Tibia Adamantinoma Resection and Reconstruction with a Custom-Made Total Tibia Endoprosthesis: A Case Report with 8-Year Follow-Up

This case study describes a total tibia resection and reconstruction with a custom-made endoprosthetic replacement (EPR) and a long-term, 8-year follow-up. The patient underwent a total tibia adamantinoma resection in 2009. Reconstruction was performed with a custom-made total tibia EPR, where both...

Full description

Saved in:
Bibliographic Details
Main Authors: Gilber Kask, Toni-Karri Pakarinen, Jyrki Parkkinen, Hannu Kuokkanen, Jyrki Nieminen, Minna K. Laitinen
Format: Article
Language:English
Published: Wiley 2018-01-01
Series:Case Reports in Orthopedics
Online Access:http://dx.doi.org/10.1155/2018/3656913
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832551011804250112
author Gilber Kask
Toni-Karri Pakarinen
Jyrki Parkkinen
Hannu Kuokkanen
Jyrki Nieminen
Minna K. Laitinen
author_facet Gilber Kask
Toni-Karri Pakarinen
Jyrki Parkkinen
Hannu Kuokkanen
Jyrki Nieminen
Minna K. Laitinen
author_sort Gilber Kask
collection DOAJ
description This case study describes a total tibia resection and reconstruction with a custom-made endoprosthetic replacement (EPR) and a long-term, 8-year follow-up. The patient underwent a total tibia adamantinoma resection in 2009. Reconstruction was performed with a custom-made total tibia EPR, where both the knee joint and ankle joint were reconstructed. Two muscle flaps, latissimus dorsi free flap and a pedicled medial gastrocnemius flap, were used for soft tissue reconstruction. The patient returned to normal life as a kindergarten teacher, without complications for eight years. This case demonstrated the importance of successful multidisciplinary teamwork in close collaboration with industry. In our best knowledge, no over 2 years of follow-up of total tibia replacement reports have been published.
format Article
id doaj-art-ded067859c1549168549b90a59ed5dc9
institution Kabale University
issn 2090-6749
2090-6757
language English
publishDate 2018-01-01
publisher Wiley
record_format Article
series Case Reports in Orthopedics
spelling doaj-art-ded067859c1549168549b90a59ed5dc92025-02-03T06:05:22ZengWileyCase Reports in Orthopedics2090-67492090-67572018-01-01201810.1155/2018/36569133656913Tibia Adamantinoma Resection and Reconstruction with a Custom-Made Total Tibia Endoprosthesis: A Case Report with 8-Year Follow-UpGilber Kask0Toni-Karri Pakarinen1Jyrki Parkkinen2Hannu Kuokkanen3Jyrki Nieminen4Minna K. Laitinen5Department of Orthopaedics and Traumatology, Unit of Musculoskeletal Surgery, Tampere University Hospital, Teiskontie 35, 33521 Tampere, FinlandDepartment of Orthopaedics and Traumatology, Unit of Musculoskeletal Surgery, Tampere University Hospital, Teiskontie 35, 33521 Tampere, FinlandFimlab Laboratories, Arvo Ylpön katu 4, 33520 Tampere, FinlandDivision of Plastic Surgery, Helsinki University Central Hospital, Topeliuksenkatu 5, 00260 Helsinki, FinlandCoxa Hospital for Joint Replacement, Biokatu 6, 33520 Tampere, FinlandDepartment of Orthopaedics and Traumatology, Unit of Musculoskeletal Surgery, Tampere University Hospital, Teiskontie 35, 33521 Tampere, FinlandThis case study describes a total tibia resection and reconstruction with a custom-made endoprosthetic replacement (EPR) and a long-term, 8-year follow-up. The patient underwent a total tibia adamantinoma resection in 2009. Reconstruction was performed with a custom-made total tibia EPR, where both the knee joint and ankle joint were reconstructed. Two muscle flaps, latissimus dorsi free flap and a pedicled medial gastrocnemius flap, were used for soft tissue reconstruction. The patient returned to normal life as a kindergarten teacher, without complications for eight years. This case demonstrated the importance of successful multidisciplinary teamwork in close collaboration with industry. In our best knowledge, no over 2 years of follow-up of total tibia replacement reports have been published.http://dx.doi.org/10.1155/2018/3656913
spellingShingle Gilber Kask
Toni-Karri Pakarinen
Jyrki Parkkinen
Hannu Kuokkanen
Jyrki Nieminen
Minna K. Laitinen
Tibia Adamantinoma Resection and Reconstruction with a Custom-Made Total Tibia Endoprosthesis: A Case Report with 8-Year Follow-Up
Case Reports in Orthopedics
title Tibia Adamantinoma Resection and Reconstruction with a Custom-Made Total Tibia Endoprosthesis: A Case Report with 8-Year Follow-Up
title_full Tibia Adamantinoma Resection and Reconstruction with a Custom-Made Total Tibia Endoprosthesis: A Case Report with 8-Year Follow-Up
title_fullStr Tibia Adamantinoma Resection and Reconstruction with a Custom-Made Total Tibia Endoprosthesis: A Case Report with 8-Year Follow-Up
title_full_unstemmed Tibia Adamantinoma Resection and Reconstruction with a Custom-Made Total Tibia Endoprosthesis: A Case Report with 8-Year Follow-Up
title_short Tibia Adamantinoma Resection and Reconstruction with a Custom-Made Total Tibia Endoprosthesis: A Case Report with 8-Year Follow-Up
title_sort tibia adamantinoma resection and reconstruction with a custom made total tibia endoprosthesis a case report with 8 year follow up
url http://dx.doi.org/10.1155/2018/3656913
work_keys_str_mv AT gilberkask tibiaadamantinomaresectionandreconstructionwithacustommadetotaltibiaendoprosthesisacasereportwith8yearfollowup
AT tonikarripakarinen tibiaadamantinomaresectionandreconstructionwithacustommadetotaltibiaendoprosthesisacasereportwith8yearfollowup
AT jyrkiparkkinen tibiaadamantinomaresectionandreconstructionwithacustommadetotaltibiaendoprosthesisacasereportwith8yearfollowup
AT hannukuokkanen tibiaadamantinomaresectionandreconstructionwithacustommadetotaltibiaendoprosthesisacasereportwith8yearfollowup
AT jyrkinieminen tibiaadamantinomaresectionandreconstructionwithacustommadetotaltibiaendoprosthesisacasereportwith8yearfollowup
AT minnaklaitinen tibiaadamantinomaresectionandreconstructionwithacustommadetotaltibiaendoprosthesisacasereportwith8yearfollowup