Application of a phase loop system to analysis of a doppler signal in ultrasonic systems

This paper presents a way of applying a phase loop system to the measurement of the instantaneous frequency of a Doppler signal in ultrasonic systems. This system was used to verify experimentally the dependence proposed by ANGELSEN [1], connecting the instantaneous probability distribution of the s...

Full description

Saved in:
Bibliographic Details
Main Authors: Maciej PIECHOCKI, Michel XHAARD, Pierre PERONNEAU
Format: Article
Language:English
Published: Institute of Fundamental Technological Research Polish Academy of Sciences 2015-07-01
Series:Archives of Acoustics
Online Access:https://acoustics.ippt.pan.pl/index.php/aa/article/view/3163
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850104754391220224
author Maciej PIECHOCKI
Michel XHAARD
Pierre PERONNEAU
author_facet Maciej PIECHOCKI
Michel XHAARD
Pierre PERONNEAU
author_sort Maciej PIECHOCKI
collection DOAJ
description This paper presents a way of applying a phase loop system to the measurement of the instantaneous frequency of a Doppler signal in ultrasonic systems. This system was used to verify experimentally the dependence proposed by ANGELSEN [1], connecting the instantaneous probability distribution of the signal with its power spectrum. It presents measured results for two, laminar and turbulent, flows, and also an example of the operation of the phase loop system for a signal with a low signal to noise power ratio.
format Article
id doaj-art-df17c2ad217846ee83c2f74369063f01
institution DOAJ
issn 0137-5075
2300-262X
language English
publishDate 2015-07-01
publisher Institute of Fundamental Technological Research Polish Academy of Sciences
record_format Article
series Archives of Acoustics
spelling doaj-art-df17c2ad217846ee83c2f74369063f012025-08-20T02:39:15ZengInstitute of Fundamental Technological Research Polish Academy of SciencesArchives of Acoustics0137-50752300-262X2015-07-01103Application of a phase loop system to analysis of a doppler signal in ultrasonic systemsMaciej PIECHOCKI0Michel XHAARD1Pierre PERONNEAU2Institute of Fundamental Technological Research, Polish Academy of SciencesInstrumentation et Dynamique Cardiovasculaire INSERM U265, Hopital BroussaisInstrumentation et Dynamique Cardiovasculaire INSERM U265, Hopital BroussaisThis paper presents a way of applying a phase loop system to the measurement of the instantaneous frequency of a Doppler signal in ultrasonic systems. This system was used to verify experimentally the dependence proposed by ANGELSEN [1], connecting the instantaneous probability distribution of the signal with its power spectrum. It presents measured results for two, laminar and turbulent, flows, and also an example of the operation of the phase loop system for a signal with a low signal to noise power ratio.https://acoustics.ippt.pan.pl/index.php/aa/article/view/3163
spellingShingle Maciej PIECHOCKI
Michel XHAARD
Pierre PERONNEAU
Application of a phase loop system to analysis of a doppler signal in ultrasonic systems
Archives of Acoustics
title Application of a phase loop system to analysis of a doppler signal in ultrasonic systems
title_full Application of a phase loop system to analysis of a doppler signal in ultrasonic systems
title_fullStr Application of a phase loop system to analysis of a doppler signal in ultrasonic systems
title_full_unstemmed Application of a phase loop system to analysis of a doppler signal in ultrasonic systems
title_short Application of a phase loop system to analysis of a doppler signal in ultrasonic systems
title_sort application of a phase loop system to analysis of a doppler signal in ultrasonic systems
url https://acoustics.ippt.pan.pl/index.php/aa/article/view/3163
work_keys_str_mv AT maciejpiechocki applicationofaphaseloopsystemtoanalysisofadopplersignalinultrasonicsystems
AT michelxhaard applicationofaphaseloopsystemtoanalysisofadopplersignalinultrasonicsystems
AT pierreperonneau applicationofaphaseloopsystemtoanalysisofadopplersignalinultrasonicsystems