Results of type testing of MTS-N dosimeters with IEC 62387:2012 standard at the laboratory of external dosimetry in Nicaragua
This study presents the results of the verification of the method according to working procedures of the Laboratory of External Dosimetry (LDE) located at the Laboratory of Radiation Physics and Metrology (LAF-RAM), which is the only Individual Monitoring service provider in Nicaragua. The test is c...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)
2022-07-01
|
| Series: | Brazilian Journal of Radiation Sciences |
| Subjects: | |
| Online Access: | https://bjrs.org.br/revista/index.php/REVISTA/article/view/2029 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850104166640254976 |
|---|---|
| author | Andrea Castillo Norma Roas |
| author_facet | Andrea Castillo Norma Roas |
| author_sort | Andrea Castillo |
| collection | DOAJ |
| description | This study presents the results of the verification of the method according to working procedures of the Laboratory of External Dosimetry (LDE) located at the Laboratory of Radiation Physics and Metrology (LAF-RAM), which is the only Individual Monitoring service provider in Nicaragua. The test is considered as validation of the method since the LAF-RAM follows a Quality Management System. The chosen performance testing according to IEC 62387:2012 are Coefficient of variation, Non linearity, Radiation energy and angle of incidence, Dosimeter droop, Light exposure (reader), Over-response of radiation incidence and Build up, fading, self-irradiance and natural radiation response. The results in general show that all test are in compliance with the requirements except for some temporal conditions in Buildup, fading, self-irradiance test. |
| format | Article |
| id | doaj-art-d9182c5c919a48aa8f55b7d3cf4c133e |
| institution | DOAJ |
| issn | 2319-0612 |
| language | English |
| publishDate | 2022-07-01 |
| publisher | Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR) |
| record_format | Article |
| series | Brazilian Journal of Radiation Sciences |
| spelling | doaj-art-d9182c5c919a48aa8f55b7d3cf4c133e2025-08-20T02:39:23ZengBrazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)Brazilian Journal of Radiation Sciences2319-06122022-07-01102A (Suppl.)10.15392/bjrs.v10i2A.20291647Results of type testing of MTS-N dosimeters with IEC 62387:2012 standard at the laboratory of external dosimetry in NicaraguaAndrea Castillo0Norma RoasUniversidad Nacional Autónoma de Nicaragua, ManaguaThis study presents the results of the verification of the method according to working procedures of the Laboratory of External Dosimetry (LDE) located at the Laboratory of Radiation Physics and Metrology (LAF-RAM), which is the only Individual Monitoring service provider in Nicaragua. The test is considered as validation of the method since the LAF-RAM follows a Quality Management System. The chosen performance testing according to IEC 62387:2012 are Coefficient of variation, Non linearity, Radiation energy and angle of incidence, Dosimeter droop, Light exposure (reader), Over-response of radiation incidence and Build up, fading, self-irradiance and natural radiation response. The results in general show that all test are in compliance with the requirements except for some temporal conditions in Buildup, fading, self-irradiance test.https://bjrs.org.br/revista/index.php/REVISTA/article/view/2029dose response, requirement, type testing |
| spellingShingle | Andrea Castillo Norma Roas Results of type testing of MTS-N dosimeters with IEC 62387:2012 standard at the laboratory of external dosimetry in Nicaragua Brazilian Journal of Radiation Sciences dose response, requirement, type testing |
| title | Results of type testing of MTS-N dosimeters with IEC 62387:2012 standard at the laboratory of external dosimetry in Nicaragua |
| title_full | Results of type testing of MTS-N dosimeters with IEC 62387:2012 standard at the laboratory of external dosimetry in Nicaragua |
| title_fullStr | Results of type testing of MTS-N dosimeters with IEC 62387:2012 standard at the laboratory of external dosimetry in Nicaragua |
| title_full_unstemmed | Results of type testing of MTS-N dosimeters with IEC 62387:2012 standard at the laboratory of external dosimetry in Nicaragua |
| title_short | Results of type testing of MTS-N dosimeters with IEC 62387:2012 standard at the laboratory of external dosimetry in Nicaragua |
| title_sort | results of type testing of mts n dosimeters with iec 62387 2012 standard at the laboratory of external dosimetry in nicaragua |
| topic | dose response, requirement, type testing |
| url | https://bjrs.org.br/revista/index.php/REVISTA/article/view/2029 |
| work_keys_str_mv | AT andreacastillo resultsoftypetestingofmtsndosimeterswithiec623872012standardatthelaboratoryofexternaldosimetryinnicaragua AT normaroas resultsoftypetestingofmtsndosimeterswithiec623872012standardatthelaboratoryofexternaldosimetryinnicaragua |