HARMONIZING THREE-PHASE AC GRIDS A DUAL APPROACH COMPARISON OF PV-BATTERY ENERGY STORAGE SAPF CONTROLS
This paper investigates the effectiveness of two control approaches, Photovoltaic (PV)-Battery Energy Storage Systems (BESS) and SAPF, in harmonizing three-phase AC grids, focusing on power quality (PQ) and dq transformation theory. With the rising integration of renewable energy sources (RES), suc...
Saved in:
| Main Authors: | , , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Institute of Mechanics of Continua and Mathematical Sciences
2025-06-01
|
| Series: | Journal of Mechanics of Continua and Mathematical Sciences |
| Subjects: | |
| Online Access: | https://jmcms.s3.amazonaws.com/wp-content/uploads/2025/06/14192939/jmcms-2506029-Harmonizing-Three-Phase-AC-Grids-Bibhu.pdf |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849718916989845504 |
|---|---|
| author | Omkar Tripathy Sritam Parida Maheswar Prasad Behera Manoj Kumar Sahu E. Baby Anitha Maniraj Perumal Mohammad Arif Venkatesh Kumar C. |
| author_facet | Omkar Tripathy Sritam Parida Maheswar Prasad Behera Manoj Kumar Sahu E. Baby Anitha Maniraj Perumal Mohammad Arif Venkatesh Kumar C. |
| author_sort | Omkar Tripathy |
| collection | DOAJ |
| description | This paper investigates the effectiveness of two control approaches,
Photovoltaic (PV)-Battery Energy Storage Systems (BESS) and SAPF, in harmonizing three-phase AC grids, focusing on power quality (PQ) and dq transformation theory. With the rising integration of renewable energy sources (RES), such as PV systems, ensuring PQ becomes critical. The dual approach comparison aims to assess the performance and suitability of these control strategies. The PV-BESS system utilizes batteries to store excess PV-generated energy, offering grid flexibility and improving stability. Conversely, SAPF controls utilize power electronics to address harmonics and reactive power fluctuations, thereby enhancing grid reliability. Through simulation and analysis, this study evaluates the efficacy, cost-effectiveness, and practicality of both approaches in PQ improvement using dq theory. The findings contribute to advancing grid integration techniques, optimizing renewable energy utilization, and ensuring a robust and stable power supply infrastructure, guided by PQ and dq transformation theory principles. |
| format | Article |
| id | doaj-art-ddeabc3129d8492b91ce831478b86b48 |
| institution | DOAJ |
| issn | 0973-8975 2454-7190 |
| language | English |
| publishDate | 2025-06-01 |
| publisher | Institute of Mechanics of Continua and Mathematical Sciences |
| record_format | Article |
| series | Journal of Mechanics of Continua and Mathematical Sciences |
| spelling | doaj-art-ddeabc3129d8492b91ce831478b86b482025-08-20T03:12:15ZengInstitute of Mechanics of Continua and Mathematical SciencesJournal of Mechanics of Continua and Mathematical Sciences0973-89752454-71902025-06-01206285010.26782/jmcms.2025.06.00003HARMONIZING THREE-PHASE AC GRIDS A DUAL APPROACH COMPARISON OF PV-BATTERY ENERGY STORAGE SAPF CONTROLSOmkar Tripathy0Sritam Parida1Maheswar Prasad Behera2Manoj Kumar Sahu3E. Baby Anitha4Maniraj Perumal5Mohammad Arif6Venkatesh Kumar C.7Department of Electrical Engineering, IGIT, Sarang, BPUT, Rourkela, Odisha, India India.Department of Electrical Engineering, IGIT, Sarang, BPUT, Rourkela, Odisha, India India.Department of Electrical Engineering, IGIT, Sarang, BPUT, Rourkela, Odisha, India India.Department of Electrical Engineering, Centre for Advanced Post Graduate Studies, BPUT, Rourkela, Odisha, IndiaDepartment of CSE, K.S.R College of Engineering, Tiruchengode, Namakkal Dt., Tamil Nadu, India.Department of Electrical and Electronics Engineering, M. Kumarasamy College of Engineering, Thalavapalayam, Karur, Tamilnadu, India. Department of Computer Science and Engineering, Alliance University, Bengaluru, India.Department of Electrical and Electronics Engineering, St. Joseph's College of Engineering OMR Chennai, affiliated to Anna University, Chennai, India.This paper investigates the effectiveness of two control approaches, Photovoltaic (PV)-Battery Energy Storage Systems (BESS) and SAPF, in harmonizing three-phase AC grids, focusing on power quality (PQ) and dq transformation theory. With the rising integration of renewable energy sources (RES), such as PV systems, ensuring PQ becomes critical. The dual approach comparison aims to assess the performance and suitability of these control strategies. The PV-BESS system utilizes batteries to store excess PV-generated energy, offering grid flexibility and improving stability. Conversely, SAPF controls utilize power electronics to address harmonics and reactive power fluctuations, thereby enhancing grid reliability. Through simulation and analysis, this study evaluates the efficacy, cost-effectiveness, and practicality of both approaches in PQ improvement using dq theory. The findings contribute to advancing grid integration techniques, optimizing renewable energy utilization, and ensuring a robust and stable power supply infrastructure, guided by PQ and dq transformation theory principles.https://jmcms.s3.amazonaws.com/wp-content/uploads/2025/06/14192939/jmcms-2506029-Harmonizing-Three-Phase-AC-Grids-Bibhu.pdfpvbessshunt active power filters (sapf)power qualitypq and dq theory |
| spellingShingle | Omkar Tripathy Sritam Parida Maheswar Prasad Behera Manoj Kumar Sahu E. Baby Anitha Maniraj Perumal Mohammad Arif Venkatesh Kumar C. HARMONIZING THREE-PHASE AC GRIDS A DUAL APPROACH COMPARISON OF PV-BATTERY ENERGY STORAGE SAPF CONTROLS Journal of Mechanics of Continua and Mathematical Sciences pv bess shunt active power filters (sapf) power quality pq and dq theory |
| title | HARMONIZING THREE-PHASE AC GRIDS A DUAL APPROACH COMPARISON OF PV-BATTERY ENERGY STORAGE SAPF CONTROLS |
| title_full | HARMONIZING THREE-PHASE AC GRIDS A DUAL APPROACH COMPARISON OF PV-BATTERY ENERGY STORAGE SAPF CONTROLS |
| title_fullStr | HARMONIZING THREE-PHASE AC GRIDS A DUAL APPROACH COMPARISON OF PV-BATTERY ENERGY STORAGE SAPF CONTROLS |
| title_full_unstemmed | HARMONIZING THREE-PHASE AC GRIDS A DUAL APPROACH COMPARISON OF PV-BATTERY ENERGY STORAGE SAPF CONTROLS |
| title_short | HARMONIZING THREE-PHASE AC GRIDS A DUAL APPROACH COMPARISON OF PV-BATTERY ENERGY STORAGE SAPF CONTROLS |
| title_sort | harmonizing three phase ac grids a dual approach comparison of pv battery energy storage sapf controls |
| topic | pv bess shunt active power filters (sapf) power quality pq and dq theory |
| url | https://jmcms.s3.amazonaws.com/wp-content/uploads/2025/06/14192939/jmcms-2506029-Harmonizing-Three-Phase-AC-Grids-Bibhu.pdf |
| work_keys_str_mv | AT omkartripathy harmonizingthreephaseacgridsadualapproachcomparisonofpvbatteryenergystoragesapfcontrols AT sritamparida harmonizingthreephaseacgridsadualapproachcomparisonofpvbatteryenergystoragesapfcontrols AT maheswarprasadbehera harmonizingthreephaseacgridsadualapproachcomparisonofpvbatteryenergystoragesapfcontrols AT manojkumarsahu harmonizingthreephaseacgridsadualapproachcomparisonofpvbatteryenergystoragesapfcontrols AT ebabyanitha harmonizingthreephaseacgridsadualapproachcomparisonofpvbatteryenergystoragesapfcontrols AT manirajperumal harmonizingthreephaseacgridsadualapproachcomparisonofpvbatteryenergystoragesapfcontrols AT mohammadarif harmonizingthreephaseacgridsadualapproachcomparisonofpvbatteryenergystoragesapfcontrols AT venkateshkumarc harmonizingthreephaseacgridsadualapproachcomparisonofpvbatteryenergystoragesapfcontrols |