Comparison of accelerated strength testing methods as exemplified by 09G2S steel

One of the urgent tasks when establishing the endurance limits of steel is limiting the time of the experiment. The main purpose of this work is to compare several accelerated methods for determining the fatigue strength: the Locati method, the method of measuring electrical resistance and the calcu...

Full description

Saved in:
Bibliographic Details
Main Author: K. V. Kuskov
Format: Article
Language:English
Published: Samara National Research University 2025-06-01
Series:Вестник Самарского университета: Аэрокосмическая техника, технологии и машиностроение
Subjects:
Online Access:https://journals.ssau.ru/vestnik/article/viewFile/28702/11332
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849473288049262592
author K. V. Kuskov
author_facet K. V. Kuskov
author_sort K. V. Kuskov
collection DOAJ
description One of the urgent tasks when establishing the endurance limits of steel is limiting the time of the experiment. The main purpose of this work is to compare several accelerated methods for determining the fatigue strength: the Locati method, the method of measuring electrical resistance and the calculation method taking into account the microstructures of steel. The study was carried out on 09G2S steel in the as-delivered condition which has a ferrite-pearlite structure. As a result of the comparison, it was found that the Locati method and the method for determining the fatigue strength of low-carbon and low-alloy steels give almost identical results. The method of measuring electrical resistance gives the range of stresses in which the desired fatigue strength is located. It is shown that the first sharp jump in the change in electrical resistivity of the sample may indicate the beginning of the stage of cyclic microflow or the beginning of irreversible softening of the steel. In addition, the method of measuring electrical resistance can be useful in combination with the Locati method, when there is no data on the slope of the left branch of the fatigue curve; then using this method it is possible to determine the interval in which 3 samples need to be tested to construct this branch.
format Article
id doaj-art-dddc4d57c35545f9b02058834f26e825
institution Kabale University
issn 2542-0453
2541-7533
language English
publishDate 2025-06-01
publisher Samara National Research University
record_format Article
series Вестник Самарского университета: Аэрокосмическая техника, технологии и машиностроение
spelling doaj-art-dddc4d57c35545f9b02058834f26e8252025-08-20T03:24:11ZengSamara National Research UniversityВестник Самарского университета: Аэрокосмическая техника, технологии и машиностроение2542-04532541-75332025-06-0124215115810.18287/2541-7533-2025-24-2-151-1588970Comparison of accelerated strength testing methods as exemplified by 09G2S steelK. V. Kuskov0https://orcid.org/0000-0002-0698-8545Industrial University of TyumenOne of the urgent tasks when establishing the endurance limits of steel is limiting the time of the experiment. The main purpose of this work is to compare several accelerated methods for determining the fatigue strength: the Locati method, the method of measuring electrical resistance and the calculation method taking into account the microstructures of steel. The study was carried out on 09G2S steel in the as-delivered condition which has a ferrite-pearlite structure. As a result of the comparison, it was found that the Locati method and the method for determining the fatigue strength of low-carbon and low-alloy steels give almost identical results. The method of measuring electrical resistance gives the range of stresses in which the desired fatigue strength is located. It is shown that the first sharp jump in the change in electrical resistivity of the sample may indicate the beginning of the stage of cyclic microflow or the beginning of irreversible softening of the steel. In addition, the method of measuring electrical resistance can be useful in combination with the Locati method, when there is no data on the slope of the left branch of the fatigue curve; then using this method it is possible to determine the interval in which 3 samples need to be tested to construct this branch.https://journals.ssau.ru/vestnik/article/viewFile/28702/11332accelerated fatigue testingsteel 09g2slocati methodspecific electrical resistivity
spellingShingle K. V. Kuskov
Comparison of accelerated strength testing methods as exemplified by 09G2S steel
Вестник Самарского университета: Аэрокосмическая техника, технологии и машиностроение
accelerated fatigue testing
steel 09g2s
locati method
specific electrical resistivity
title Comparison of accelerated strength testing methods as exemplified by 09G2S steel
title_full Comparison of accelerated strength testing methods as exemplified by 09G2S steel
title_fullStr Comparison of accelerated strength testing methods as exemplified by 09G2S steel
title_full_unstemmed Comparison of accelerated strength testing methods as exemplified by 09G2S steel
title_short Comparison of accelerated strength testing methods as exemplified by 09G2S steel
title_sort comparison of accelerated strength testing methods as exemplified by 09g2s steel
topic accelerated fatigue testing
steel 09g2s
locati method
specific electrical resistivity
url https://journals.ssau.ru/vestnik/article/viewFile/28702/11332
work_keys_str_mv AT kvkuskov comparisonofacceleratedstrengthtestingmethodsasexemplifiedby09g2ssteel