Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS
This study is aimed at investigating a suitable method for rice sample preparation as well as validating and applying the method for monitoring the concentration of total arsenic, cadmium, and lead in rice by using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Various rice sample preparatio...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2016-01-01
|
Series: | Journal of Analytical Methods in Chemistry |
Online Access: | http://dx.doi.org/10.1155/2016/3968786 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832548496725508096 |
---|---|
author | Lidiane Raquel Verola Mataveli Márcia Liane Buzzo Luciana Juncioni de Arauz Maria de Fátima Henriques Carvalho Edna Emy Kumagai Arakaki Richard Matsuzaki Paulo Tiglea |
author_facet | Lidiane Raquel Verola Mataveli Márcia Liane Buzzo Luciana Juncioni de Arauz Maria de Fátima Henriques Carvalho Edna Emy Kumagai Arakaki Richard Matsuzaki Paulo Tiglea |
author_sort | Lidiane Raquel Verola Mataveli |
collection | DOAJ |
description | This study is aimed at investigating a suitable method for rice sample preparation as well as validating and applying the method for monitoring the concentration of total arsenic, cadmium, and lead in rice by using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Various rice sample preparation procedures were evaluated. The analytical method was validated by measuring several parameters including limit of detection (LOD), limit of quantification (LOQ), linearity, relative bias, and repeatability. Regarding the sample preparation, recoveries of spiked samples were within the acceptable range from 89.3 to 98.2% for muffle furnace, 94.2 to 103.3% for heating block, 81.0 to 115.0% for hot plate, and 92.8 to 108.2% for microwave. Validation parameters showed that the method fits for its purpose, being the total arsenic, cadmium, and lead within the Brazilian Legislation limits. The method was applied for analyzing 37 rice samples (including polished, brown, and parboiled), consumed by the Brazilian population. The total arsenic, cadmium, and lead contents were lower than the established legislative values, except for total arsenic in one brown rice sample. This study indicated the need to establish monitoring programs for emphasizing the study on this type of cereal, aiming at promoting the Public Health. |
format | Article |
id | doaj-art-dd2bf1e9024041829b235002c97eaec2 |
institution | Kabale University |
issn | 2090-8865 2090-8873 |
language | English |
publishDate | 2016-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Analytical Methods in Chemistry |
spelling | doaj-art-dd2bf1e9024041829b235002c97eaec22025-02-03T06:14:02ZengWileyJournal of Analytical Methods in Chemistry2090-88652090-88732016-01-01201610.1155/2016/39687863968786Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MSLidiane Raquel Verola Mataveli0Márcia Liane Buzzo1Luciana Juncioni de Arauz2Maria de Fátima Henriques Carvalho3Edna Emy Kumagai Arakaki4Richard Matsuzaki5Paulo Tiglea6Inorganic Contaminants Laboratory, Contaminants Center, Adolfo Lutz Institute, 355 Dr. Arnaldo Av., 01246-902 São Paulo, SP, BrazilInorganic Contaminants Laboratory, Contaminants Center, Adolfo Lutz Institute, 355 Dr. Arnaldo Av., 01246-902 São Paulo, SP, BrazilInorganic Contaminants Laboratory, Contaminants Center, Adolfo Lutz Institute, 355 Dr. Arnaldo Av., 01246-902 São Paulo, SP, BrazilInorganic Contaminants Laboratory, Contaminants Center, Adolfo Lutz Institute, 355 Dr. Arnaldo Av., 01246-902 São Paulo, SP, BrazilInorganic Contaminants Laboratory, Contaminants Center, Adolfo Lutz Institute, 355 Dr. Arnaldo Av., 01246-902 São Paulo, SP, BrazilInorganic Contaminants Laboratory, Contaminants Center, Adolfo Lutz Institute, 355 Dr. Arnaldo Av., 01246-902 São Paulo, SP, BrazilInorganic Contaminants Laboratory, Contaminants Center, Adolfo Lutz Institute, 355 Dr. Arnaldo Av., 01246-902 São Paulo, SP, BrazilThis study is aimed at investigating a suitable method for rice sample preparation as well as validating and applying the method for monitoring the concentration of total arsenic, cadmium, and lead in rice by using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Various rice sample preparation procedures were evaluated. The analytical method was validated by measuring several parameters including limit of detection (LOD), limit of quantification (LOQ), linearity, relative bias, and repeatability. Regarding the sample preparation, recoveries of spiked samples were within the acceptable range from 89.3 to 98.2% for muffle furnace, 94.2 to 103.3% for heating block, 81.0 to 115.0% for hot plate, and 92.8 to 108.2% for microwave. Validation parameters showed that the method fits for its purpose, being the total arsenic, cadmium, and lead within the Brazilian Legislation limits. The method was applied for analyzing 37 rice samples (including polished, brown, and parboiled), consumed by the Brazilian population. The total arsenic, cadmium, and lead contents were lower than the established legislative values, except for total arsenic in one brown rice sample. This study indicated the need to establish monitoring programs for emphasizing the study on this type of cereal, aiming at promoting the Public Health.http://dx.doi.org/10.1155/2016/3968786 |
spellingShingle | Lidiane Raquel Verola Mataveli Márcia Liane Buzzo Luciana Juncioni de Arauz Maria de Fátima Henriques Carvalho Edna Emy Kumagai Arakaki Richard Matsuzaki Paulo Tiglea Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS Journal of Analytical Methods in Chemistry |
title | Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS |
title_full | Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS |
title_fullStr | Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS |
title_full_unstemmed | Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS |
title_short | Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS |
title_sort | total arsenic cadmium and lead determination in brazilian rice samples using icp ms |
url | http://dx.doi.org/10.1155/2016/3968786 |
work_keys_str_mv | AT lidianeraquelverolamataveli totalarseniccadmiumandleaddeterminationinbrazilianricesamplesusingicpms AT marcialianebuzzo totalarseniccadmiumandleaddeterminationinbrazilianricesamplesusingicpms AT lucianajuncionidearauz totalarseniccadmiumandleaddeterminationinbrazilianricesamplesusingicpms AT mariadefatimahenriquescarvalho totalarseniccadmiumandleaddeterminationinbrazilianricesamplesusingicpms AT ednaemykumagaiarakaki totalarseniccadmiumandleaddeterminationinbrazilianricesamplesusingicpms AT richardmatsuzaki totalarseniccadmiumandleaddeterminationinbrazilianricesamplesusingicpms AT paulotiglea totalarseniccadmiumandleaddeterminationinbrazilianricesamplesusingicpms |