Dynamic Variation Characteristics and Influential Factors of PM2.5 in Subway Platforms Under Air-conditioning Condition

This study investigated some of the major factors influencing subway PM pollutants under air-conditioning conditions through field measurements and CFD simulations on a Shanghai subway station. Based on the principle of the air-conditioning system, the particle concentrations at the air supply outle...

Full description

Saved in:
Bibliographic Details
Main Authors: Wang Lihui, Hu Tianwei, Zhang Jihua, Liu Jun, Zheng Yi, Song Jie, Pan Jun, Yang Jun, Fan Zier
Format: Article
Language:zho
Published: Journal of Refrigeration Magazines Agency Co., Ltd. 2019-01-01
Series:Zhileng xuebao
Subjects:
Online Access:http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2019.05.073
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849707831974952960
author Wang Lihui
Hu Tianwei
Zhang Jihua
Liu Jun
Zheng Yi
Song Jie
Pan Jun
Yang Jun
Fan Zier
author_facet Wang Lihui
Hu Tianwei
Zhang Jihua
Liu Jun
Zheng Yi
Song Jie
Pan Jun
Yang Jun
Fan Zier
author_sort Wang Lihui
collection DOAJ
description This study investigated some of the major factors influencing subway PM pollutants under air-conditioning conditions through field measurements and CFD simulations on a Shanghai subway station. Based on the principle of the air-conditioning system, the particle concentrations at the air supply outlet, return air outlet and the screen door creates a direct impact on particle concentration of the platform. Dust accumulation at the fresh air shaft is found to be a secondary dusting action when the fresh air is supplied, which leads to ahigher particle concentration in the subway station than that in outdoor air. Each factor’s influence on the platform particle concentration was analyzed through the orthogonal test. Results confirmed that the particle concentrations at air outlet and platform screen door, along with the supply air and return air velocity, significantly influenced theparticle concentration at platform; while the temperature ofsupplyair , platform screen door and the platform has little impacts on the particle concentration at platform.
format Article
id doaj-art-db06a56746f04cb0bd19578eb02b3f28
institution DOAJ
issn 0253-4339
language zho
publishDate 2019-01-01
publisher Journal of Refrigeration Magazines Agency Co., Ltd.
record_format Article
series Zhileng xuebao
spelling doaj-art-db06a56746f04cb0bd19578eb02b3f282025-08-20T03:15:50ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392019-01-014066508060Dynamic Variation Characteristics and Influential Factors of PM2.5 in Subway Platforms Under Air-conditioning ConditionWang LihuiHu TianweiZhang JihuaLiu JunZheng YiSong JiePan JunYang JunFan ZierThis study investigated some of the major factors influencing subway PM pollutants under air-conditioning conditions through field measurements and CFD simulations on a Shanghai subway station. Based on the principle of the air-conditioning system, the particle concentrations at the air supply outlet, return air outlet and the screen door creates a direct impact on particle concentration of the platform. Dust accumulation at the fresh air shaft is found to be a secondary dusting action when the fresh air is supplied, which leads to ahigher particle concentration in the subway station than that in outdoor air. Each factor’s influence on the platform particle concentration was analyzed through the orthogonal test. Results confirmed that the particle concentrations at air outlet and platform screen door, along with the supply air and return air velocity, significantly influenced theparticle concentration at platform; while the temperature ofsupplyair , platform screen door and the platform has little impacts on the particle concentration at platform.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2019.05.073subway platformair-conditioning systemthe screen doorPMorthogonal test
spellingShingle Wang Lihui
Hu Tianwei
Zhang Jihua
Liu Jun
Zheng Yi
Song Jie
Pan Jun
Yang Jun
Fan Zier
Dynamic Variation Characteristics and Influential Factors of PM2.5 in Subway Platforms Under Air-conditioning Condition
Zhileng xuebao
subway platform
air-conditioning system
the screen door
PM
orthogonal test
title Dynamic Variation Characteristics and Influential Factors of PM2.5 in Subway Platforms Under Air-conditioning Condition
title_full Dynamic Variation Characteristics and Influential Factors of PM2.5 in Subway Platforms Under Air-conditioning Condition
title_fullStr Dynamic Variation Characteristics and Influential Factors of PM2.5 in Subway Platforms Under Air-conditioning Condition
title_full_unstemmed Dynamic Variation Characteristics and Influential Factors of PM2.5 in Subway Platforms Under Air-conditioning Condition
title_short Dynamic Variation Characteristics and Influential Factors of PM2.5 in Subway Platforms Under Air-conditioning Condition
title_sort dynamic variation characteristics and influential factors of pm2 5 in subway platforms under air conditioning condition
topic subway platform
air-conditioning system
the screen door
PM
orthogonal test
url http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2019.05.073
work_keys_str_mv AT wanglihui dynamicvariationcharacteristicsandinfluentialfactorsofpm25insubwayplatformsunderairconditioningcondition
AT hutianwei dynamicvariationcharacteristicsandinfluentialfactorsofpm25insubwayplatformsunderairconditioningcondition
AT zhangjihua dynamicvariationcharacteristicsandinfluentialfactorsofpm25insubwayplatformsunderairconditioningcondition
AT liujun dynamicvariationcharacteristicsandinfluentialfactorsofpm25insubwayplatformsunderairconditioningcondition
AT zhengyi dynamicvariationcharacteristicsandinfluentialfactorsofpm25insubwayplatformsunderairconditioningcondition
AT songjie dynamicvariationcharacteristicsandinfluentialfactorsofpm25insubwayplatformsunderairconditioningcondition
AT panjun dynamicvariationcharacteristicsandinfluentialfactorsofpm25insubwayplatformsunderairconditioningcondition
AT yangjun dynamicvariationcharacteristicsandinfluentialfactorsofpm25insubwayplatformsunderairconditioningcondition
AT fanzier dynamicvariationcharacteristicsandinfluentialfactorsofpm25insubwayplatformsunderairconditioningcondition