An Ecofriendly and Stability-Indicating HPLC Method for Determination of Permethrin Isomers: Application to Pharmaceutical Analysis
A green, simple, and stability-indicating RP-HPLC method was developed for simultaneous determination of permethrin isomers in pharmaceutical preparations. The separation was based on a C18 analytical column (150 × 4.6 mm, i.d., 5 μm). The mobile phase consisted of ethanol: phosphoric acid solution...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2013-01-01
|
Series: | Journal of Chemistry |
Online Access: | http://dx.doi.org/10.1155/2013/697831 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832562707736297472 |
---|---|
author | Minoo Afshar Niloufar Salkhordeh Mehdi Rajabi |
author_facet | Minoo Afshar Niloufar Salkhordeh Mehdi Rajabi |
author_sort | Minoo Afshar |
collection | DOAJ |
description | A green, simple, and stability-indicating RP-HPLC method was developed for simultaneous determination of permethrin isomers in pharmaceutical preparations. The separation was based on a C18 analytical column (150 × 4.6 mm, i.d., 5 μm). The mobile phase consisted of ethanol: phosphoric acid solution (pH = 3) (67 : 33, v/v). The elution was carried out at 30°C temperature with a flow rate of 1.0 mL/min. Quantitation was achieved with UV detection at 215 nm. In forced degradation studies, the drug was subjected to oxidation, hydrolysis, photolysis, and heat. The method was validated for specificity, linearity, precision, accuracy, and robustness. The applied procedure was found to be linear in permethrin concentration range of 0.5–50 μg/mL with correlation coefficients of 0.9996 for each isomer. Precision was evaluated by replicate analysis in which % relative standard deviation (RSD) values for areas were found below 2.0. The recoveries obtained (99.24%–100.72%) ensured the accuracy of the developed method. The peaks of permethrin isomers well resolved from various degradation products as well as the pharmaceutical excipients. Accordingly, the proposed validated and sustainable procedure was proved to be proper for routine analyzing and stability studies of permethrin in pharmaceutical preparations. |
format | Article |
id | doaj-art-de579e7f76bc425eaf4fd52366b4d107 |
institution | Kabale University |
issn | 2090-9063 2090-9071 |
language | English |
publishDate | 2013-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Chemistry |
spelling | doaj-art-de579e7f76bc425eaf4fd52366b4d1072025-02-03T01:22:02ZengWileyJournal of Chemistry2090-90632090-90712013-01-01201310.1155/2013/697831697831An Ecofriendly and Stability-Indicating HPLC Method for Determination of Permethrin Isomers: Application to Pharmaceutical AnalysisMinoo Afshar0Niloufar Salkhordeh1Mehdi Rajabi2Department of Pharmaceutics, Pharmaceutical Sciences Branch, Islamic Azad University (IAUPS), Tehran 193956466, IranDepartment of Pharmaceutics, Pharmaceutical Sciences Branch, Islamic Azad University (IAUPS), Tehran 193956466, IranDepartment of Clinical Pharmacy, Pharmaceutical Sciences Branch, Islamic Azad University (IAUPS), Tehran 193956466, IranA green, simple, and stability-indicating RP-HPLC method was developed for simultaneous determination of permethrin isomers in pharmaceutical preparations. The separation was based on a C18 analytical column (150 × 4.6 mm, i.d., 5 μm). The mobile phase consisted of ethanol: phosphoric acid solution (pH = 3) (67 : 33, v/v). The elution was carried out at 30°C temperature with a flow rate of 1.0 mL/min. Quantitation was achieved with UV detection at 215 nm. In forced degradation studies, the drug was subjected to oxidation, hydrolysis, photolysis, and heat. The method was validated for specificity, linearity, precision, accuracy, and robustness. The applied procedure was found to be linear in permethrin concentration range of 0.5–50 μg/mL with correlation coefficients of 0.9996 for each isomer. Precision was evaluated by replicate analysis in which % relative standard deviation (RSD) values for areas were found below 2.0. The recoveries obtained (99.24%–100.72%) ensured the accuracy of the developed method. The peaks of permethrin isomers well resolved from various degradation products as well as the pharmaceutical excipients. Accordingly, the proposed validated and sustainable procedure was proved to be proper for routine analyzing and stability studies of permethrin in pharmaceutical preparations.http://dx.doi.org/10.1155/2013/697831 |
spellingShingle | Minoo Afshar Niloufar Salkhordeh Mehdi Rajabi An Ecofriendly and Stability-Indicating HPLC Method for Determination of Permethrin Isomers: Application to Pharmaceutical Analysis Journal of Chemistry |
title | An Ecofriendly and Stability-Indicating HPLC Method for Determination of Permethrin Isomers: Application to Pharmaceutical Analysis |
title_full | An Ecofriendly and Stability-Indicating HPLC Method for Determination of Permethrin Isomers: Application to Pharmaceutical Analysis |
title_fullStr | An Ecofriendly and Stability-Indicating HPLC Method for Determination of Permethrin Isomers: Application to Pharmaceutical Analysis |
title_full_unstemmed | An Ecofriendly and Stability-Indicating HPLC Method for Determination of Permethrin Isomers: Application to Pharmaceutical Analysis |
title_short | An Ecofriendly and Stability-Indicating HPLC Method for Determination of Permethrin Isomers: Application to Pharmaceutical Analysis |
title_sort | ecofriendly and stability indicating hplc method for determination of permethrin isomers application to pharmaceutical analysis |
url | http://dx.doi.org/10.1155/2013/697831 |
work_keys_str_mv | AT minooafshar anecofriendlyandstabilityindicatinghplcmethodfordeterminationofpermethrinisomersapplicationtopharmaceuticalanalysis AT niloufarsalkhordeh anecofriendlyandstabilityindicatinghplcmethodfordeterminationofpermethrinisomersapplicationtopharmaceuticalanalysis AT mehdirajabi anecofriendlyandstabilityindicatinghplcmethodfordeterminationofpermethrinisomersapplicationtopharmaceuticalanalysis AT minooafshar ecofriendlyandstabilityindicatinghplcmethodfordeterminationofpermethrinisomersapplicationtopharmaceuticalanalysis AT niloufarsalkhordeh ecofriendlyandstabilityindicatinghplcmethodfordeterminationofpermethrinisomersapplicationtopharmaceuticalanalysis AT mehdirajabi ecofriendlyandstabilityindicatinghplcmethodfordeterminationofpermethrinisomersapplicationtopharmaceuticalanalysis |