Effect of sterilization methods on the absorption capacity of absorbent paper points

The purpose of the present study was to analyze the influence of sterilization methods on the absorption capacity of different brands of standardized absorbent paper points, testing the hypothesis that there is a positive correlation between the percentage of increased absorption capacity and steril...

Full description

Saved in:
Bibliographic Details
Main Authors: Carlos Menezes Aguiar, Thaísa Torres, Daniela Mendes, Bruna Farias, Andréa Cruz Câmara
Format: Article
Language:English
Published: Universidade Estadual Paulista 2012-09-01
Series:Brazilian Dental Science
Online Access:https://ojs.ict.unesp.br/index.php/cob/article/view/737
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849228687739715584
author Carlos Menezes Aguiar
Thaísa Torres
Daniela Mendes
Bruna Farias
Andréa Cruz Câmara
author_facet Carlos Menezes Aguiar
Thaísa Torres
Daniela Mendes
Bruna Farias
Andréa Cruz Câmara
author_sort Carlos Menezes Aguiar
collection DOAJ
description The purpose of the present study was to analyze the influence of sterilization methods on the absorption capacity of different brands of standardized absorbent paper points, testing the hypothesis that there is a positive correlation between the percentage of increased absorption capacity and sterilization method. Standardized endodontic absorbent paper points (size rank from #15 to #40) from three different brands of three manufacturers were used for this study (Dentsply, Endopoints, Tanari). Twenty absorbent paper points of each size were used. The initial weight (iw) of each absorbent paper point was recorded using a digital scale. After sterilization, the dry weight (dw) of each absorbent paper point was determined. Each paper point was then introduced into a 2% methylene blue solution during 20 seconds until complete saturation. The paper points were removed from the solution and the wet weight (ww) was determined, with absorption capacity calculated from a difference between ww-dw. Data was statistically analyzed using Tukey’s test and the Student’s t-test (p<0.05). Tanari paper points exhibited the best absorption capacity among the brands analyzed, but the difference was non-significant. Sterilization process did not influence the absorption capacity of absorbent paper points.
format Article
id doaj-art-d94cab9818ce43f9bee0cf50bc88c28c
institution Kabale University
issn 2178-6011
language English
publishDate 2012-09-01
publisher Universidade Estadual Paulista
record_format Article
series Brazilian Dental Science
spelling doaj-art-d94cab9818ce43f9bee0cf50bc88c28c2025-08-22T17:56:39ZengUniversidade Estadual PaulistaBrazilian Dental Science2178-60112012-09-0115110.14295/bds.2012.v15i1.737Effect of sterilization methods on the absorption capacity of absorbent paper pointsCarlos Menezes Aguiar0Thaísa TorresDaniela MendesBruna FariasAndréa Cruz Câmara1Universidade Federal de PernambucoUFPEThe purpose of the present study was to analyze the influence of sterilization methods on the absorption capacity of different brands of standardized absorbent paper points, testing the hypothesis that there is a positive correlation between the percentage of increased absorption capacity and sterilization method. Standardized endodontic absorbent paper points (size rank from #15 to #40) from three different brands of three manufacturers were used for this study (Dentsply, Endopoints, Tanari). Twenty absorbent paper points of each size were used. The initial weight (iw) of each absorbent paper point was recorded using a digital scale. After sterilization, the dry weight (dw) of each absorbent paper point was determined. Each paper point was then introduced into a 2% methylene blue solution during 20 seconds until complete saturation. The paper points were removed from the solution and the wet weight (ww) was determined, with absorption capacity calculated from a difference between ww-dw. Data was statistically analyzed using Tukey’s test and the Student’s t-test (p<0.05). Tanari paper points exhibited the best absorption capacity among the brands analyzed, but the difference was non-significant. Sterilization process did not influence the absorption capacity of absorbent paper points.https://ojs.ict.unesp.br/index.php/cob/article/view/737
spellingShingle Carlos Menezes Aguiar
Thaísa Torres
Daniela Mendes
Bruna Farias
Andréa Cruz Câmara
Effect of sterilization methods on the absorption capacity of absorbent paper points
Brazilian Dental Science
title Effect of sterilization methods on the absorption capacity of absorbent paper points
title_full Effect of sterilization methods on the absorption capacity of absorbent paper points
title_fullStr Effect of sterilization methods on the absorption capacity of absorbent paper points
title_full_unstemmed Effect of sterilization methods on the absorption capacity of absorbent paper points
title_short Effect of sterilization methods on the absorption capacity of absorbent paper points
title_sort effect of sterilization methods on the absorption capacity of absorbent paper points
url https://ojs.ict.unesp.br/index.php/cob/article/view/737
work_keys_str_mv AT carlosmenezesaguiar effectofsterilizationmethodsontheabsorptioncapacityofabsorbentpaperpoints
AT thaisatorres effectofsterilizationmethodsontheabsorptioncapacityofabsorbentpaperpoints
AT danielamendes effectofsterilizationmethodsontheabsorptioncapacityofabsorbentpaperpoints
AT brunafarias effectofsterilizationmethodsontheabsorptioncapacityofabsorbentpaperpoints
AT andreacruzcamara effectofsterilizationmethodsontheabsorptioncapacityofabsorbentpaperpoints