Rapid scan experiments using a conventional FT-ICR mass spectrometer

This paper reports results obtained with a home-made FT-ICR spectrometer when it is run in the rapid scan mode described by McIver. The ability of the technique for the measurements of wide range mass spectra has been demonstrated.

Saved in:
Bibliographic Details
Main Authors: G. Parisod, T. Gäumann
Format: Article
Language:deu
Published: Swiss Chemical Society 1980-06-01
Series:CHIMIA
Online Access:https://www.chimia.ch/chimia/article/view/9478
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849311011891314688
author G. Parisod
T. Gäumann
author_facet G. Parisod
T. Gäumann
author_sort G. Parisod
collection DOAJ
description This paper reports results obtained with a home-made FT-ICR spectrometer when it is run in the rapid scan mode described by McIver. The ability of the technique for the measurements of wide range mass spectra has been demonstrated.
format Article
id doaj-art-dbb118fdf54f4fc28b45ac3b25edced1
institution Kabale University
issn 0009-4293
2673-2424
language deu
publishDate 1980-06-01
publisher Swiss Chemical Society
record_format Article
series CHIMIA
spelling doaj-art-dbb118fdf54f4fc28b45ac3b25edced12025-08-20T03:53:33ZdeuSwiss Chemical SocietyCHIMIA0009-42932673-24241980-06-0134610.2533/chimia.1980.271Rapid scan experiments using a conventional FT-ICR mass spectrometerG. Parisod0T. Gäumann1Dept, of Physical Chemistry, Federal School of Technology, Lausanne, SwitzerlandDept, of Physical Chemistry, Federal School of Technology, Lausanne, Switzerland This paper reports results obtained with a home-made FT-ICR spectrometer when it is run in the rapid scan mode described by McIver. The ability of the technique for the measurements of wide range mass spectra has been demonstrated. https://www.chimia.ch/chimia/article/view/9478
spellingShingle G. Parisod
T. Gäumann
Rapid scan experiments using a conventional FT-ICR mass spectrometer
CHIMIA
title Rapid scan experiments using a conventional FT-ICR mass spectrometer
title_full Rapid scan experiments using a conventional FT-ICR mass spectrometer
title_fullStr Rapid scan experiments using a conventional FT-ICR mass spectrometer
title_full_unstemmed Rapid scan experiments using a conventional FT-ICR mass spectrometer
title_short Rapid scan experiments using a conventional FT-ICR mass spectrometer
title_sort rapid scan experiments using a conventional ft icr mass spectrometer
url https://www.chimia.ch/chimia/article/view/9478
work_keys_str_mv AT gparisod rapidscanexperimentsusingaconventionalfticrmassspectrometer
AT tgaumann rapidscanexperimentsusingaconventionalfticrmassspectrometer