Thermal Analysis of Direct Liquid-Immersed Solar Receiver for High Concentrating Photovoltaic System
Concentrator solar cells that operate at high solar concentration level must be cooled. In this paper, direct liquid immersion cooling of triple-junction solar cells (InGaP/InGaAs/Ge) is proposed as a heat dissipation solution for dense-array high concentrating photovoltaic (HCPV) systems. The advan...