Determining and Analyzing Factors Affecting Fire Safety Based on Fire Risk Assessment Method for Engineering and providing Control Solutions: A Case Study in a Hospital

Introduction: Fire safety in healthcare centers is crucial due to the limited evacuation capacity of the occupants and the necessity of not disrupting the operation in these centers. In this study, the fire risk of a public hospital was evaluated using the Fire Risk Assessment Method for Engineering...

Full description

Saved in:
Bibliographic Details
Main Authors: Samaneh Salari, Azar Soltani, Maedeh Nadim Qaziany, Ali Karimi
Format: Article
Language:fas
Published: Tehran University of Medical Sciences 2024-10-01
Series:بهداشت و ایمنی کار
Subjects:
Online Access:http://jhsw.tums.ac.ir/article-1-7041-en.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850283612249784320
author Samaneh Salari
Azar Soltani
Maedeh Nadim Qaziany
Ali Karimi
author_facet Samaneh Salari
Azar Soltani
Maedeh Nadim Qaziany
Ali Karimi
author_sort Samaneh Salari
collection DOAJ
description Introduction: Fire safety in healthcare centers is crucial due to the limited evacuation capacity of the occupants and the necessity of not disrupting the operation in these centers. In this study, the fire risk of a public hospital was evaluated using the Fire Risk Assessment Method for Engineering (FRAME). Additionally, the factors affecting fire safety in the hospital were analyzed quantitavely, and fire control strategies were presented.  Material and Methods: First, the fire risk assessment checklist was filled in all the hospital departments. Then, the values of the factors affecting fire safety were obtained. In the next step, the fire risk for the building, occupants and activities were estimated using Excel software-FRAME. Finally, control strategies and intervention measures were presented based on the value of these factors.  Results: In the hospital under study, 22% of the departments posed an undesirable fire risk to the building and its property. On the other hand, 90% of the departments had risk levels that were undesirable for the occupants. The results of the initial risk (R0) showed that a balance between potential fire risk and risk acceptance can be established by implementing manual fire extinguishing systems and automatic detectors in all departments.  Conclusion: ased on the condition of the hospital studied, a balance between potential fire risk level and risk acceptance level was not established. Therefore, there is a need for fire control measures, especially fire safety measures for the occupants. The results of this study can be useful for readers and experts in interpreting fire risk assessments and presenting detailed control measures based on the risk assessment and the value of the parameters.
format Article
id doaj-art-df7332865bc3410d8a56ea2faa64633f
institution OA Journals
issn 2251-807X
2383-2088
language fas
publishDate 2024-10-01
publisher Tehran University of Medical Sciences
record_format Article
series بهداشت و ایمنی کار
spelling doaj-art-df7332865bc3410d8a56ea2faa64633f2025-08-20T01:47:44ZfasTehran University of Medical Sciencesبهداشت و ایمنی کار2251-807X2383-20882024-10-01143647660Determining and Analyzing Factors Affecting Fire Safety Based on Fire Risk Assessment Method for Engineering and providing Control Solutions: A Case Study in a HospitalSamaneh Salari0Azar Soltani1Maedeh Nadim Qaziany2Ali Karimi3 Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran School of Public Health, Hamedan University of Medical Sciences, Hamedan, Iran Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran Introduction: Fire safety in healthcare centers is crucial due to the limited evacuation capacity of the occupants and the necessity of not disrupting the operation in these centers. In this study, the fire risk of a public hospital was evaluated using the Fire Risk Assessment Method for Engineering (FRAME). Additionally, the factors affecting fire safety in the hospital were analyzed quantitavely, and fire control strategies were presented.  Material and Methods: First, the fire risk assessment checklist was filled in all the hospital departments. Then, the values of the factors affecting fire safety were obtained. In the next step, the fire risk for the building, occupants and activities were estimated using Excel software-FRAME. Finally, control strategies and intervention measures were presented based on the value of these factors.  Results: In the hospital under study, 22% of the departments posed an undesirable fire risk to the building and its property. On the other hand, 90% of the departments had risk levels that were undesirable for the occupants. The results of the initial risk (R0) showed that a balance between potential fire risk and risk acceptance can be established by implementing manual fire extinguishing systems and automatic detectors in all departments.  Conclusion: ased on the condition of the hospital studied, a balance between potential fire risk level and risk acceptance level was not established. Therefore, there is a need for fire control measures, especially fire safety measures for the occupants. The results of this study can be useful for readers and experts in interpreting fire risk assessments and presenting detailed control measures based on the risk assessment and the value of the parameters.http://jhsw.tums.ac.ir/article-1-7041-en.pdffire riskhospitalfire controlrisk assessmentcontrol solutionsframe
spellingShingle Samaneh Salari
Azar Soltani
Maedeh Nadim Qaziany
Ali Karimi
Determining and Analyzing Factors Affecting Fire Safety Based on Fire Risk Assessment Method for Engineering and providing Control Solutions: A Case Study in a Hospital
بهداشت و ایمنی کار
fire risk
hospital
fire control
risk assessment
control solutions
frame
title Determining and Analyzing Factors Affecting Fire Safety Based on Fire Risk Assessment Method for Engineering and providing Control Solutions: A Case Study in a Hospital
title_full Determining and Analyzing Factors Affecting Fire Safety Based on Fire Risk Assessment Method for Engineering and providing Control Solutions: A Case Study in a Hospital
title_fullStr Determining and Analyzing Factors Affecting Fire Safety Based on Fire Risk Assessment Method for Engineering and providing Control Solutions: A Case Study in a Hospital
title_full_unstemmed Determining and Analyzing Factors Affecting Fire Safety Based on Fire Risk Assessment Method for Engineering and providing Control Solutions: A Case Study in a Hospital
title_short Determining and Analyzing Factors Affecting Fire Safety Based on Fire Risk Assessment Method for Engineering and providing Control Solutions: A Case Study in a Hospital
title_sort determining and analyzing factors affecting fire safety based on fire risk assessment method for engineering and providing control solutions a case study in a hospital
topic fire risk
hospital
fire control
risk assessment
control solutions
frame
url http://jhsw.tums.ac.ir/article-1-7041-en.pdf
work_keys_str_mv AT samanehsalari determiningandanalyzingfactorsaffectingfiresafetybasedonfireriskassessmentmethodforengineeringandprovidingcontrolsolutionsacasestudyinahospital
AT azarsoltani determiningandanalyzingfactorsaffectingfiresafetybasedonfireriskassessmentmethodforengineeringandprovidingcontrolsolutionsacasestudyinahospital
AT maedehnadimqaziany determiningandanalyzingfactorsaffectingfiresafetybasedonfireriskassessmentmethodforengineeringandprovidingcontrolsolutionsacasestudyinahospital
AT alikarimi determiningandanalyzingfactorsaffectingfiresafetybasedonfireriskassessmentmethodforengineeringandprovidingcontrolsolutionsacasestudyinahospital