dd4d61b4e6290f4b6aa6c3
institution DOAJ
issn 2096-4528
language English
publishDate 2021-02-01
publisher Editorial Department of Power Generation Technology
record_format Article
series 发电技术
spelling doaj-art-dfc0d8bcc0dd4d61b4e6290f4b6aa6c32025-08-20T02:49:52ZengEditorial Department of Power Generation Technology发电技术2096-45282021-02-0142111512110.12096/j.2096-4528.pgt.19001fdjs-42-1-115Research on the Effect of IIDG on Local Feeder ProtectionJingsong DENG0Yingmin WANG1Difei SUN2Chenling ZHENG3Hanting YAN4Xiaojing GAO5Guangdong Power Grid Co., Ltd., Huizhou Power Bureau, Huizhou 516003, Guangdong Province, ChinaGuangdong Power Grid Co., Ltd., Huizhou Power Bureau, Huizhou 516003, Guangdong Province, ChinaGuangdong Power Grid Co., Ltd., Huizhou Power Bureau, Huizhou 516003, Guangdong Province, ChinaGuangzhou Power Electrical Technology Co. Ltd, Guangzhou 510640, Guangdong Province, ChinaGuangzhou Power Electrical Technology Co. Ltd, Guangzhou 510640, Guangdong Province, ChinaGuangzhou Power Electrical Technology Co. Ltd, Guangzhou 510640, Guangdong Province, ChinaBecause of its outstanding performance in economic benefit and environmental benefit, the inverter interfaced distributed generation (IIDG) has been widely used in distribution network. The access of IIDG makes the distribution network a complex network of multi-power supply, the bidirectional power flow may lead to the degradation of feeder automation performance based on undirectional power flow, and it is imposssible to isolate faults in time. Aiming at two typical application on overhead lines feeder automation implementation pattern: voltage time type feeder automation and current differential type feeder automation, discussed its working principle, considering the working principle of IIDG, the influence of IIDG's penetration on fault isolation and non-faulty area recovery in each feeder automation mode was analyzed in detail. The solution to reduce the impact of IIDG was proposed and the simulation was verified.https://www.pgtjournal.com/EN/10.12096/j.2096-4528.pgt.19001inverter interfaced distriuted generation (iidg)bidirectional power flowfeeder automationvolatage-time feeder automationcurrent-level differential feeder automation
spellingShingle Jingsong DENG
Yingmin WANG
Difei SUN
Chenling ZHENG
Hanting YAN
Xiaojing GAO
Research on the Effect of IIDG on Local Feeder Protection
发电技术
inverter interfaced distriuted generation (iidg)
bidirectional power flow
feeder automation
volatage-time feeder automation
current-level differential feeder automation
title Research on the Effect of IIDG on Local Feeder Protection
title_full Research on the Effect of IIDG on Local Feeder Protection
title_fullStr Research on the Effect of IIDG on Local Feeder Protection
title_full_unstemmed Research on the Effect of IIDG on Local Feeder Protection
title_short Research on the Effect of IIDG on Local Feeder Protection
title_sort research on the effect of iidg on local feeder protection
topic inverter interfaced distriuted generation (iidg)
bidirectional power flow
feeder automation
volatage-time feeder automation
current-level differential feeder automation
url https://www.pgtjournal.com/EN/10.12096/j.2096-4528.pgt.19001
work_keys_str_mv AT jingsongdeng researchontheeffectofiidgonlocalfeederprotection
AT yingminwang researchontheeffectofiidgonlocalfeederprotection
AT difeisun researchontheeffectofiidgonlocalfeederprotection
AT chenlingzheng researchontheeffectofiidgonlocalfeederprotection
AT hantingyan researchontheeffectofiidgonlocalfeederprotection
AT xiaojinggao researchontheeffectofiidgonlocalfeederprotection