Patient–specific hemodynamic modeling to optimize LVAD speed and right heart health
Background: Left ventricular assist device (LVAD) speed optimization and right heart failure post device implantation are major clinical challenges. Right heart catheterization (RHC)–guided speed titration studies are often performed to optimize LVAD settings, which are unknown and must be optimized...
Saved in:
Main Authors: | Mustafa M. Ahmed, Holly Grant, Jasmine Martinez, Joshua Thomas, Mohammad Al-Ani, Alex Parker, Juan Vilaro, Juan Aranda, Venkat Keshav Chivukula |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2025-02-01
|
Series: | JHLT Open |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2950133424001393 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Prevalence, risk factors, and prognostic implications of intraoperative bleeding during CF-LVAD implant
by: Ibrahim Mortada, MD, et al.
Published: (2025-02-01) -
Right heart reverse remodeling: “facta non verba”
by: Tommaso Recchioni, et al.
Published: (2025-03-01) -
Pulmonary artery catheter use in acute myocardial infarction‐cardiogenic shock
by: Saraschandra Vallabhajosyula, et al.
Published: (2020-06-01) -
The impact of insurance type on listing status and wait‐list mortality of patients with left ventricular assist devices as bridge to transplantation
by: Alexandros Briasoulis, et al.
Published: (2020-06-01) -
Brain atrophy in heart failure patients following left ventricular assist device implantation or heart transplantation
by: D.Alan Herbst, MD, et al.
Published: (2025-02-01)