Twelve-pulse rectifiers in power supply system of urban electric transport aleva

The introduction of twelve-pulse rectifiers instead of six-pulse ones at traction substations of urban electric transport leads to an increase in technical and economic indicators, energy savings, a decrease in leakage current. These result in electrical safety of passengers, a trolleybus drive...

Full description

Saved in:
Bibliographic Details
Main Authors: E. Yu. Salita, T. V. Kovaleva
Format: Article
Language:English
Published: Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education 2023-02-01
Series:Омский научный вестник
Subjects:
Online Access:https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2023/%E2%84%961%20(185)%20(%D0%9E%D0%9D%D0%92)/71-75%20%D0%A1%D0%B0%D0%BB%D0%B8%D1%82%D0%B0%20%D0%95.%20%D0%AE.,%20%20%D0%9A%D0%BE%D0%B2%D0%B0%D0%BB%D0%B5%D0%B2%D0%B0%20%D0%A2.%20%D0%92..pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832544921683230720
author E. Yu. Salita
T. V. Kovaleva
author_facet E. Yu. Salita
T. V. Kovaleva
author_sort E. Yu. Salita
collection DOAJ
description The introduction of twelve-pulse rectifiers instead of six-pulse ones at traction substations of urban electric transport leads to an increase in technical and economic indicators, energy savings, a decrease in leakage current. These result in electrical safety of passengers, a trolleybus driver and depot maintenance personnel. Twelve-pulse rectifiers can have a serial or parallel connection of sixpulse bridges. With a parallel circuit, it is necessary to have an equalizing reactor. The implementation of a twelvepulse serial type rectification scheme can be carried out by industrial development by manufacturers of new dry converter transformers with different typical power and new rectifiers (blocks). As part of the new rectifiers, it is necessary to have tablet avalanche valves with coolers based on heat pipes due to their advantages over nonavalanche valves.
format Article
id doaj-art-dcd8ff710734468a83fef7bc45406959
institution Kabale University
issn 1813-8225
2541-7541
language English
publishDate 2023-02-01
publisher Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
record_format Article
series Омский научный вестник
spelling doaj-art-dcd8ff710734468a83fef7bc454069592025-02-03T09:03:39ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412023-02-011 (185)717510.25206/1813-8225-2023-185-71-75Twelve-pulse rectifiers in power supply system of urban electric transport alevaE. Yu. Salita0T. V. Kovaleva1Omsk State Transport UniversityOmsk State Transport UniversityThe introduction of twelve-pulse rectifiers instead of six-pulse ones at traction substations of urban electric transport leads to an increase in technical and economic indicators, energy savings, a decrease in leakage current. These result in electrical safety of passengers, a trolleybus driver and depot maintenance personnel. Twelve-pulse rectifiers can have a serial or parallel connection of sixpulse bridges. With a parallel circuit, it is necessary to have an equalizing reactor. The implementation of a twelvepulse serial type rectification scheme can be carried out by industrial development by manufacturers of new dry converter transformers with different typical power and new rectifiers (blocks). As part of the new rectifiers, it is necessary to have tablet avalanche valves with coolers based on heat pipes due to their advantages over nonavalanche valves.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2023/%E2%84%961%20(185)%20(%D0%9E%D0%9D%D0%92)/71-75%20%D0%A1%D0%B0%D0%BB%D0%B8%D1%82%D0%B0%20%D0%95.%20%D0%AE.,%20%20%D0%9A%D0%BE%D0%B2%D0%B0%D0%BB%D0%B5%D0%B2%D0%B0%20%D0%A2.%20%D0%92..pdfurban electric transporttraction substationtwelve-pulse rectifiertablet avalanche valvesleakage currenttechnical and economic indicators
spellingShingle E. Yu. Salita
T. V. Kovaleva
Twelve-pulse rectifiers in power supply system of urban electric transport aleva
Омский научный вестник
urban electric transport
traction substation
twelve-pulse rectifier
tablet avalanche valves
leakage current
technical and economic indicators
title Twelve-pulse rectifiers in power supply system of urban electric transport aleva
title_full Twelve-pulse rectifiers in power supply system of urban electric transport aleva
title_fullStr Twelve-pulse rectifiers in power supply system of urban electric transport aleva
title_full_unstemmed Twelve-pulse rectifiers in power supply system of urban electric transport aleva
title_short Twelve-pulse rectifiers in power supply system of urban electric transport aleva
title_sort twelve pulse rectifiers in power supply system of urban electric transport aleva
topic urban electric transport
traction substation
twelve-pulse rectifier
tablet avalanche valves
leakage current
technical and economic indicators
url https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2023/%E2%84%961%20(185)%20(%D0%9E%D0%9D%D0%92)/71-75%20%D0%A1%D0%B0%D0%BB%D0%B8%D1%82%D0%B0%20%D0%95.%20%D0%AE.,%20%20%D0%9A%D0%BE%D0%B2%D0%B0%D0%BB%D0%B5%D0%B2%D0%B0%20%D0%A2.%20%D0%92..pdf
work_keys_str_mv AT eyusalita twelvepulserectifiersinpowersupplysystemofurbanelectrictransportaleva
AT tvkovaleva twelvepulserectifiersinpowersupplysystemofurbanelectrictransportaleva