A Sensitive UV Spectrophotometric Method for the Determination of Gabapentin

An accurate and validated spectrophotometric method was developed for the determination of gabapentin. This is simple, sensitive and low cost UV spectrophotometric method. The method is based on the direct measurement of the native absorbance of the drug. The detection was done at 210 nm. The method...

Full description

Saved in:
Bibliographic Details
Main Authors: R. Singh Gujral, S. Manirul Haque, P. Shanker
Format: Article
Language:English
Published: Wiley 2009-01-01
Series:E-Journal of Chemistry
Online Access:http://dx.doi.org/10.1155/2009/451967
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849472864008273920
author R. Singh Gujral
S. Manirul Haque
P. Shanker
author_facet R. Singh Gujral
S. Manirul Haque
P. Shanker
author_sort R. Singh Gujral
collection DOAJ
description An accurate and validated spectrophotometric method was developed for the determination of gabapentin. This is simple, sensitive and low cost UV spectrophotometric method. The method is based on the direct measurement of the native absorbance of the drug. The detection was done at 210 nm. The method was linear in the range of 0.25 - 3.5 µ g/mL with correlation coefficient of 0.9999. It is validated according to the ICH guidelines with respect to linearity, selectivity, accuracy and precision, limit of quantitation and limit of detection. The method has been applied to assess gabapentin in pharmaceutical formulations with good accuracy and precision and relatively free of interference from coexisting substances.
format Article
id doaj-art-d9a1dd3d25cb4241bdacf7ecd608bf68
institution Kabale University
issn 0973-4945
2090-9810
language English
publishDate 2009-01-01
publisher Wiley
record_format Article
series E-Journal of Chemistry
spelling doaj-art-d9a1dd3d25cb4241bdacf7ecd608bf682025-08-20T03:24:22ZengWileyE-Journal of Chemistry0973-49452090-98102009-01-016S1S163S17010.1155/2009/451967A Sensitive UV Spectrophotometric Method for the Determination of GabapentinR. Singh Gujral0S. Manirul Haque1P. Shanker2Vardhman Chemtech Ltd, Nimbua, Dera Bassi, Mohali (Punjab), IndiaVardhman Chemtech Ltd, Nimbua, Dera Bassi, Mohali (Punjab), IndiaVardhman Chemtech Ltd, Nimbua, Dera Bassi, Mohali (Punjab), IndiaAn accurate and validated spectrophotometric method was developed for the determination of gabapentin. This is simple, sensitive and low cost UV spectrophotometric method. The method is based on the direct measurement of the native absorbance of the drug. The detection was done at 210 nm. The method was linear in the range of 0.25 - 3.5 µ g/mL with correlation coefficient of 0.9999. It is validated according to the ICH guidelines with respect to linearity, selectivity, accuracy and precision, limit of quantitation and limit of detection. The method has been applied to assess gabapentin in pharmaceutical formulations with good accuracy and precision and relatively free of interference from coexisting substances.http://dx.doi.org/10.1155/2009/451967
spellingShingle R. Singh Gujral
S. Manirul Haque
P. Shanker
A Sensitive UV Spectrophotometric Method for the Determination of Gabapentin
E-Journal of Chemistry
title A Sensitive UV Spectrophotometric Method for the Determination of Gabapentin
title_full A Sensitive UV Spectrophotometric Method for the Determination of Gabapentin
title_fullStr A Sensitive UV Spectrophotometric Method for the Determination of Gabapentin
title_full_unstemmed A Sensitive UV Spectrophotometric Method for the Determination of Gabapentin
title_short A Sensitive UV Spectrophotometric Method for the Determination of Gabapentin
title_sort sensitive uv spectrophotometric method for the determination of gabapentin
url http://dx.doi.org/10.1155/2009/451967
work_keys_str_mv AT rsinghgujral asensitiveuvspectrophotometricmethodforthedeterminationofgabapentin
AT smanirulhaque asensitiveuvspectrophotometricmethodforthedeterminationofgabapentin
AT pshanker asensitiveuvspectrophotometricmethodforthedeterminationofgabapentin
AT rsinghgujral sensitiveuvspectrophotometricmethodforthedeterminationofgabapentin
AT smanirulhaque sensitiveuvspectrophotometricmethodforthedeterminationofgabapentin
AT pshanker sensitiveuvspectrophotometricmethodforthedeterminationofgabapentin