Determination of Flavanones in Orange Juices Obtained from Different Sources by HPLC/DAD

Flavanones (hesperidin, naringenin, naringin, and poncirin) in industrial, hand-squeezed orange juices and from fresh-in-squeeze machines orange juices were determined by HPLC/DAD analysis using a previously described liquid-liquid extraction method. Method validation including the accuracy was perf...

Full description

Saved in:
Bibliographic Details
Main Authors: Lidércia C. R. Cerqueira e Silva, Jorge M. David, Rafael dos S. Q. Borges, Sérgio L. C. Ferreira, Juceni P. David, Pedro S. dos Reis, Roy E. Bruns
Format: Article
Language:English
Published: Wiley 2014-01-01
Series:Journal of Analytical Methods in Chemistry
Online Access:http://dx.doi.org/10.1155/2014/296838
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832564641940635648
author Lidércia C. R. Cerqueira e Silva
Jorge M. David
Rafael dos S. Q. Borges
Sérgio L. C. Ferreira
Juceni P. David
Pedro S. dos Reis
Roy E. Bruns
author_facet Lidércia C. R. Cerqueira e Silva
Jorge M. David
Rafael dos S. Q. Borges
Sérgio L. C. Ferreira
Juceni P. David
Pedro S. dos Reis
Roy E. Bruns
author_sort Lidércia C. R. Cerqueira e Silva
collection DOAJ
description Flavanones (hesperidin, naringenin, naringin, and poncirin) in industrial, hand-squeezed orange juices and from fresh-in-squeeze machines orange juices were determined by HPLC/DAD analysis using a previously described liquid-liquid extraction method. Method validation including the accuracy was performed by using recovery tests. Samples (36) collected from different Brazilian locations and brands were analyzed. Concentrations were determined using an external standard curve. The limits of detection (LOD) and the limits of quantification (LOQ) calculated were 0.0037, 1.87, 0.0147, and 0.0066 mg 100 g−1 and 0.0089, 7.84, 0.0302, and 0.0200 mg 100 g−1 for naringin, hesperidin, poncirin, and naringenin, respectively. The results demonstrated that hesperidin was present at the highest concentration levels, especially in the industrial orange juices. Its average content and concentration range were 69.85 and 18.80–139.00 mg 100 g−1. The other flavanones showed the lowest concentration levels. The average contents and concentration ranges found were 0.019, 0.01–0.30, and 0.12 and 0.1–0.17, 0.13, and 0.01–0.36 mg 100 g−1, respectively. The results were also evaluated using the principal component analysis (PCA) multivariate analysis technique which showed that poncirin, naringenin, and naringin were the principal elements that contributed to the variability in the sample concentrations.
format Article
id doaj-art-def04fd402fe4fc4a293403c2bfa5e0d
institution Kabale University
issn 2090-8865
2090-8873
language English
publishDate 2014-01-01
publisher Wiley
record_format Article
series Journal of Analytical Methods in Chemistry
spelling doaj-art-def04fd402fe4fc4a293403c2bfa5e0d2025-02-03T01:10:38ZengWileyJournal of Analytical Methods in Chemistry2090-88652090-88732014-01-01201410.1155/2014/296838296838Determination of Flavanones in Orange Juices Obtained from Different Sources by HPLC/DADLidércia C. R. Cerqueira e Silva0Jorge M. David1Rafael dos S. Q. Borges2Sérgio L. C. Ferreira3Juceni P. David4Pedro S. dos Reis5Roy E. Bruns6Universidade Federal da Bahia, Instituto de Química, 40170-290 Salvador, BA, BrazilUniversidade Federal da Bahia, Instituto de Química, 40170-290 Salvador, BA, BrazilUniversidade Federal da Bahia, Instituto de Química, 40170-290 Salvador, BA, BrazilUniversidade Federal da Bahia, Instituto de Química, 40170-290 Salvador, BA, BrazilUniversidade Federal da Bahia, Faculdade de Farmácia, 40170-290 Salvador, BA, BrazilUniversidade Federal da Bahia, Instituto de Química, 40170-290 Salvador, BA, BrazilUniversidade Estadual de Campinas, Instituto de Química, 13084-971 Campinas, SP, BrazilFlavanones (hesperidin, naringenin, naringin, and poncirin) in industrial, hand-squeezed orange juices and from fresh-in-squeeze machines orange juices were determined by HPLC/DAD analysis using a previously described liquid-liquid extraction method. Method validation including the accuracy was performed by using recovery tests. Samples (36) collected from different Brazilian locations and brands were analyzed. Concentrations were determined using an external standard curve. The limits of detection (LOD) and the limits of quantification (LOQ) calculated were 0.0037, 1.87, 0.0147, and 0.0066 mg 100 g−1 and 0.0089, 7.84, 0.0302, and 0.0200 mg 100 g−1 for naringin, hesperidin, poncirin, and naringenin, respectively. The results demonstrated that hesperidin was present at the highest concentration levels, especially in the industrial orange juices. Its average content and concentration range were 69.85 and 18.80–139.00 mg 100 g−1. The other flavanones showed the lowest concentration levels. The average contents and concentration ranges found were 0.019, 0.01–0.30, and 0.12 and 0.1–0.17, 0.13, and 0.01–0.36 mg 100 g−1, respectively. The results were also evaluated using the principal component analysis (PCA) multivariate analysis technique which showed that poncirin, naringenin, and naringin were the principal elements that contributed to the variability in the sample concentrations.http://dx.doi.org/10.1155/2014/296838
spellingShingle Lidércia C. R. Cerqueira e Silva
Jorge M. David
Rafael dos S. Q. Borges
Sérgio L. C. Ferreira
Juceni P. David
Pedro S. dos Reis
Roy E. Bruns
Determination of Flavanones in Orange Juices Obtained from Different Sources by HPLC/DAD
Journal of Analytical Methods in Chemistry
title Determination of Flavanones in Orange Juices Obtained from Different Sources by HPLC/DAD
title_full Determination of Flavanones in Orange Juices Obtained from Different Sources by HPLC/DAD
title_fullStr Determination of Flavanones in Orange Juices Obtained from Different Sources by HPLC/DAD
title_full_unstemmed Determination of Flavanones in Orange Juices Obtained from Different Sources by HPLC/DAD
title_short Determination of Flavanones in Orange Juices Obtained from Different Sources by HPLC/DAD
title_sort determination of flavanones in orange juices obtained from different sources by hplc dad
url http://dx.doi.org/10.1155/2014/296838
work_keys_str_mv AT liderciacrcerqueiraesilva determinationofflavanonesinorangejuicesobtainedfromdifferentsourcesbyhplcdad
AT jorgemdavid determinationofflavanonesinorangejuicesobtainedfromdifferentsourcesbyhplcdad
AT rafaeldossqborges determinationofflavanonesinorangejuicesobtainedfromdifferentsourcesbyhplcdad
AT sergiolcferreira determinationofflavanonesinorangejuicesobtainedfromdifferentsourcesbyhplcdad
AT jucenipdavid determinationofflavanonesinorangejuicesobtainedfromdifferentsourcesbyhplcdad
AT pedrosdosreis determinationofflavanonesinorangejuicesobtainedfromdifferentsourcesbyhplcdad
AT royebruns determinationofflavanonesinorangejuicesobtainedfromdifferentsourcesbyhplcdad